Abstract

What does a buyer learn from “TL-30”, “Group 1R” or a red GSA label? Each answers a different question. A UL 687 class is a laboratory threshold: the safe resisted prepared testers with a defined tool set for the stated net minutes, on the door and front face or, for X6 classes, on all six sides. It is not a measured time to breach in the field. UL 768 grades a mechanical combination lock alone, by its resistance to being opened through sight, touch or hearing and, for Group 1R, radiography. A GSA Class 5 or Class 6 cabinet is tested against 20 man-hours of surreptitious entry and 30 man-minutes of covert entry, and Class 6 has no forced-entry requirement. For Top Secret in such a container, 32 CFR 2001.43 adds one supplemental control: inspection every two hours, an alarm with responders arriving within 15 minutes, or security-in-depth with an FF-L-2740 lock. Apart from some federal cabinets whose approval depends on mounting to the maker’s instructions, the ratings do not cover installation, and none covers combination management or later-found design flaws, as published 2016 and 2025 attacks on specific electronic safe locks that the researchers describe as certified show.

Three promises on one door

A specification that calls for “a TL-30 safe with a UL 768 Group 1R lock”, and another that calls for “a GSA-approved Class 5 container with an FF-L-2740B lock”, read as two versions of the same idea: a strong steel box with a good lock. They are not. The first describes a commercial product tested by UL against a defined burglary attack and fitted with a separately tested lock. The second describes government equipment, tested by the government, bought through a controlled federal supply channel, and allowed to hold classified information only inside a regulatory system that, for Top Secret, adds inspection, alarm response or security-in-depth.

Three distinct claims are in play:

  • A UL 687 class such as TL-30 names an attack (tools, torches or explosives), the surfaces attacked (door and front face, or door and body) and a duration.1
  • A UL 768 group such as Group 1R concerns the lock alone. UL 768 tests the ability of combination locks “to resist unauthorized opening of the combination locks by sense of sight, touch, or hearing”, and it does not cover electronic locks.2
  • A GSA class such as Class 5 or Class 6 is defined by man-hours of surreptitious entry, man-minutes of covert entry and, for some classes only, man-minutes of forced entry.3

The design question behind all of them, how much delay a facility needs and against whom, belongs to the risk assessment covered in How a facility’s security is decided. Door hardware ratings are a separate subject.

UL 687: burglary-resistant safes

The classes

UL 687, the Standard for Burglary-Resistant Safes, is in its fifteenth edition, published on 19 July 2011; UL’s catalogue records a reaffirmation as an American National Standard dated 1 July 2025, with “No technical changes”.1 Its scope covers “combination locked burglary-resistant safes” and divides them by where the testers attack. “Test attack against the door and front face” covers TL-15, a tool-resistant deposit safe, TL-30 and TRTL-30. “Test attack against the door and body” covers TL-15X6, TL-30X6, TRTL-15X6, TRTL-30X6, TRTL-60X6 and the “Torch-, Explosive-, and Tool-Resistant Safe – Class TXTL-60X6”. Night depositories are excluded and covered by UL 771.1

The letters name the attack: TL for tools, TRTL for torch and tools, TXTL for torch, explosives and tools; the number is the duration in minutes. A jewellers’ insurer abbreviates the difference as “a TL-30 safe is tool resistant for 30 minutes, on the door only”, against “all six sides” for TRTL-30x6.4 UL’s own wording is more precise: the non-X6 classes are attacked on the door and front face.1 The class names the surfaces the testers were allowed to attack. The standard’s construction requirements for the rest of the body are not public, so the class label alone says nothing either way about the strength of the back or sides.

What the test is

UL describes its own work only in outline. Its technicians “analyze the blueprints to a commercial safe to identify the weak points and plan out where and how to attack it”, and the aim is “to create an opening that’s large enough to remove its contents or pry open the door within a specified period of time”.5 For its most basic test UL lists “hand tools, picking tools, mechanical or electrical tools, grinding points, carbide drills and devices that apply pressure”, used for 15 minutes; at the top of the range the tool set adds “cutting devices, such as power saws and high-level explosives like nitroglycerin”.5 UL says it tested its first safe for burglary resistance in 1923 and its first bank vault in 1925.5

The test details are in the paid standard, not in any public UL text. Safe dealers fill the gap. One dealer describes the clock as net working time: “when the tool comes off the safe, the clock stops”.6 The same dealer summarises construction requirements (lock type, a minimum weight or anchoring, and body-wall strength) that differ between classes; its figures cannot be checked against public UL text and are not repeated here.6 UL’s own catalogue confirms only that such criteria are within the standard’s subject matter: a 2007 meeting of the standards technical panel listed “Defining Comparison Test Results to 1 Inch Thick Steel with an Ultimate Tensile Strength of 50,000 PSI” and “Further Defining Anchoring Methods for TL-15 and Deposit Safes” among its topics.2 A contract that depends on construction or anchoring details should quote the standard itself.

What sits below UL 687

UL Solutions tests “residential security containers — commonly known as gun safes” under UL 1037, the standard for antitheft alarms and devices, at three levels: a five-minute attack by one technician with common hand tools; a ten-minute attack by two technicians with carbide drills and pressure devices, including attempts to make “a six-square-inch opening in the door or the front face”; and a ten-minute attack, again by two technicians, with more aggressive tools, in which the maximum opening shrinks to two square inches.7 8 Liberty Safe, a gun-safe maker, advises that for most homeowners “the most relevant UL burglary rating is the RSC”, and presents TL-15 and TL-30 as ratings for buyers seeking “commercial-grade security”.9

The insurance “construction” classes sit outside UL testing. The dealer quoted above calls B-rate and C-rate “construction standards: they describe how a safe is built, not how it performed in a test”, defines a C-rate box by its steel thickness, and says “NO tests are given to provide this rating”.6 Neither is a laboratory result, and both are best treated as trade shorthand.

Fire resistance is a separate matter with separate tests. UL’s fire test puts the safe in a furnace that reaches about 1,000°F in roughly five minutes; the label then gives a class for the maximum interior temperature (Class 350, for example) and a time rating, and an optional impact test drops the hot safe 30 feet. UL notes that burglary “is addressed with separate tests”.10 A fire label says nothing about burglary, and a TL label says nothing about fire.

The insurer quoted above advises jewellers to choose a rated safe, to check that the floor can carry it and to keep it off exterior or common walls.4 The dealer’s page separates its own coverage guidance for B-rate, C-rate and RSC safes, based on its conversations with underwriters, from a table of suggested content values for UL classes that it attributes to the insurer’s published guidelines, conditional on the insurer’s alarm requirements.6 On the dealer’s account, then, underwriting looks at the alarm as well as the safe.

UL 768: the combination lock

Groups 2, 1 and 1R

UL 768, the Standard for Combination Locks, covers “combination locks intended for attachment on doors of safes, chests, vaults, and the like, to provide a means of locking the boltwork against unauthorized opening”. It is in its eighth edition, published on 6 January 2006, last revised and ANSI-approved on 22 August 2023; the scope states that locks covered “may or may not have integral protection against entry by force” and that “these requirements do not cover electronic locks”.2 Key locks on doors are rated under different standards, covered in What a lock rating promises.

