Abstract

How do security professionals decide what protection a building needs, and how defensible is the decision? For United States federal civilian facilities the answer is a published standard, the Interagency Security Committee’s Risk Management Process (2024 edition, version 4.0). Five scored factors give a preliminary Facility Security Level from I to IV, which may move one level for documented intangibles; Level V is a separate agency decision. The level sets a provisional planning baseline of countermeasures and the reassessment interval. A risk assessment against a restricted design-basis threat sets the necessary protection, and protection below it must be documented as accepted risk. ASIS standards describe a security risk assessment process for organizations outside the federal rule. The federal scores are ordinal, and the threat input starts from central baseline ratings. GAO found that of more than 32,000 Federal Protective Service recommendations made in fiscal years 2017 to 2023, fewer than 1,800 were recorded as implemented by October 2023 among those with a documented approval date, and the status of more than half was unknown. A facility assessment is best treated as a documented argument whose assumptions and accepted gaps are written down.

The problem a facility standard solves

The locks, guards, cameras, barriers and procedures at a building reflect a judgment about who might attack, how, and what it would cost if they succeeded. For nonmilitary federal facilities in the United States, the federal government has tried to make that judgment formal, uniform and auditable, and has published the method apart from three restricted appendices. That makes it a useful specimen: its strengths and weaknesses can be read and argued about.

A narrower question than “is the building secure?” is more useful: what does a facility security assessment actually measure, and how much weight can the decision it produces bear? The federal answer is a chain of steps set out in the standard.1 Five facility characteristics are scored and summed into a preliminary level, which may be adjusted by one level for documented intangibles, while the highest level is assigned by separate agency judgment. The level points to a baseline set of countermeasures that is used only for planning until a risk assessment is done. The assessment determines the necessary protection. If that cannot be achieved, the decision-makers identify the highest achievable protection, consider whether the remaining risk is acceptable or whether another location is possible, and document any residual gap they accept.2 Each link can be examined separately.

The Interagency Security Committee

From Oklahoma City to CISA

On 19 April 1995 a truck bomb destroyed the Alfred P. Murrah Federal Building in Oklahoma City. The ISC’s own history notes that the building housed 14 federal agencies and a day-care center, and calls the attack “the worst domestic-based terrorist attack against the United States government in our history.”3 Six months later, on 19 October 1995, President Clinton signed Executive Order 12977 creating the Interagency Security Committee. The order made the Administrator of General Services its chair and directed it to “develop and evaluate security standards for Federal facilities, develop a strategy for ensuring compliance with such standards, and oversee the implementation of appropriate security measures in Federal facilities.”4

When the Department of Homeland Security was created, Executive Order 13286 of 28 February 2003 amended EO 12977 to replace the Administrator of General Services with the Secretary of Homeland Security.5 On 27 November 2023, Executive Order 14111 superseded and revoked EO 12977. The new order restates the committee’s duties, requires each agency to designate a senior official “responsible for agency implementation of, and compliance with, this order”, and tells the Secretary to monitor compliance through “compliance benchmarks”, “periodic compliance reporting by all relevant agencies” and “risk-based compliance verification”.6 The 2024 standard records that the ISC is chaired by CISA’s Executive Assistant Director for Infrastructure Security and has 66 member departments and agencies.3

What the standard covers, and whom it binds

The governing document is The Risk Management Process: An Interagency Security Committee Standard, usually called the RMP. Its change history lists version 1.0 in August 2013, 2.0 in November 2016, 3.0 in November 2021 and 4.0 in July 2024; the 2024 edition is the current one, published as a PDF by CISA.37 Before 2013 the ISC had issued separate documents, including Facility Security Level determinations (March 2008), Physical Security Criteria for Federal Facilities (April 2010), the Design-Basis Threat Report (April 2010) and the Facility Security Committee standard (July 2011); the RMP consolidated them.3

The RMP says it applies to federally owned or leased buildings, structures and land “regularly occupied by executive branch federal employees and/or federal contract workers for nonmilitary activities”, and that the responsible authority determines what counts as “regularly occupied”.3 EO 14111’s definition of a federal facility also covers a building or structure a contractor acquires, in whole or in part, “solely for the purpose of executing a nonmilitary Federal mission or function under the direction of an agency”, and excludes “public domain land, including improvements thereon; withdrawn lands; or buildings or facilities outside of the United States.”6 Each agency must comply “except in situations in which” the Director of National Intelligence, or an Intelligence Community official in the DNI’s office designated by the Director, determines that compliance “would jeopardize intelligence sources and methods”.6

