Research Library · Idea
FED-STD-832
FED-STD-832, Construction Methods and Materials for Vaults, is the U.S. federal standard that sets minimum construction requirements for high-security vaults that store classified information and weapons. The General Services Administration issued the current text on 1 September 2002 and authorized its use by all federal agencies. 1
The standard defines three classes. Class A vaults give the maximum protection against tool and torch attack. Their walls, floor and ceiling are 8-inch (200 mm) reinforced concrete with 5/8-inch reinforcing bar at 6 inches on centre each way, the wall steel is tied into the floor and ceiling, and the concrete must reach a 28-day compressive strength of at least 3,000 psi. Class B vaults give less than maximum protection and must conform to the modular vault specification AA-V-2737; the standard counts a portable modular vault as equivalent to Class B. Class C vaults, also less than maximum, are steel-lined and are meant for places where structural circumstances rule out concrete, with high-strength steel plates continuously welded to load-bearing members. Every class takes a door and frame meeting AA-D-600 for Class 5 vault doors. 1 In Class A and Class C vaults, ducts, pipes and other openings larger than 96 square inches and more than 6 inches across at their narrowest need barriers of 9-gauge expanded metal mesh or welded half-inch steel bars, with solid caulking that would show an attempt at surreptitious entry. 1 The DoD Lock Program publishes the current vault door and modular vault specifications with their amendments and qualified products lists. 4
FED-STD-832 specifies construction; it does not define an attack test. Its weight comes from the classified storage rules. 32 CFR 2001.43 allows Top Secret to be stored in a vault built to the standard, as well as in GSA-approved containers and open storage areas, and exempts Secret held in such a vault from the inspection or alarm controls otherwise required. 2 ISOO Notice 2026-06 states that the supplemental controls the rule requires for Top Secret apply to these vaults as well as to GSA-approved containers. 3 For cleared contractors, 32 CFR 117.15 lists vaults built to Federal Standard 832 among the three approved forms of storage. 5
Source · FED-STD-832, Construction Methods and Materials for Vaults (opens in a new tab) · U.S. General Services Administration, via DoD Lock Program (Internet Archive copy)
References
- FED-STD-832, Construction Methods and Materials for Vaults (opens in a new tab) · U.S. General Services Administration, via DoD Lock Program (Internet Archive copy) · September 1, 2002 · Sections 1, 4 and 5. ↩ ↩ ↩
- 32 CFR 2001.43, Storage (opens in a new tab) · U.S. Government Publishing Office (GovInfo) · July 1, 2025 · Code of Federal Regulations, annual edition revised as of 1 July 2025. ↩
- ISOO Notice 2026-06: Standards for GSA Approved Security Equipment (opens in a new tab) · Information Security Oversight Office, National Archives · August 31, 2026 ↩
- Federal Specifications and Qualified Products Lists (QPL) (opens in a new tab) · DoD Lock Program, NAVFAC EXWC (Internet Archive copy) · Index of current specifications, amendments and qualified products lists; archived 15 July 2026. ↩