The most detailed public description of the groups is a 1989 military handbook. It says UL 768 “classifies mounted combination locks as either Group 1, Group 1R, or Group 2”, that “to qualify for a Group 1R rating, a lock must be manipulation, radiographic, and thermal resistant”, and that “Group 2 combination locks must be reasonably resistant to unauthorized opening”.11 It also describes the locks of its day: Group 1 locks had brass wheels and Group 1R locks “X-ray proof (Delrin) wheels”, and the locks it covered had a thermal relocker and a relocking trigger that deadlocks the unit if the spindle is punched.11 Those descriptions date from 1989 and may not match current products.

Manipulation and the 20-hour figure

Manipulation means opening a combination lock by working the dial and inferring the combination from the mechanism’s feedback, without damage; UL 768’s scope frames it as opening “by sense of sight, touch, or hearing”.2 It is the combination-lock counterpart of picking, whose mechanics for pin tumbler locks are covered in How pin tumbler locks are opened. A radiological attack reads the positions of the wheels by radiography, which is why the 1R group exists.11

The exact Group 1 manipulation requirement is not given in any public source consulted. The closest government statement concerns a federal lock: the DoD Lock Program says that locks to Federal Specification FF-L-2937 “meet performance and design requirements of UL Standard 768, Group 1” and “resist manual manipulation for a period of 20 man hours”.12

Electronic safe locks

Because UL 768 excludes electronic locks, UL evaluates them under a separate document, UL 2058, the Outline of Investigation for High-Security Electronic Locks.2 13 Researchers and dealers refer to locks evaluated this way as UL “Type 1” high-security electronic locks.14 6 Whether a given model holds a current listing is a model-level question for UL’s certification directory, not something a brochure can settle.

The federal system

Who sets the standard

Under 32 CFR 2001.42(a), the Administrator of General Services, “in coordination with agency heads originating classified information”, establishes and publishes “uniform standards, specifications, qualified product lists or databases, and supply schedules” for security equipment that stores classified information.15 It works through the Interagency Advisory Committee on Security Equipment (IACSE), which GSA chairs and which “develops and maintains security equipment standards, qualified products lists (QPL), and procurement guidance”.16 The specifications and qualified products lists are published by the DoD Lock Program at the Naval Facilities Engineering and Expeditionary Warfare Center.17

The current base documents, with their latest listed amendments, are these:17

  • AA-F-358K (16 February 2023): filing cabinets, legal and letter size, uninsulated, security. Classes 5, 5-S, 5-W, 6 and 6-S.
  • AA-F-363D (1 June 2001, Amendment 4 of 6 April 2015): map and plan cabinets.
  • AA-C-2786A (3 June 2020): information processing system (IPS) cabinets, Class 5.
  • AA-C-2859A (20 April 2007): weapons storage cabinets.
  • AA-D-600D (15 May 2000, Amendment 4 of 5 January 2010): vault doors.
  • AA-V-2737 (25 April 1990, Amendment 3 of 25 February 2013): modular vault systems.
  • FF-L-2740B (15 June 2011, Amendment 2 of 21 August 2018): electromechanical combination locks.
  • FF-L-2937 (31 January 2005, Amendment 2 of 1 February 2007): mechanical combination locks.
  • FF-L-2938 (17 August 2022): electromechanical combination locks for US allies.
  • FF-L-2890C (22 February 2019): lock extensions, that is, pedestrian door lock assemblies, panic assemblies and auxiliary deadbolts.

Two federal standards sit beside them: FED-STD-832 for vault construction and FED-STD-809E for inspection, maintenance, neutralization and repair. The amendments listed above are cited from the index; requirements quoted below come from the base texts.

Classes 5 and 6

AA-F-358K defines the filing cabinet classes by three kinds of entry. Class 5 resists “20 man-hours surreptitious entry, 30 man-minutes covert entry and 10 man-minutes forced entry”; Class 6 resists the same surreptitious and covert entry with “No forced entry requirements”; Class 5-W, the weapons variant, resists only “10 man-minutes forced entry”.3 Under section 4.6.12 the cabinet is radiographed, and the radiographs “shall not permit determination of the lock combination to the extent that entry is made into the cabinet in less than the time specified”, 20 man-hours, a requirement that does not apply to weapons containers.3 The map and plan specification gives its Class 5 the same three figures, and the vault door specification defines Class 5-V (20 man-hours surreptitious, 30 man-minutes covert, 10 man-minutes forced), Class 5-A armory doors (30 man-minutes covert and 10 man-minutes forced) and Class 5-B ballistic doors (5-V plus ballistic resistance).18 19

FF-L-2740B supplies the definitions. Covert entry causes damage that can be repaired so that it “would not be detectable by a user during normal use” but “would be detectable during inspection by a qualified person”. Surreptitious entry is “a method of entry, such as manipulation or radiological attack, which would not be detectable during normal use or during inspection by a qualified person”.20 The classes are therefore graded by how detectable an entry would be under the laboratory’s definitions, with the longest requirement for the entry that a qualified inspector would not find. The specifications do not explain why those thresholds were chosen, and a laboratory definition of “detectable” does not guarantee that anyone will inspect a given container in time.

The AA-F-358K test conditions differ from UL’s. Testers get “sufficient time and opportunity to study the design and construction of the cabinet and to develop testing methods prior to the start of testing”, and “There shall be no limit to the number of methods” of entry attempted; not more than two people work simultaneously during each attempt; and the man-minute working time excludes time for safety precautions and rest periods.3 All the tools for a test must fit in two cases of no more than 1.5 cubic feet each and weigh no more than 150 pounds in total; within those limits, the types of tool for surreptitious entry are “unlimited”. For covert entry, drills are limited to commercially available units of no more than 5,000 rpm, pressure rigs to a 30-inch lever and heat to single-tank propane, butane or equivalent, with acetylene, MAPP, burn bars, oxidizer-assisted products and explosives excluded. Forced-entry testing is limited to “non-powered tools only”.3 The clock starts “when the test equipment is picked up to approach the sample”, and any change or repair of tools happens while it runs.3 On these terms a Class 5 cabinet is tested against a well-prepared opener with portable equipment and against a short attack with hand tools, not against the power saws and torches of the upper UL classes.

The lock: FF-L-2740 and its siblings

In the DoD Lock Program’s account, robotic dialing of mechanical combination locks “drove the General Services Administration (GSA) to create the first Federal specification for ‘Locks, Combination,’ FF-L-2740, on 12 October 1989”, and the first lock approved under it was the Mas-Hamilton Model X-07, an electromechanical lock.21 FF-L-2740A followed on 12 January 1997, and FF-L-2740B on 15 June 2011, titled “Locks, Combination, Electromechanical” because, the newsletter says, “a completely mechanical lock could not meet all requirements of the specification”.21 20

FF-L-2740B describes a lock “designed and manufactured specifically to protect unattended national security information (NSI)”. It must resist manipulation for 20 man-hours, radiological analysis for 20 man-hours and emanations analysis (sounds, latent display images or other signals) for 20 man-hours, and covert entry for 30 man-minutes.20 Amendment 2 of 21 August 2018 replaced the design section, and its paragraph 3.5.5 now requires at least 1,000,000 operational combinations.22 Its test method states: “Manipulation may include the use of automatic dialing devices”, and analysis may include “computer enhancement techniques for signals or emanations”.20 The specification addresses supply-chain risk directly: modern locks use “microprocessors with software codes that can be manipulated during manufacture and transportation”, and electronic components and software must be “accessed only by personnel subject to U.S. law”.20 Amendment 2 rewrote the software-security clause, 3.7.5. Manufacturers must submit a software security plan, give GSA documented source code and a tool to verify that approved firmware is loaded and unaltered, and obtain GSA’s written authorization before changing approved firmware. The amendment also requires that critical lock parameters such as the combination be stored “internal to the microcontroller” and that “The lock shall have no externally available communications interface to the firmware.”22 The government also “reserves the right of testing the combination lock in accordance with standards that are privileged to the Government”; the published requirements may not describe every test a lock faces.20