The RMP also records extensions and carve-outs. The Department of Energy complies to the extent consistent with its Atomic Energy Act obligations. The RMP cites a 2022 GSA rule, effective 23 September 2022, that amended 41 CFR 102-81.25 to clarify agencies’ responsibility for meeting ISC standards at facilities and grounds “under the jurisdiction, custody, or control of GSA”.38 GSA later removed and reserved all of Part 102-81 in a deregulatory rule effective 16 December 2025, which the Administrator ratified on 14 January 2026.910 The agencies’ obligation to comply with ISC standards rests on EO 14111 section 6(b).6 The 2024 RMP also cites DoD Instruction 2000.12, in the version then in force, as requiring DoD leased space and space in GSA-owned or -operated buildings off DoD property to comply.3

Two scope limits matter for anyone tempted to borrow the method. The RMP “primarily addresses human-made threats” and does not address risks such as earthquakes, fires or storms. Critical infrastructure such as dams, bridges and monuments is outside its focus, although its processes “may still be useful” there.3

The five steps

The 2024 edition describes a “five-step methodology”.3 Its table of contents names the steps:

  1. Determine the Facility Security Level (FSL) and baseline Level of Protection (LOP).
  2. Identify and assess risk.
  3. Develop a risk management strategy.
  4. Implement the risk management strategy.
  5. Measure performance.

The process is meant to cycle. Step five can send an organization back to step two or three if countermeasures are not performing, and a change at the facility can send it back to step one.1 The 2021 edition presented the process as a flowchart of numbered decision points, and that edition added “Measure Performance” as a separate step.11

Responsibility is split among named roles. The security organization, the agency responsible for physical security at the site, performs the FSL analysis and risk assessments. At many federal buildings that is the Federal Protective Service (FPS), which, in GAO’s words, “conducts security assessments and recommends countermeasures”.12 The responsible authority, defined as the Facility Security Committee (FSC), the tenant representative for a single-tenant facility, or a legal authority such as a judge in a courtroom, makes the decisions. The organizational security element, a tenant’s headquarters or regional security component or equivalent, tracks decisions and funding. The owning or leasing authority handles real estate.3 Separating the analyst from the decision-maker makes it possible to see afterwards who advised what and who decided.

Step one: the Facility Security Level

The matrix

The FSL is the first number the process produces. The RMP describes “five equally weighted security evaluation factors with corresponding points of 1,2,3 or 4 allocated for each factor”, plus a sixth element, intangibles.1 The five factor scores are summed, and the point total assigns a preliminary FSL category. The size bands below are those of Table 6; the summary matrix in Table 2 gives the lowest size band as “<10,000 Sq. ft.”, which leaves exactly 10,000 square feet in no band, while Table 6 puts it in the lowest (“Up to 10,000 square feet”). Population has a similar gap: the 1-point band is “Less than 100 people” and the 2-point band starts at 101.1

Factor1 point2 points3 points4 points
Mission criticalityMinimumLowMediumHigh
SymbolismMinimumLowMediumHigh
Facility populationfewer than 100101 to 250251 to 750more than 750, or a federal child-care center
Facility size (sq ft, Table 6)up to 10,00010,001 to 100,000100,001 to 250,000more than 250,000
Threat to tenant agenciesMinimumLowMediumHigh

The sum maps to a preliminary level: 5 to 7 points is Level I, 8 to 12 is Level II, 13 to 17 is Level III and 18 to 20 is Level IV. The security organization and responsible authority then “consider and document intangibles” and may adjust the FSL “by either a one-level increase or a one-level decrease”.1 Level V is not reached by points. The criteria and decision for Level V are “within the purview of the individual agency”, with the guidance that a facility is a candidate if it receives a “high” score for mission criticality or symbolism and “is a one-of-a-kind facility (or nearly so)”.1

What each factor asks

Each factor comes with a table of criteria and examples.

Mission criticality rates the missions of the federal tenants in the building, not of the agencies as a whole, and a multi-tenant building takes the highest-rated tenant. High (4 points) includes seats of government, facilities that house “essential communications, workstations, electronic equipment, or hardcopy documentation necessary for defense or intelligence activities”, continuity-of-government facilities, the Mint and Federal Reserve buildings, and Department of Energy research reactors. Minimum (1 point) is “Administrative, direct service, or regulatory activities at a local level”, with an agricultural county extension office as the example.1

Symbolism is “based on both its attractiveness as a target and the consequences of an event.” High examples include the White House, executive department headquarters and federal courthouses. The Oklahoma City Federal Building is listed as a Medium example of “Well-known, regional U.S. Government facilities”. Minimum is a facility with “No external features or public contact readily identifying it as a U.S. Government facility”.1 One point may be added where the land associated with the facility “significantly contributes to the target attractiveness”, provided the rationale is documented and the score does not exceed four points.1

Facility population counts federal occupants plus the average number of visitors present, excluding transient peaks such as an occasional conference. The standard explains: “From a consequence perspective, the potential for mass casualties should be a major consideration.” Every federal child-care center, or facility with one, receives the High value regardless of headcount.1 A point may be added, with documented rationale and within the four-point cap, where a non-federal population adds substantially to target attractiveness.1

Facility size is federally occupied square footage. The text notes that large buildings attract media coverage but “require a more substantial attack to create catastrophic damage”, and that “from a consequence perspective” replacement cost is a major consideration. The same documented, capped one-point addition is allowed where the total size of a mixed-tenant building contributes to target attractiveness.1

Threat to tenant agencies is the factor that looks at adversaries directly. It weighs whether public contact is adversarial, whether the mission is controversial, past and current credible threats, threats to co-tenants, and local crime statistics. In a multi-tenant facility the factor takes “the highest value of any one federal tenant.” Some criteria count incidents: the High value includes a significant history of violence with “More than ten incidents per year requiring law enforcement/security response/investigation for unruly or threatening persons”, and Medium includes five to ten such incidents onsite. For crime statistics the standard gives guidelines the security organization “should use”, such as data for the prior 12 months when available and a radius of up to one mile, with broader areas for smaller cities and rural locations.1

Intangibles allow a one-level change for considerations such as a short occupancy (down) or cascading effects on dependent infrastructure (up). Organizations “will not use intangible factors to raise the FSL in response to a particular threat”, because specific threats belong in the risk assessment, and the adjustment may not be used to reduce the baseline LOP.1

A worked example

The facts in this example are hypothetical. Consider a district office of a federal benefits agency on two floors of a leased commercial building in a mid-sized city.

  • Mission criticality. The office’s work is district-wide service delivery, matching the Low criterion “District or State-wide service or regulatory operations”: 2 points.1
  • Symbolism. The office has no federal seal on the façade but is recognizable from its public counter, matching the Low criterion “Readily identified as a U.S. Government facility based on the nature of public contact or other operations (even without external features)”: 2 points.1
  • Population. 180 staff and contractors, plus an average of 60 visitors present: 240 people, 2 points.1
  • Size. 45,000 square feet: 2 points.1
  • Threat to tenant agencies. Assume the agency’s benefit decisions make contact “occasionally adversarial based on the nature of business conducted at the facility”, a Medium criterion: 3 points.1

The sum is 11, a preliminary Level II. With no intangibles the final FSL is II, the baseline LOP is Low, and the security organization must reassess the site every five years.1

Small changes test the result. If average visitors rise to 80, population becomes 260 and scores 3; the sum is 12 and the facility stays at Level II. If the building opens a federal child-care center, population takes the High value whatever the headcount; the sum becomes 13, the facility moves to Level III, its baseline LOP to Medium, and its reassessment cycle from five years to three.1

A second hypothetical shows a different property. Suppose a small, unmarked annex of 8,000 square feet, staffed by 40 people, houses documentation and equipment “necessary for defense or intelligence activities”, which meets a High mission criticality criterion (4 points). Suppose also that it has no external features or public contact identifying it as federal, little or no public contact, no history of demonstrations or violence, and a location in a very low-crime area, which puts symbolism and threat at Minimum, while its size and population are in the lowest bands. Every other factor scores 1, the sum is 8, and the preliminary level is II, the same as the benefits office. The standard’s Level V guidance describes a related case, a laboratory whose low scores for symbolism, size and population understate a mission whose criticality “would far outweigh” them; that guidance concerns the agency’s separate Level V determination.1 For the annex, the intangible adjustment would allow a move to Level III, and the agency could consider Level V if the facility were one of a kind. The point concerns the scoring rule: an additive score lets a low position on several factors offset a high position on one, and maps very different facilities to the same preliminary level.

The shape of the score

The following counts are the author’s enumeration of the Table 2 rule, with every profile counted equally. Every possible assignment of 1 to 4 points across the five factors gives 4⁵ = 1,024 profiles. Of these, 21 sum to Level I (5 to 7 points), 491 to Level II, 491 to Level III and 21 to Level IV under the Table 2 bands.1 So 95.9 percent of equally counted profiles fall in Levels II or III, and the extreme levels require nearly every factor to be at its extreme. With mission criticality fixed at 4, 66 of the 256 combinations of the other four factors still produce Level II. These counts treat every profile as equally likely. They describe the scoring rule and say nothing about how real facilities are distributed or how often their levels change.