The specification defines two styles. A Style 1 lock is “Basic self-contained”: its power source must be self-generating and integral to the lock. A Style 2 lock is “Interoperable / networked”: its power source “may be contained within” the lock body or dial ring assembly and “may be replaceable and available in the open market”.20 Under Amendment 2, Style 1 locks “shall have no external data transfer ports”, and their audit data may be read only from the lock’s display; Style 2 locks may transfer data to secondary devices that monitor openings, access and combination changes, under applicable FIPS standards, but those devices “shall not be able to open the electromechanical lock”. The bar on an externally available firmware interface applies to both styles.22 GSA’s purchasing guide lists one lock of each: the Kaba Mas X-10 (Style 1, digital readout, no batteries) and the Sargent and Greenleaf 2740B (Style 2, battery-powered, with some networkability).23 Locks qualified under the specification may be sold only to the government and specifically authorized buyers.20

The other lock specifications have distinct scopes. FF-L-2937 covers a dial-operated mechanical lock that “cannot be opened by mechanical manipulation or autodialers for a period of 20 hours” and must not let autodialers dial 75 percent of usable combinations in that time.24 It is required on new GSA-approved weapons containers, armory vault doors and field safes, which “should not have an FF-L-2740 electromechanical combination lock”; existing units of those types may keep a working UL 768 Group 1 lock, but a failed one must be replaced with an FF-L-2937 lock.12 FF-L-2938 is an electromechanical lock “similar in design and manufacture” to FF-L-2740, for protecting US and foreign classified information provided to allied governments, and sold only to allies and authorized foreign liaison activities.25 FF-L-2890C covers pedestrian door locking hardware for use with changeable combination locks and strikes, designed to meet accessibility, building and fire codes.26

For security containers, the DoD Lock Program says: “There is no requirement to retrofit working locks on GSA-approved security containers with the GSA label still affixed.” If such a lock becomes unserviceable, the replacement must meet FF-L-2740B.27 The weapons and field-safe rule above is the exception.

Labels, and the end of the black label

The label is the approval. The DoD Lock Program says: “If the container no longer has the GSA label attached to it, it is no longer an approved container.” ISOO adds that the label “cannot be reproduced” and can be obtained only by original manufacturers or GSA-approved training institutions.27 16 Colour indicates generation: red labels on file cabinets, weapons containers and vault doors made since October 1990, blue on IPS cabinets, green on the discontinued Class 7, and black (black lettering on silver, or the reverse) on the older equipment.27 23

GSA-approved containers have been in use since 1954. ISOO Notice 2026-06 of 31 August 2026, which rescinded and consolidated five earlier notices including 2021-01 and 2022-03, says containers made before 1989 “are past their expected lifetime”, that many original makers are gone and parts unavailable, and that any container with a black label counts as a black-label container “regardless of the date of manufacture”.16 Approval is being withdrawn in stages that began on 1 October 2024. The notice’s table gives 1 October 2028 as end of service for black-label Class 1 cabinets under AA-F-357, Class 5 and Class 6 cabinets under AA-F-358 and Class 5 map and plan cabinets under AA-F-363, and 1 October 2035 for black-label Class 5 and Class 6 vault doors under AA-D-600.16 Black-label containers cannot be recertified or relabelled.27 FED-STD-809E draws the repair line by equipment type: a black-label file or map and plan cabinet that has been neutralized is “no longer authorized for the storage of classified information”, while “Black label vault doors may be neutralized and repaired until phased out in 2035”.28 At end of service, black-label equipment is searched, its labels are removed, its “limited-use” FF-L-2740B locks are removed and destroyed or returned to the U.S. Government, and it may then be repurposed as a general-purpose filing cabinet, but it must not go to a government reutilization programme and is ultimately sent to a steel recycler.16

The documents do not quite agree on the cut-off. ISOO’s table covers equipment “manufactured from 1954 through 1989”; the DoD Lock Program’s page dates black labels to containers made “before October 1990”.16 27 ISOO’s rule that the label colour decides makes the discrepancy mostly harmless.

Buying one

Classified information has not been storable in non-GSA-approved security containers since 1 October 2012, “unless otherwise authorized pursuant to 32 CFR 2001.40(b)”.16 That provision lets agency heads or their designees adopt “alternative measures, using risk management principles”, when necessary to meet operational requirements, provided they “reasonably deter and detect loss or unauthorized disclosure”. Measures used for other than temporary, unique situations must be documented and provided to the Director of ISOO. The provision does not apply to foreign government information.29

GSA’s June 2026 purchasing guide says: “Effective April 1, 2026, GSA is transitioning its GSA-Approved Security Container and Vault Door Program to offer brand name National Stock Numbers (NSNs)”. Orders go through GSA Global Supply, and “Exemptions to bypass GSA Global Supply are not permitted.”23 The guide does provide one route around the NSN catalogue: a buyer who needs “a specialized or non-standard security cabinet or vault door that is not currently covered by an established NSN” may request a Direct Purchase Authority exemption, considered “on a case-by-case basis”.23 ISOO adds that IPS containers are bought through Global Supply by NSN or, “when an NSN is not assigned, purchased directly from the approved manufacturer”.16 Only manufacturers on the qualified products lists may sell the equipment, and resale through third-party programmes or unauthorized distributors or installers is prohibited.23

Repair, refurbishment and reuse are treated differently. Containers “reconditioned, refurbished, or remanufactured and obtained outside of the authorized GSA procurement processes” may not hold classified information, and containers sold to private parties through reutilization may not be refurbished, recertified and bought back as approved containers; but ISOO states that this “does not preclude the opening and repair of existing GSA approved security containers in accordance with Federal Standard 809”.16 Only GSA-authorized inspectors may recertify a container.23

The guide has already aged in one respect: it still cites ISOO Notices 2021-01 and 2022-03 for the black-label phase-out, which ISOO rescinded two months after the guide appeared.23 16 The two documents also list different second lock specifications. ISOO’s table of equipment in effect includes FF-L-2938, the electromechanical lock for allies, alongside FF-L-2740; the GSA guide’s lock table lists FF-L-2740 and FF-L-2937, the mechanical lock for weapons storage and field safes.16 23 They are different products for different uses, so a specification should name the lock by its own specification and revision.