The RMP itself comments on this property. It says that “the use of multiple factors in making the FSL determination somewhat dilutes the effect of any one factor and all but prevents a slight change from causing a change in security level.”1 Its illustration, “an increase from 150 to 151 employees”, would not change the population score if total population, occupants and visitors together, moved from 150 to 151, since 101 to 250 is a single band. The band edges are conventions, and the RMP does not explain how they or the equal weights were calibrated.

Who decides

The security organization performs the FSL analysis, but the final determination “rests with the tenant(s)”, acting through the FSC in multi-tenant buildings, in consultation with the security organization and the owning or leasing authority. If they disagree, an ISC regional advisor may facilitate, and unresolved disputes go to the agencies’ senior officials. All parties must “document, sign, and retain” the result.1 The same tenants “must devise a risk management strategy and, if possible, fund the appropriate security countermeasures”, so the party setting the level is also the party asked to pay for what it implies.1

From level to protection

Baseline Level of Protection

Each FSL maps onto a baseline LOP: Level I to Minimum, II to Low, III to Medium, IV to High and V to Very High.1 An LOP is “the degree of security provided by a particular countermeasure or set of countermeasures”, and the countermeasures for each LOP are listed in the security criteria tables of Appendix B.1

The 2024 edition narrows what the baseline is for. It states that the baseline LOP “is only applicable until the security organization completes the risk assessment (i.e., new lease solicitation or new construction)”, and that once an assessment is complete “the baseline LOP is no longer applicable and is replaced by the necessary LOP.”113 The 2021 edition had allowed “the application of the baseline LOP applicable to the facility’s FSL” as one of two outcomes, the other being a customized LOP.11 This is what the 2024 summary of changes means by “Limits use of the baseline Level of Protection (LOP)”.3 The baseline is now a provisional planning package for buildings not yet assessed. The FSL itself “remains applicable after the risk assessment”, where it continues to set the reassessment interval.13 There is also a floor: the LOP implemented “may never be less than Level I-Minimum found in Appendix B: Countermeasures (FOUO), regardless of site conditions”.1

The restricted appendices

The parts of the RMP that make it operational are not public. Appendix A, the Design-Basis Threat Report, Appendix B, Countermeasures, and Appendix C, child-care center LOP template guidance, are marked For Official Use Only.3 What can be said about them comes from the public text:

  • Appendix A “creates a profile of the adversary’s type, composition, and capabilities”, is described as “an estimate of the threat federal facilities face across a range of Undesirable Events (UEs)”, and contains “baseline threat ratings”.313
  • Appendix B “establishes security countermeasures that correspond to levels of protection”, and its tables cross-reference undesirable events with security measures.313
  • Appendix C gives guidance for child-care centers “based on their relationship to federal facilities including campus environments”.3

The 2024 PDF tells users to request access by email to an ISC address. CISA’s standards page lists the appendices as 2023 editions and gives a different route, a request to CISA’s TRIPwire contact for “users with a need-to-know”.14 A GAO review in 2017 reported that the ISC standard at that time identified 33 undesirable events related to physical security, arson and vandalism among them.15 The current list and the countermeasure tables are not public.

Step two: assessing risk

The definition

The RMP defines risk as “a measure of potential harm from an undesirable event that encompasses threat, vulnerability, and consequence”, and the level of risk as “the combined measure of the threat, vulnerability, and consequence posed to a facility from a specified undesirable event.”16 Threat is “the intention and capability of an adversary to initiate an undesirable event.” Consequence is “the level, duration, and nature of the loss”, commonly measured as human, economic, mission and psychological harm.13 In the published PDF the sentence defining vulnerability in section 8.2.1 breaks off mid-clause, but the glossary supplies an annotation: “When calculating the risk of an intentional hazard, the common measure of vulnerability is the likelihood of a successful attack if attempted.”16

No mandated method

The standard does not prescribe how to combine the three terms. It says that “a variety of mathematical models are available to calculate risk” and that “The ISC Risk Management Process does not mandate the use of a specific risk assessment methodology.” Any methodology must meet three principles.13

  • Credible: it must assess threat, vulnerability and consequence for specific undesirable events.
  • Reproducible: it must “produce similar or identical results when applied by various security professionals”.
  • Defensible: it must justify any deviation from the baseline threat ratings in Appendix A and correlate directly with the levels of protection in Appendix B.

At a minimum, “the risk assessment must consider all undesirable events in the DBT.”13 Organizations “should seek ISC certification” for training courses, data tools or applications used in an ISC-compliant assessment, and security organizations must ensure their assessors have completed ISC-certified training.3 The standard does not say how reproducibility is to be demonstrated.

Necessary and existing protection

For each undesirable event, the assessed risk determines the necessary LOP from the Appendix B tables. The RMP illustrates the logic with two mismatches: a Medium baseline where “the assessed risk of theft is very high”, leaving unmitigated risk, and a Medium baseline where “the assessed risk of robbery is minimum”, spending more than necessary.13 The security organization then determines the existing LOP through site surveys, interviews, reviews of procedures, “red team” testing and tabletop exercises, and identifies the gap. For new construction, planners “may have to assume complete vulnerability.”13

The output is a written report and briefing to the responsible authority, followed no later than 45 days later by a final report that gives a scope of work and cost estimate for each countermeasure, operating procedures, and an explanation of how each countermeasure meets the necessary LOP.13 Once the security organization presents a credible, documented assessment and the responsible authority accepts it, the security organization “has met its obligation in providing its best professional advice”, though it remains accountable for the assessment’s accuracy and completeness.13 The 2021 edition makes the same point in slightly different wording.11

Assessments recur every five years for Levels I and II and every three years for Levels III to V, and each review revisits the FSL. Facilities not regularly occupied by federal employees, such as antenna towers or freestanding restrooms, “do not require recurring risk assessments”.1 The intervals are unchanged from 2021.11

Steps three and four: strategy, implementation and accepted risk

The decision sequence

The responsible authority must give the security organization a written response within 90 days of receiving the final assessment report, a period that “includes all FSC deliberations and coordination with organizational headquarters; there is no extension.” The response must contain the decisions made on the identified countermeasures, which may include full implementation, a lower LOP, risk acceptance, or disagreement with a particular recommendation.13 The 2021 edition had no equivalent 90-day requirement.11

Step three works through a sequence of questions: is the necessary LOP achievable, and is it cost-effective? If not, what is the highest achievable LOP? Can it be implemented immediately, or are interim measures needed? The RMP distinguishes “cost-effective”, judged by “the investment in the countermeasure versus the value of the asset or the expected risk level mitigated”, from “cost-prohibitive”, a cost that exceeds available funding, and it “does not mandate the use of a specific cost-analysis methodology.”2 Finding the highest achievable LOP means stepping down one level at a time until a level is achievable. The standard’s example is an air intake: if relocating ground-level intakes to the roof is impossible, the next lower LOP calls for monitoring them with video surveillance and guard patrols.2 If the remaining risk at the highest achievable LOP is not acceptable, the standard directs the parties to consider an alternate location where the necessary LOP is achievable, weighing the delineated area, mission need, market conditions, timeframe and budget.2

In a multi-tenant building the decision is a vote. Each federal tenant has one vote, weighted by the rentable square footage of its assigned space as a share of the building; the FSC may leave joint-use and vacant space out of the calculation. A valid vote needs a quorum of 50 percent of tenant organizations representing at least 51 percent of the space, and a measure passes with more than 50 percent of weighted votes. Abstentions count as “no” votes “due to the potential outcome of risk acceptance if a security measure fails to pass.” If quorum is not met, the result is minuted and the chair may reschedule the vote or submit the matter to second-level review.17 The ballot options range from adopting the necessary LOP in full to “Accept all identified risks without employing any countermeasures.”17 A separate decision process escalates unresolved FSC disputes to second-level review by the organizational security element and third-level review by the senior official.317

Risk acceptance

Risk acceptance is defined as “the explicit or implicit decision not to take an action that would affect all or part of a particular risk.”2 The procedures are written to turn implicit acceptance into documented acceptance:

  • “implementing a lower LOP than the necessary LOP results in risk acceptance.”
  • When an agency does not approve funds, “the decision then results in risk acceptance”, and the headquarters security element must document the denial.
  • The documentation “must clearly state the reason why the necessary LOP is unattainable” and record alternatives considered and future opportunities. The template in Appendix F lists rationales such as physical site limitations, historic integrity, funding priorities, short-term occupancy or a lease ending, and has signature lines for the security organization and responsible authority.
  • The facility-approved strategy involving risk acceptance goes to the headquarters security office of every tenant “for awareness”.217

Disagreement is different from acceptance. If the responsible authority disagrees with an identified countermeasure, for example additional guards that Appendix B does not require, it notes this in its 90-day response.13

The 2024 edition adds an organizational layer. The organizational security element must “Establish and annually review a risk register (i.e., risk acceptance list)” and track countermeasures not implemented and why, and the senior official must maintain “a centralized list of the organization’s risk acceptance for each facility”.3 Reporting to headquarters is required; approval by headquarters is not. The standard says organizations “should consider” approval policies based on their risk tolerance, and gives as an example headquarters approval where a necessary LOP of “very high” or “high” is not achievable, or where the achievable LOP is two or more levels below the necessary one.2 A new section on liability states that “Federal employees acting within the scope of their duties are protected from personal tort liability” under the Westfall Act and advises consulting agency counsel.2 The statute itself makes the remedy against the United States exclusive for damages claims arising from an employee’s negligent or wrongful act within the scope of employment, and excludes actions for violations of the Constitution or of a statute that authorizes suit against the individual.18 None of these risk register, approval-example or liability provisions appears in the 2021 text.11