Approval can also be lost by manufacturers. GSA removed Fedsafes, Inc. from the Class 5 qualified products list on 9 September 2017 “due to reoccurring inconsistent test results”, while leaving the approval of cabinets already in the field in place.27

Vaults

A vault for classified storage is built to FED-STD-832, which sets minimum construction requirements “for high security vaults for storage of classified information and weapons”.30 There are three classes. Class A vaults “offer the maximum protection against tool and torch attack”: walls, floor and ceiling of 8-inch (200 mm) reinforced concrete with 5/8-inch rebar at 6 inches on centre each way, and a door and frame to AA-D-600, Class 5. Section 5.2 requires a Class B vault to conform to the modular vault specification AA-V-2737. Class C vaults, also less than maximum protection, are for locations where structural circumstances do not permit concrete construction.30 For Class A, openings larger than 96 square inches and over 6 inches in their smallest dimension need barriers of 9-gauge expanded metal or half-inch steel bars, with solid caulking “to give evidence of surreptitious entry attempt”.30

Open storage areas, rooms in which classified material may be held outside containers, are built to 32 CFR 2001.53.31 Walls, floor and ceiling must be permanently constructed and attached, “in a manner as to provide visual evidence of unauthorized penetration”. Entrance doors take “a built-in GSA-approved three-position combination lock”, although for Secret and Confidential storage the agency head may authorize other locks in special circumstances. Vents and ducts over 96 square inches and over 6 inches in their smallest dimension need bars, grilles, baffles or an alarm. Windows within 18 feet of the ground need forced-entry protection, except that open storage areas inside a controlled compound or equivalent may drop it if the windows are made inoperable and covered by an alarm.31

Opening and repair

Equipment that is meant to be inspected must also be openable when a combination is lost or a lock fails. FED-STD-809E sets out the authorized opening and repair methods and the training required of the people who use them; “To maintain the GSA label on a container or vault door, one of the following procedures must be used for opening and repair”, and departures from the specified methods need an approved exemption.28 Both 32 CFR 2001.43(e) and 32 CFR 117.15(b) require neutralization and repair of GSA-approved containers and vault doors to follow FED-STD-809.32 33

How classified storage is specified: 32 CFR 2001.43 and 117.15

The rule

The storage rule for executive-branch agencies opens with its purpose: classified information “shall be stored only under conditions designed to deter and detect unauthorized access”.32 For Top Secret, the container must be a GSA-approved security container, a vault built to FED-STD-832, or an open storage area built to 2001.53, and supplemental controls are required. For a GSA-approved container, one of three is enough:32

  1. “Inspection of the container every two hours by an employee cleared at least to the Secret level”;
  2. an intrusion detection system “with the personnel responding to the alarm arriving within 15 minutes of the alarm annunciation”; or
  3. “Security-In-Depth coverage of the area in which the container is located, provided the container is equipped with a lock meeting Federal Specification FF-L-2740.”

Top Secret open storage covered by security-in-depth needs an alarm with a 15-minute response; open storage not covered by security-in-depth needs responders who “shall arrive within five minutes of the alarm annunciation”.32 For Top Secret, ISOO has stated that these supplemental controls apply to vaults built to FED-STD-832 as well as to GSA-approved containers, and that intrusion detection equipment is acceptable when tested and labelled by an OSHA-recognised nationally recognised testing laboratory to ANSI/UL standards.16

Secret is stored the same way as Top Secret. The rule’s text still mentions non-GSA-approved containers, but only “until October 1, 2012”; since then the alternative-measures route of 2001.40(b) is the only exception.32 29 Security-in-depth is required wherever a non-GSA-approved container or an open storage area holds Secret, and, except for storage in a GSA-approved container or a FED-STD-832 vault, one supplemental control is required: inspection every four hours by an employee cleared at least to Secret, or an alarm with responders arriving within 30 minutes.32 Confidential is stored as Top Secret or Secret, without supplemental controls.32

Security-in-depth is defined as “a determination by the agency head that a facility’s security program consists of layered and complementary security controls sufficient to deter and detect unauthorized entry and movement within the facility”, with fences, access controls, alarms, random guard patrols and video as examples.34 The layered-perimeter thinking behind that definition is the subject of Designing out crime.

The rule also governs combinations. They are changed only by “persons authorized access to the level of information protected unless other sufficient controls exist to prevent access to the lock or knowledge of the combination”. They must be changed when the equipment is placed into use; when a person knowing the combination no longer needs access, “unless other sufficient controls exist to prevent access to the lock”; and whenever a combination “has been subject to possible unauthorized disclosure”.32 When equipment is taken out of service, the lock “should be reset” to 50-25-50 for built-in locks or 10-20-30 for padlocks.32 Key-operated locks are allowed for Secret and Confidential only when the agency head approves them in special circumstances, with key and lock accounting.32

Contractors

For cleared contractors, 32 CFR 117.15 applies the same storage options and the 2001.43 supplemental controls.33 Its paragraph (d) sets minimum standards for an approved intrusion detection system “when used for supplemental protection of TOP SECRET and SECRET material”. For such a system, the cognizant security agency must approve it before installation, basing approval on Intelligence Community Directive 705, UL 2050 or its own written standards; equipment not tested and listed by a nationally recognised testing laboratory needs the agency’s approval; the system “must be activated at the close of business whenever the area is not occupied by cleared personnel”; and the alarmed area must cover “all points of probable entry” with contacts and motion detectors “positioned in the probable intruder paths”.33 In the same installation requirements, the contractor rule states that “In accordance with Federal Standard 809, no IDS sensors (magnetic contacts or vibration detectors) will be installed on GSA-approved security containers”.33 Combinations to approved vaults, open storage areas and containers are protected at the level of the most sensitive information they guard.33

What the rule is saying

The regulation and the specifications measure different things. AA-F-358K states laboratory resistance in man-minutes and man-hours under its own test conditions; 2001.43 states an inspection interval in hours and a response time in elapsed minutes after the alarm sounds.3 32 Neither document converts one into the other, and a test result is not a guarantee of field delay. As an engineering reading, though, the structure is clear: the container is one layer, and the rule pairs it with someone who looks, someone who comes or a building layered enough to slow an intruder before the container is reached. Where there is no container at all (Top Secret open storage without security-in-depth), the allowed response falls to five minutes.32

The ratings side by side

RatingWho defines and certifiesWhat is attackedTools and conditionsTimeWhat a pass means
UL 687 TL-15, TL-301 5UL standard; UL tests and listsDoor and front faceTools only; UL lists hand, picking, mechanical and electrical tools, grinding points, carbide drills and pressure devices for its basic test; testers study the drawings15 or 30 minutesTesters did not achieve entry as the standard defines it within the time
UL 687 TRTL-301UL standard; UL tests and listsDoor and front faceTools and torches30 minutesAs defined in the standard, against torch and tool attack
UL 687 X6 classes1 5UL standard; UL tests and listsDoor and bodyTL-X6: tools; TRTL-X6: torches and tools; TXTL-60X6: torches, explosives and tools15, 30 or 60 minutesAs defined in the standard, on door and body
UL 1037 RSC levels7 8UL standard; UL testsLevel 1: the product; level 2: opening attempt on the door or front face; level 3: opening limit of two square inchesLevel 1: one technician, common hand tools; level 2: two technicians, picks, carbide drills, pressure devices; level 3: two technicians, more aggressive toolsLevel 1: 5 minutes; levels 2 and 3: 10 minutesLevel 1: product withstands the attack; level 2: no six-square-inch opening; level 3: no opening beyond two square inches
UL 768 Group 2, 1, 1R2 11UL standard; UL tests and listsA mechanical combination lockOpening by sight, touch or hearing; Group 1R also radiography and thermal attackNot in the public sourcesLock met the group’s requirements
GSA Class 5 (AA-F-358K)3GSA via IACSE; government test; qualified products listCabinet and lockAll tools within two cases of 1.5 cubic feet and 150 pounds; surreptitious tool types otherwise unlimited; covert tools also limited by drill speed and heat source; forced entry with non-powered tools20 man-hours surreptitious, 30 man-minutes covert, 10 man-minutes forcedNo entry within the class times under the test conditions
GSA Class 6 (AA-F-358K)3GSA via IACSE; government test; qualified products listCabinet and lockAll tools within two cases of 1.5 cubic feet and 150 pounds; surreptitious tool types otherwise unlimited; covert tools also limited by drill speed and heat source20 man-hours surreptitious, 30 man-minutes covert; no forced-entry requirementNo surreptitious or covert entry within the class times
FF-L-2740B lock20GSA; published tests plus a reserved right to privileged testingThe lockManipulation including autodialers, radiological and emanations analysis; covert entry limited to dial and spindle20 man-hours for each surreptitious method; 30 man-minutes covertLock qualified for approved containers, vault doors and pedestrian door deadbolts
FED-STD-832 Class A vault30GSA construction standardThe roomConstruction requirements, not an attack testNot applicable8-inch reinforced concrete shell, AA-D-600 Class 5 door, barriers on large openings