Step five and compliance

The fifth step asks whether countermeasures work. The security organization documents countermeasure testing, and agencies must run a performance measurement program linked to their goals. The standard’s field-level example is a goal of 99 percent effectiveness in countermeasure tests, and it points to NIST SP 800-55 Revision 1 as a template for measures.19 NIST withdrew Revision 1 on 4 December 2024 and replaced it with SP 800-55 Volumes 1 and 2.20

Compliance reporting predates the 2024 edition. The 2021 standard described the ISC Compliance System, a web application through which agencies “must report information” annually against the ISC’s benchmarks.11 EO 14111 made benchmarks, periodic reporting and risk-based verification an explicit duty of the Secretary.6 The 2024 RMP restates those three elements, requires senior officials to “Ensure compliance reporting on an annual basis and participate in compliance verification”, and says FSC minutes and risk acceptance documentation are “inspectable items” in that process.31917

On training, the 2021 edition required FSC members to complete an ISC course and recommended retaking it when the standard changed significantly.11 The 2024 edition requires federal employees and contractors who participate in the process to complete training within 90 days of assignment, and requires FSC members and those advising on single-tenant decisions to retrain at least every five years, with a recommended three-year cycle for Levels III to V.3

What the record shows

GAO has examined the federal program several times. Its findings concern both how assessments are done and what happens after them.

In 2012 GAO examined FPS’s Modified Infrastructure Survey Tool, which FPS planned to use to assess federal facilities, and reported: “Most notably, MIST does not estimate the consequences of an undesirable event occurring at a facility.” Three of the four risk assessment experts GAO consulted “generally agreed” that a tool that does not estimate consequences “does not allow an agency to fully assess risks.” GAO’s later recommendation updates record that FPS supplemented MIST with an overall consequence score and, by 2017, combined MIST with threat and consequence information from other sources.21

In 2017 GAO reviewed the facility assessment methods of four agencies: Customs and Border Protection, the Federal Aviation Administration, the Agricultural Research Service and the Forest Service. “None of the four agencies GAO reviewed used security assessment methodologies that fully aligned” with the RMP. CBP and FAA “assessed vulnerabilities but not threats and consequences.” The Agricultural Research Service and the Forest Service assessed all three “but did not use these factors to measure risk.” All four considered “many, but not all” of the 33 undesirable events. Three of the four had not met the ISC’s three-year reassessment requirement, and three lacked data or systems to monitor assessment schedules or the status of countermeasures. These findings describe the methods GAO evaluated; GAO also reported that the Agricultural Research Service and Forest Service had moved to a methodology that measures risk, and that CBP and FAA had updated their methodologies, though their policies still did not require full alignment.15

In May 2023 GAO reported that ISC oversight relied on agencies’ self-reported questionnaire answers and “does not verify” that agencies had implemented FPS-recommended countermeasures or “documented the acceptance of risk for those countermeasures they do not implement”.12 GAO’s November 2023 testimony gave figures from FPS data. Between fiscal years 2017 and 2023, FPS “made over 32,000 recommendations at over 5,000 federal facilities.” Facility security committees did not respond to more than half and approved 29 percent. GAO found that “of the recommendations where FPS documented a date of approval in its system, agencies implemented 22 percent—or fewer than 1,800—recommendations” as of October 2023. GAO concluded that until the ISC improved oversight, “the implementation status of more than 50 percent of FPS’s recommended countermeasures will remain unknown”.22 In GAO’s discussion groups, some participants said the ISC’s then 45-day requirement to approve or reject a recommendation was not a reasonable timeframe, and cost and feasibility affected decisions.22

GAO’s product page for the May 2023 report records both recommendations as closed and implemented. According to its notes, the ISC updated its compliance and verification procedures in November 2023 to check risk acceptance documentation where countermeasures were not implemented; completed a pilot in May 2024, which found “that facilities are largely not compliant in documenting risk when not implementing the necessary countermeasures”; and in January 2025 showed GAO that it had added questions on countermeasure implementation to its annual questionnaire.12 These notes confirm changes to oversight. They do not give a new implementation rate across the federal inventory.