What a rating does not tell you

Laboratory minutes are not field minutes

A UL time is a test threshold for testers who have studied the product. The dealer quoted above warns that the net times “are often thought to be the amount of time it takes to break into a safe”, calls that belief false, and says that its own technicians, opening safes legally, often take one to eight hours.6 That is one firm’s account of its own work, not a study of burglaries. The rating tells a buyer what happened in a controlled test, and no public source quoted here measures how real attacks compare with it.

The federal tests state their assumptions: preparation time before testing, no limit on the number of methods, and a clock that starts when the tester picks up the tools.3 A Class 6 cabinet carries no forced-entry requirement, so the test sets no threshold for its resistance to force and says nothing about it.3 The storage rule does not necessarily make up the difference: Secret in a GSA-approved container or FED-STD-832 vault needs no supplemental control, and Confidential needs none in any approved storage.32 For those levels, protection against force depends on the facility around the container.

Electronic locks: what published research found

For mechanical dials, the federal record shows one attack forcing a redesign: robotic dialing of mechanical locks led to FF-L-2740 in 1989.21 The current federal tests treat automatic dialing and computer-enhanced signal analysis as standard tools, and FF-L-2937 builds an autodialer criterion into its pass condition.20 24

Two published studies of commercial electronic safe locks reported weaknesses in specific models that the researchers describe as certified; the official listing status of each tested unit is not documented here. At DEF CON 24 in 2016 a researcher presenting as Plore reported side-channel attacks on two Sargent and Greenleaf locks that the slides describe as UL-listed Type 1 high-security electronic locks.14 For the S&G 6120, which the slides say was designed and certified around 1994 and still produced at least into late 2015, the researcher reported recovering the code from electrical measurements, from outside the safe and without visible tampering. For the newer Titan PivotBolt, the researcher reported a timing weakness in code checking and a way around the lockout, reducing the expected time from about 3.8 years of brute force to about 15 minutes.14 The slides also say “Burglars aren’t going to bother with this”, point to FF-L-2740B as a specification that demands better design, and report attempts to contact S&G from February 2016 without “a useful response”.14 The findings apply to the models and versions tested.

At DEF CON 33 in August 2025, Mark Omo and James Rowley presented attacks on SecuRam ProLogic locks, which they describe as UL-certified high-security safe locks used in safes sold by Liberty Safe and other brands; the slides do not tie each tested unit to a listing.35 36 They began from the Liberty Safe episode of August 2023. Liberty Safe says it was served a search warrant that month, responded to it, and has since refined its policies on retaining codes and on responding to compulsory demands, including letting customers ask for their code to be deleted.37 From the slides:35

  • CodeSnatch. On the ProLogic firmware versions they analysed, the presenters reported that the lock’s master code was held in the keypad, outside the safe, and could be recovered through the keypad’s service interface with a small tool. They found no mitigation for installed locks other than a firmware update. SecuRam sent them a lock with newer firmware that appeared to remove keypad-side code storage, but they had not seen that version on sale; a retail lock they bought in July 2025, made in March 2025, had a different change, which they judged did not effectively mitigate the attack.
  • ResetHeist. The presenters reported that ProLogic’s locksmith recovery feature, intended to work only through a call to the factory, could be used by anyone to reset the lock’s codes, without tools. They give a defence: owners can change the lock’s recovery and encryption codes, which requires calling SecuRam. Their table lists tested units made between 2014 and 2025, including one comparator model that does not support recovery, and states that every lock they tested was vulnerable to ResetHeist.

The same slides limit their own claims. The researchers found SecuRam’s analog SafeLogic mode “actually fine”, with a theoretical timing weakness they could not exploit, and found “no evidence” of Chinese-government-mandated backdoors in the locks examined: “Bad Design ≠ Government Backdoors”.35 Their timeline records disclosure to SecuRam in March and April 2024, a reply in May 2024 threatening referral “to our counsel for trade libel”, and a later comment from SecuRam, referring to existing locksmith tools, that “The attack method you have indicated is not new”; they also note that SecuRam did not share mitigation plans or timelines with them.35 They concluded that standards for electronic physical security products lag well behind the state of the art.35 That is the researchers’ opinion from a sample of one vendor’s locks. The slides are not a survey of certified locks, and they do not show which tested units held which current listings.

Manufacturer reset codes raise a separate question. In a letter of 13 March 2024 to the National Counterintelligence and Security Center, Senator Ron Wyden wrote that many commercially available safes include electronic locks that “can also be unlocked using special codes set by and known only to the manufacturer”, that DoD had told his office on 8 November 2023 that such codes “pose a security threat and, consequently, are prohibited in the locks approved for U.S. government use”, and that Sargent and Greenleaf had confirmed many of its products include them while “the only S&G products that are approved to store U.S. government secrets do not feature such backdoor codes”.38 DoD’s written answers, attached to the letter, say the prohibition “is contained within the surreptitious entry and covert entry requirements and are not explicitly detailed”, and that “any master override mechanism would likely be a vulnerability, regardless of the lock type”.38 A commercial listing does not by itself tell a buyer whether a manufacturer, dealer or locksmith holds a code that opens the lock.

Uncertified and consumer locks

Plore’s slides set cheap, non-certified locks out of scope, noting that many can be brute-forced and some can be bypassed electrically or mechanically.14 At DEF CON 20 in 2012, Tobias, Bluzmanis and Fiddler presented small gun safes that, in their account, were represented as certified by the California Department of Justice yet could be opened by children, and listed the beliefs that lead buyers to trust such products, including that a “Product meets or exceeds standards” and that “Testing labs have certified the product”.39 The slides are the presenters’ account; they do not document each model’s regulatory status. In a separate case, the US Consumer Product Safety Commission announced on 22 February 2024 the recall of about 60,000 Awesafe biometric gun safes, after the firm received reports of 71 incidents of the safes “being opened by unauthorized users when the biometric lock failed to secure the safe”.40

Marketing language is not a listing

The UL 687 classes are a closed list.1 Wording such as “TL-rated”, “TL-30 equivalent” or “built to TL standards”, without a UL listing for the model, is not evidence that the model passed the test. A residential “RSC” container has passed a five- or ten-minute test under a different standard.7 B-rate and C-rate describe construction, not test results.6 A fire rating and a burglary rating come from separate tests.10 For GSA equipment the equivalent check is physical and documentary: a container without its label is not approved, black labels are being retired, containers reconditioned, refurbished or remanufactured and obtained outside authorized GSA procurement may not hold classified information, containers sold to private parties through reutilization may not be refurbished and bought back as approved, and authorized repair under FED-STD-809 remains allowed.27 16 23

Installation and anchoring

UL’s residential testing notes that products under 750 pounds may be drop-tested to simulate forced entry by impact, a test that “may not apply” if the product includes secure mounting provisions with clear installation instructions.7 Some federal cabinets make mounting a condition of approval: AA-F-358K requires special-size cabinets (except Class 6 Size VIII) and Class 6-S containers to be “mounted in accordance with manufacturer’s provided instructions in order to maintain GSA approval”, and special-size cabinets under 250 pounds must have mounting provisions.3 Whether a UL 687 class carries comparable weight or anchoring conditions is in the standard, not in public text; UL’s technical panel has discussed anchoring methods for TL-15 and deposit safes.2 The insurer’s advice concerns the building: check that the floor can carry the weight, and keep the safe off exterior and common walls.4 None of this appears on the label.

The federal system writes construction into the approval. A FED-STD-832 Class A vault is defined by its concrete, its rebar and its barred openings, and a Class C vault by its steel lining; an open storage area by walls that show penetration and by its window protection; and for contractors 117.15 requires the alarm design to cover probable entry points and intruder paths.30 31 33

What even the federal model leaves open

The government reserves the right to test locks against standards “privileged to the Government”, so outsiders cannot see every test a lock faces.20 DoD chose not to state the ban on reset codes explicitly; in Senator Wyden’s words, the government kept “the public in the dark about this vulnerability, after quietly protecting government agencies from it”.38 The black-label phase-out shows that approved equipment ages and that approval has to be withdrawn deliberately, over years.16 And the guidance documents drift: the GSA guide and the ISOO notice cite different notices and list different lock specifications, so a specifier has to work from the specifications themselves.23 16

Specifying a safe, vault or classified container

  1. Set the delay against a real response. As an engineering judgement, choose container resistance with the expected detection and response in mind; for classified storage, confirm which supplemental control in 2001.43 the site will use and that its interval or response time is met.32
  2. Check the exact class and surfaces. Confirm whether the class is a door-and-front-face class or an X6 class, and whether torches or explosives were part of the test.1
  3. Verify the model’s listing. Ask for the UL listing of the specific model and class, and treat “TL-rated” wording, RSC ratings and B- or C-rate descriptions as different claims.1 7 6
  4. Check fire and burglary separately. Confirm a fire class and duration if fire matters; a burglary class does not cover it.10
  5. Confirm the installation conditions. Check the manufacturer’s mounting instructions and any weight or anchoring condition that applies to the model’s rating, including the AA-F-358K mounting condition for special-size and Class 6-S cabinets, and have floor loading checked for heavy units.7 3 4
  6. Question the electronic lock. Ask whether codes are stored inside the safe, whether the outside keypad has any service interface, who holds any manager, recovery or reset code and how firmware updates reach installed locks, and change the recovery and encryption codes where the lock allows it.35 38 37 22
  7. Compare against the federal lock specification. FF-L-2740B and its Amendment 2 are public even though the locks are sold only to authorized buyers. Their requirements are a useful benchmark: critical parameters stored inside the microcontroller, no externally available firmware interface, GSA control of firmware changes, Style 1’s self-generated integral power and lack of data ports, and 20-hour surreptitious-entry resistance.20 22
  8. For classified storage, check procurement records. Confirm the NSN order through GSA Global Supply, or the Direct Purchase Authority or direct IPS purchase where those apply, and a qualified manufacturer; report equipment that arrives with missing or invalid labels or signs of drilling or welding to GSA.23 16
  9. Inventory black labels. Record each black-label item’s specification and class: the listed cabinets lose approval on 1 October 2028 and the listed vault doors on 1 October 2035.16
  10. Check the alarm design, not the container. For contractor alarms used as supplemental protection for Top Secret or Secret, confirm cognizant security agency approval, coverage of entry points and intruder paths, close-of-business activation and no sensors on GSA-approved containers.33
  11. Audit combination changes. Confirm that changes are made by persons authorized access at the protected level and recorded on entry into service, on departures and after possible unauthorized disclosure, unless other sufficient controls exist.32
  12. Know who opens a locked-out container. Identify in advance the trained, authorized personnel who can neutralize and repair under FED-STD-809E, and check whether a black-label cabinet would lose its approval if opened.28 23

Conclusion

A UL 687 class, a UL 768 group and a GSA approval label each certify something real and narrow. UL 687 records that prepared testers did not achieve entry within the stated minutes on the surfaces the class names. UL 768 records how a mechanical lock resisted being read rather than broken. The GSA classes are graded by surreptitious, covert and forced entry under federal test conditions, and Class 6 has no forced-entry requirement. For Top Secret in a GSA-approved container, 32 CFR 2001.43 then adds a two-hour inspection, an alarm answered within 15 minutes, or security-in-depth with an FF-L-2740 lock; Secret in such a container and Confidential need no supplemental control. Combinations, repair and retirement are controlled at every level. Commercial buyers get the tested product and must supply the rest themselves. Two published studies reported exploitable design flaws in specific electronic safe locks that the researchers describe as certified. DoD told Senator Wyden’s office that manufacturer reset codes are prohibited in locks approved for government use through the surreptitious and covert entry requirements of FF-L-2740B, and that any master override mechanism would likely be a vulnerability. A rating is evidence about one tested design under stated conditions, not a measured delay against a real attacker, and specifications should be written with that limit in mind.