The figures cover FPS recommendations only, and an unknown status is not the same as inaction. For more than half of this cohort of recommendations, the outcome after the assessment is unknown. The ISC pilot finding applies to the facilities it selected. The 2024 edition’s risk register, its 90-day written response and its compliance verification provisions address the kinds of gap GAO described.313

Outside the federal rule: ASIS standards

Facilities outside EO 14111’s definition, including most private buildings, have no executive order prescribing a method. The nearest equivalents are standards from ASIS International, the security professionals’ association; ASIS and RIMS, the risk management society, are both ANSI-accredited standards developers.23 The full texts are sold. The descriptions below come from public announcements and store listings and say nothing about clause content.

ANSI/ASIS/RIMS RA.1-2015, Risk Assessment. Announced on 21 October 2015, it was described at release as addressing how to build a risk assessment program, understand the context for assessments, conduct an assessment and use the outcomes in decisions. The announcement said it complements ISO 31000 and ISO 31010:2009 by giving a blueprint for the assessment process, and a RIMS director said the authors included guidance on types of risk assessment, biases and assessor competence.23 ANSI’s store describes it as covering principles, program management, individual assessments, assessor competence and biases, with seven annexes.24

The ASIS Security Risk Assessment Standard. ASIS announced on 16 April 2024 the release of a revised, ANSI-approved Security Risk Assessment Standard, which its store lists as ASIS SRA-2024.25 The announcement lists sections on scope and principles, establishing the assessment’s context, preparing and conducting assessment activities, and post-assessment risk treatment and monitoring, and says the conducting section provides “methodologies for both qualitative and quantitative analysis.”26 ASIS’s standards page says it “replaces the ANSI/ASIS/RIMS RA.1-2015 Standard and the ASIS GSRA 2003 Guideline”, so RA.1-2015 is superseded.27 The ANSI approval date is not given on these pages.

ASIS PAP-2021, Physical Asset Protection. ANSI’s store describes it as using “a management systems approach” to guide “the design, implementation, monitoring, evaluation, and maintenance of a physical asset protection (PAP) program”, including “the identification, application, and management of physical protection systems (PPS)”. It revises ANSI/ASIS PAP.1-2012.28

On the public descriptions alone, the contrast is limited. The ISC publishes a scored facility level, a reassessment schedule and a rule that maps assessed risk to protection levels, while leaving the assessment methodology to agencies within its three principles.113 The ASIS announcements describe a process for organizations to establish context, identify, analyze and evaluate risk, and treat it. Whether the ASIS texts contain scoring rules cannot be determined from those descriptions, and none of the sources cited here compares the outcomes of the two approaches.

Prescriptive rules: classified storage

Some protection requirements are fixed by rule. For classified national security information, 32 CFR 2001.43 sets minimum storage requirements. Top Secret must be stored in a GSA-approved container, a vault built to Federal Standard 832, or a qualifying open storage area. A container then needs one supplemental control: inspection “every two hours by an employee cleared at least to the Secret level”; an intrusion detection system “with the personnel responding to the alarm arriving within 15 minutes of the alarm annunciation”; or security-in-depth coverage of the area together with a lock meeting Federal Specification FF-L-2740. For open storage with security-in-depth, responders must arrive within 15 minutes of alarm annunciation, and without it “within five minutes”.29

Under section 2001.43(b)(2), Secret material is stored in the same manner as Top Secret, subject to Secret-specific provisions. An earlier option to use non-GSA-approved containers applied only “until October 1, 2012”. Security-in-depth is required for open storage areas, and except for GSA-approved containers and FED STD 832 vaults, one supplemental control is required: inspection “every four hours by an employee cleared at least to the Secret level” or an intrusion detection system with responders arriving within 30 minutes of alarm annunciation.29

Two features stand out. The controls are stated partly in time, as inspection intervals and responder arrival times. And the prescriptive regime still rests on a judgment. Security-in-depth is defined as “a determination by the agency head that a facility’s security program consists of layered and complementary security controls sufficient to deter and detect unauthorized entry and movement within the facility.”30

The performance tradition: timely detection

A different line of practice, developed at Sandia National Laboratories for nuclear safeguards, evaluates a protection system by whether a response force can interrupt a defined adversary in time. Mary Lynn Garcia, a Principal Staff Member at Sandia,31 wrote the textbook Design and Evaluation of Physical Protection Systems, whose second edition Elsevier published in September 2007.32 The method is described here from Sandia’s own reports.