Footnotes

  1. “UL 687, Burglary-Resistant Safes” (Edition 15, published 19 July 2011, reaffirmed 1 July 2025 with no technical changes; scope sections 1.1 to 1.3 and Summary of Topics), UL Standards & Engagement catalogue, accessed 27 November 2026. https://shopulstandards.com/ProductDetail.aspx?UniqueKey=23121 (opens in a new tab) ↩1 ↩2 ↩3 ↩4 ↩5 ↩6 ↩7 ↩8 ↩9 ↩10
  2. “UL 768, Combination Locks” (Edition 8, published 6 January 2006, last revision 22 August 2023; scope sections 1.1 to 1.3; bulletin “Summary of Topics”, 17 October 2007, items 4 and 7; reverse references), UL Standards & Engagement catalogue, accessed 27 November 2026. https://www.shopulstandards.com/ProductDetail.aspx?productId=UL768 (opens in a new tab) ↩1 ↩2 ↩3 ↩4 ↩5 ↩6 ↩7
  3. Federal Specification AA-F-358K, “Filing Cabinet, Legal and Letter Size, Uninsulated, Security”, General Services Administration, 16 February 2023, sections 1.2.1, 3.3.2.1, 3.7, 4.6.11 and 4.6.12 (archived copy from the DoD Lock Program). https://web.archive.org/web/20250531001322/https://exwc.navfac.navy.mil/Portals/88/Documents/EXWC/DoD_Locks/PDFs/AA-F-358K.pdf (opens in a new tab) ↩1 ↩2 ↩3 ↩4 ↩5 ↩6 ↩7 ↩8 ↩9 ↩10 ↩11 ↩12 ↩13
  4. Logan Moore, “Safes 101: Decoding the Underwriters Laboratories Rating System & More”, Jewelers Mutual Group, 17 February 2015. https://www.jewelersmutual.com/clarity-blog/safes-101-decoding-the-underwriters-laboratories-rating-system-more (opens in a new tab) ↩1 ↩2 ↩3 ↩4
  5. “Cracking the Code: A Glimpse into UL’s Burglary Testing of Safes”, UL, 10 September 2019 (archived copy of 23 October 2020). https://web.archive.org/web/20201023062919/https://www.ul.com/news/cracking-code-glimpse-ul%27s-burglary-testing-safes (opens in a new tab) ↩1 ↩2 ↩3 ↩4 ↩5
  6. “Burglary Ratings”, Safe and Vault Store (safe dealer), sections on residential and construction-based ratings, RSC and TL-15, accessed 27 November 2026. https://www.safeandvaultstore.com/pages/burglary-ratings (opens in a new tab) ↩1 ↩2 ↩3 ↩4 ↩5 ↩6 ↩7 ↩8
  7. “Anti-Theft Device Testing and Certification” (UL 1037 residential security containers), UL Solutions, accessed 27 November 2026. https://www.ul.com/services/anti-theft-device-testing-and-certification (opens in a new tab) ↩1 ↩2 ↩3 ↩4 ↩5 ↩6
  8. “Residential Security Container Standard Revised”, UL Solutions, 1 August 2017. https://www.ul.com/news/residential-security-container-standard-revised (opens in a new tab) ↩1 ↩2
  9. Jake Shaw, “Understanding UL and ETL Ratings for Your Home Safe”, Liberty Safe, 17 November 2026. https://www.libertysafe.com/blogs/the-vault/understanding-ul-and-etl-ratings-for-your-home-safe (opens in a new tab) ↩
  10. “Turning Up the Heat: A Sneak Peek into UL’s Fire Testing of Safes”, UL, 1 December 2015. https://www.ul.com/news/turning-heat-sneak-peek-uls-fire-testing-safes (opens in a new tab) ↩1 ↩2 ↩3
  11. MIL-HDBK-1013/8, “Military Handbook: Combination Locks”, Naval Facilities Engineering Command, 1 December 1989, sections 2.1.1 and 2.2.1 (archived copy from the DoD Lock Program). https://web.archive.org/web/20250531003110/https://exwc.navfac.navy.mil/Portals/88/Documents/EXWC/DoD_Locks/PDFs/MIL-HDBK-1013-08.pdf (opens in a new tab) ↩1 ↩2 ↩3 ↩4
  12. “Mechanical Combination Locks for Protection of Arms, Ammunition, and Explosives”, DoD Lock Program, NAVFAC EXWC (archived copy of 11 June 2026). https://web.archive.org/web/20260611160424/https://exwc.navfac.navy.mil/DoD-Lock-Program/Security-Hardware/Combination-Locks/Product-Information/Weapons-Storage-Armory-Vault-Locks/ (opens in a new tab) ↩1 ↩2
  13. “UL 2058, Outline of Investigation for High-Security Electronic Locks”, UL Standards & Engagement catalogue, accessed 27 November 2026. https://www.shopulstandards.com/PurchaseProduct.aspx?UniqueKey=12715 (opens in a new tab) ↩
  14. Plore, “Side-channel attacks on high-security electronic safe locks”, DEF CON 24, 2016 (updated slides: background, S&G 6120, Titan PivotBolt, “Are there better locks?” and disclosure slides). https://media.defcon.org/DEF%20CON%2024/DEF%20CON%2024%20presentations/DEF%20CON%2024%20-%20Plore-Side-Channell-Attacks-High-Security-Locks-UPDATED.pdf (opens in a new tab) ↩1 ↩2 ↩3 ↩4 ↩5
  15. 32 CFR 2001.42, “Standards for security equipment”, paragraph (a), Code of Federal Regulations, 1 July 2025 edition, GovInfo. https://www.govinfo.gov/content/pkg/CFR-2025-title32-vol6/xml/CFR-2025-title32-vol6-sec2001-42.xml (opens in a new tab) ↩
  16. ISOO Notice 2026-06, “Standards for GSA Approved Security Equipment”, Information Security Oversight Office, National Archives, 31 August 2026, paragraphs 2, 5, 7, 8, 9 and 10. https://isoo-overview.blogs.archives.gov/wp-content/uploads/sites/3/2026/08/ISOO-Notice-2026-06-on-Standards-for-GSA-Approved-Equipment_FINAL.pdf (opens in a new tab) ↩1 ↩2 ↩3 ↩4 ↩5 ↩6 ↩7 ↩8 ↩9 ↩10 ↩11 ↩12 ↩13 ↩14 ↩15 ↩16 ↩17
  17. “Federal Specifications and Qualified Products Lists (QPL)”, DoD Lock Program, NAVFAC EXWC (archived copy of 15 July 2026). https://web.archive.org/web/20260715221456/https://exwc.navfac.navy.mil/DoD-Lock-Program/Documents/Federal-Specifications/ (opens in a new tab) ↩1 ↩2
  18. Federal Specification AA-F-363D, “Filing Cabinet, Security, Maps and Plans, General Filing, and Storage”, General Services Administration, 1 June 2001, section 1.2.1 (archived copy from the DoD Lock Program). https://web.archive.org/web/20250531003152/https://exwc.navfac.navy.mil/Portals/88/Documents/EXWC/DoD_Locks/PDFs/AA-F-363D.pdf (opens in a new tab) ↩
  19. Federal Specification AA-D-600D, “Door, Vault, Security”, General Services Administration, 15 May 2000, section 1.2.1 (archived copy from the DoD Lock Program). https://web.archive.org/web/20250531002804/https://exwc.navfac.navy.mil/Portals/88/Documents/EXWC/DoD_Locks/PDFs/AA-D-600D.pdf (opens in a new tab) ↩
  20. Federal Specification FF-L-2740B, “Locks, Combination, Electromechanical”, General Services Administration, 15 June 2011, sections 1.1, 1.2, 3.5.4, 3.7, 4.6.8.3, 4.6.8.4 and 6.3 (base text; archived copy from the DoD Lock Program). https://web.archive.org/web/20260206173452/https://exwc.navfac.navy.mil/Portals/88/Documents/EXWC/DoD_Locks/PDFs/FF-L-2740.pdf (opens in a new tab) ↩1 ↩2 ↩3 ↩4 ↩5 ↩6 ↩7 ↩8 ↩9 ↩10 ↩11 ↩12
  21. “FF-L-2740B and its Locks”, Security Facts Newsletter, Issue 27, page 1, DoD Lock Program, NAVFAC EXWC, undated (archived copy). https://web.archive.org/web/20250531000452/https://exwc.navfac.navy.mil/Portals/88/Documents/EXWC/DoD_Locks/PDFs/SFN_Issue_27.pdf (opens in a new tab) ↩1 ↩2 ↩3
  22. FF-L-2740B Amendment 2, “Amendment to Federal Specification: Locks, Combination, Electromechanical”, General Services Administration, 21 August 2018, paragraphs 3.5.5, 3.5.17 and 3.7.5 (archived copy from the DoD Lock Program). https://web.archive.org/web/20250531003153/https://exwc.navfac.navy.mil/Portals/88/Documents/EXWC/DoD_Locks/PDFs/FF-L-2740B_A2.pdf (opens in a new tab) ↩1 ↩2 ↩3 ↩4 ↩5
  23. “GSA-Approved Security Container and Vault Door Program: Program Information and Purchasing Guide”, U.S. General Services Administration, published June 2026, pages 5 to 8, 13 to 16 and questions 5, 10 and 15. https://www.gsa.gov/system/files/GSA-Approved%20Security%20Container%20and%20Vault%20Door%20Program%20-%20Purchasing%20Guide%20-%20Published%20June%202026%20-%20508C%20%281%29.pdf (opens in a new tab) ↩1 ↩2 ↩3 ↩4 ↩5 ↩6 ↩7 ↩8 ↩9 ↩10 ↩11 ↩12
  24. Federal Specification FF-L-2937, “Combination Lock, Mechanical”, General Services Administration, 31 January 2005, sections 1.1, 1.2 and 4.7.7 (archived copy from the DoD Lock Program). https://web.archive.org/web/20250531000747/https://exwc.navfac.navy.mil/Portals/88/Documents/EXWC/DoD_Locks/PDFs/FF-L-2937.pdf (opens in a new tab) ↩1 ↩2
  25. Federal Specification FF-L-2938, “Locks, Combination, Electromechanical, US Allies”, General Services Administration, 17 August 2022, sections 1.1 and 1.1.1 (archived copy from the DoD Lock Program). https://web.archive.org/web/20250531003152/https://exwc.navfac.navy.mil/Portals/88/Documents/EXWC/DoD_Locks/PDFs/FF-L-2938.pdf (opens in a new tab) ↩
  26. Federal Specification FF-L-2890C, “Lock Extensions (Pedestrian Door Lock Assembly Preassembled, Panic and Auxiliary Deadbolt)”, General Services Administration, 22 February 2019, section 1.1 (archived copy from the DoD Lock Program). https://web.archive.org/web/20250531001235/https://exwc.navfac.navy.mil/Portals/88/Documents/EXWC/DoD_Locks/PDFs/FF-L-2890C.pdf (opens in a new tab) ↩
  27. “GSA Approved Security Containers”, DoD Lock Program, NAVFAC EXWC (archived copy of 10 August 2026). https://web.archive.org/web/20260810020716/https://exwc.navfac.navy.mil/DoD-Lock-Program/Security-Hardware/GSA-Approved-Security-Containers/ (opens in a new tab) ↩1 ↩2 ↩3 ↩4 ↩5 ↩6 ↩7
  28. FED-STD-809E, “Inspection, Maintenance, Neutralization and Repair of GSA Approved Containers, Lock Extensions and Vault Doors”, General Services Administration, 17 February 2023, sections 4.3 to 4.7 and Table 3 notes (archived copy from the DoD Lock Program). https://web.archive.org/web/20250531000746/https://exwc.navfac.navy.mil/Portals/88/Documents/EXWC/DoD_Locks/PDFs/FEDSTD-809E.pdf (opens in a new tab) ↩1 ↩2 ↩3
  29. 32 CFR 2001.40, “General” (safeguarding), paragraph (b), Code of Federal Regulations, 1 July 2025 edition, GovInfo. https://www.govinfo.gov/content/pkg/CFR-2025-title32-vol6/xml/CFR-2025-title32-vol6-sec2001-40.xml (opens in a new tab) ↩1 ↩2
  30. FED-STD-832, “Construction Methods and Materials for Vaults”, General Services Administration, 1 September 2002, sections 1, 4, 5.1, 5.2 and 5.3 (archived copy from the DoD Lock Program). https://web.archive.org/web/20260810010206/https://exwc.navfac.navy.mil/Portals/88/Documents/EXWC/DoD_Locks/PDFs/FEDSTD-832.pdf (opens in a new tab) ↩1 ↩2 ↩3 ↩4 ↩5
  31. 32 CFR 2001.53, “Open storage areas”, Code of Federal Regulations, 1 July 2025 edition, GovInfo. https://www.govinfo.gov/content/pkg/CFR-2025-title32-vol6/xml/CFR-2025-title32-vol6-sec2001-53.xml (opens in a new tab) ↩1 ↩2 ↩3
  32. 32 CFR 2001.43, “Storage”, Code of Federal Regulations, 1 July 2025 edition, GovInfo. https://www.govinfo.gov/content/pkg/CFR-2025-title32-vol6/xml/CFR-2025-title32-vol6-sec2001-43.xml (opens in a new tab) ↩1 ↩2 ↩3 ↩4 ↩5 ↩6 ↩7 ↩8 ↩9 ↩10 ↩11 ↩12 ↩13 ↩14 ↩15
  33. 32 CFR 117.15, “Safeguarding classified information” (National Industrial Security Program Operating Manual), paragraphs (b), (c), (d)(1), (d)(2) and (d)(4) and the paragraph on combinations to locks, Code of Federal Regulations, 1 July 2025 edition, GovInfo. https://www.govinfo.gov/content/pkg/CFR-2025-title32-vol1/xml/CFR-2025-title32-vol1-sec117-15.xml (opens in a new tab) ↩1 ↩2 ↩3 ↩4 ↩5 ↩6 ↩7
  34. 32 CFR 2001.92(s), definition of “Security-in-depth”, Code of Federal Regulations, 1 July 2025 edition, GovInfo. https://www.govinfo.gov/content/pkg/CFR-2025-title32-vol6/xml/CFR-2025-title32-vol6-sec2001-92.xml (opens in a new tab) ↩
  35. Mark Omo and James Rowley, “Cash, Drugs, and Guns: Why Your Safes Aren’t Safe”, DEF CON 33, August 2025, slides 4, 6, 12, 15, 27, 44, 47 to 57, 65 and 68. https://media.defcon.org/DEF%20CON%2033/DEF%20CON%2033%20presentations/Mark%20Omo%20James%20Rowlery%20-%20Cash,%20Drugs,%20and%20Guns%20Why%20Your%20Safes%20Aren't%20Safe.pdf (opens in a new tab) ↩1 ↩2 ↩3 ↩4 ↩5 ↩6
  36. “DEF CON 33 Speakers”: listing for “Cash, Drugs, and Guns: Why Your Safes Aren’t Safe”, DEF CON, 2025. https://defcon.org/html/defcon-33/dc-33-speakers.html (opens in a new tab) ↩
  37. “Liberty Safe, Access Codes, and the FBI: The Facts”, Liberty Safe, accessed 27 November 2026. https://libertysafe.com/pages/access-code-facts (opens in a new tab) ↩1 ↩2
  38. Senator Ron Wyden, letter to Michael C. Casey, Director, National Counterintelligence and Security Center, 13 March 2024, pages 1 and 2, with attached DoD responses to questions 1 to 3. https://www.wyden.senate.gov/download/wyden-letter-to-ncsc-on-lock-backdoors&download=1 (opens in a new tab) ↩1 ↩2 ↩3 ↩4
  39. Tobias, Bluzmanis and Fiddler, “Safes and Containers: Insecurity Design Excellence”, DEF CON 20, 2012 (slides: “Myths about security and product design”, “Standards: the problem”, “Small gun safes”). https://media.defcon.org/DEF%20CON%2020/DEF%20CON%2020%20presentations/DEF%20CON%2020%20-%20Tobias-Bluzmanis-Fiddler-Safes-and-Containers.pdf (opens in a new tab) ↩
  40. “Biometric Gun Safes Recalled Due to Serious Injury Hazard and Risk of Death; Imported by Awesafe”, recall 24-127, U.S. Consumer Product Safety Commission, 22 February 2024. https://www.cpsc.gov/Recalls/2024/Biometric-Gun-Safes-Recalled-Due-to-Serious-Injury-Hazard-and-Risk-of-Death-Imported-by-Awesafe (opens in a new tab) ↩