A 1978 Sandia report for the Nuclear Regulatory Commission describes EASI, the Estimate of Adversary Sequence Interruption, as consisting of “a probabilistic analysis of the interactions of basic security functions such as detection, assessment, communications, delay, and response time to obtain an estimate of the probability of interrupting an adversary sequence.”33 In its mathematical appendix, the probability of alarm at a sensor is the probability of detection times the probability of communication, P(A) = P(D)P(C). Interruption requires that the adversary’s remaining task time exceed the response force time. The model assumes these times are independent and normally distributed, with task times along the path treated as independent, and computes the probability of interruption cumulatively, sensor by sensor.33 The report recommends varying inputs one at a time to see which matters most, and warns that “the user has the responsibility to assure that the input data properly reflects conditions of the actual security system.”33

A 2007 Sandia training chapter gives a simplified critical-point form. The probability of interruption is “the cumulative probability of detection along the path up to and including the Critical Detection Point”, which is “the last PPS detection component along that path for which the response force time is less than the remaining adversary task completion time.” Interruption is only part of effectiveness. The probability of neutralization is the probability, given interruption, that the response force gains control of the adversary, and system effectiveness on a path is the product of the two. “The overall PPS effectiveness is conservatively defined as the lowest PE for all adversary paths.”34 Adversary sequence diagrams model the facility as concentric layers so that paths to the target can be enumerated.34

The outputs of this approach are probabilities built from quantities that can be tested: detection rates, delay times, response times. It looks for the weakest path. Its results apply to the modeled adversary and paths and do not give a facility-wide likelihood of attack. They depend on a design-basis threat, on the model’s assumptions about timing distributions, and on inputs that the 1978 report warns must represent the actual system. The Sandia sources describe it in the nuclear safeguards setting.3334

What a facility assessment can and cannot measure

Ordinal numbers treated as quantities

The FSL adds five ratings. A rating of 4 for population means more than 750 people; a rating of 1 means fewer than 100. A rating of 4 for size means more than 250,000 square feet; 1 means up to 10,000. The intervals are neither equal nor comparable across factors, yet the sum treats a one-point step in symbolism as interchangeable with a one-point step in population. Equal weighting is a stated choice, and the RMP does not explain how the weights or band edges were derived.1 The combinatorics above show what follows: the sum places most possible profiles in Levels II and III, and it can give a sensitive annex and a benefits office the same preliminary level.

There is a reasonable case for this design. The FSL’s job is limited: to pick a provisional countermeasure package and an assessment interval before a full assessment exists. A coarse, transparent rule suits that kind of triage, and once the five ratings are assigned the arithmetic is fully repeatable. The ratings themselves involve judgment, and no source cited here reports how often different assessors assign the same ones. The difficulty arises when the level is read as a measure of risk, as the heading “Estimated Level of Risk” in the FSL-to-LOP table invites.1

The risk assessment step raises a different question. The RMP permits any methodology that meets its three principles, so the relevant critique depends on the tool. Where a tool maps categorical ratings of likelihood and severity to risk levels, it is a risk matrix of the kind Louis Anthony Cox analyzed. Cox’s 2008 analysis of frequency-severity risk matrices found that typical matrices can unambiguously compare only a small fraction of randomly chosen pairs of hazards (less than 10 percent in his examples), can give identical ratings to very different risks, can rank smaller risks above larger ones, and, when frequency and severity are negatively correlated, can do worse than random. He also found that their categories are not a sound basis for allocating countermeasure resources, and that different users can rate the same risks oppositely.35 His results concern matrices of that form, not the FSL rule or continuous models whose results are later reported in bands, but where they apply they bear on the RMP’s requirement that assessments be reproducible.

Threat estimates for terrorism

For crime, the FSL uses local statistics and incident counts. For terrorism the threat term is harder. The National Research Council’s 2010 review of DHS risk analysis found the general framework of Risk = f(T,V,C) “sound”, while “the operationalization of that framework is in many cases seriously deficient.” It said that “defining the threat and estimating probabilities are inherently challenging”, that in the terrorism domain, where the components are often functionally interdependent, the simple product “does not apply and should not be used”, and, contrasting terrorism models with natural-hazard models it called “near the state of the art”, that “only low confidence should be placed in most of the risk analyses conducted by DHS” until deficiencies were improved.36 That review assessed DHS risk models as they stood in 2010; it is not a finding about facility tools in use today, but the difficulty it describes applies to any facility-level estimate of terrorism likelihood.

Cox’s companion paper on the T × V × C product lists further limitations: it does not adjust for correlations among its components, risks estimated this way are not additive, the scores cannot be used to allocate defensive resources optimally, and the inputs are intrinsically subjective. He argues that assessing probabilities for an intelligent adversary’s actions without modeling how that adversary adapts to defences can produce ambiguous or mistaken estimates.37

The design-basis threat as a standardized estimate

The RMP calls the DBT “an estimate of the threat federal facilities face”.3 It also serves a design purpose: it fixes a common description of the adversary and baseline threat ratings that every assessment must start from, and assessors must justify deviations.13 The standard says the DBT report “fills the void of threat information available to security professionals (especially in smaller agencies without access to current intelligence)”.13 Standardizing the starting point in this way supports consistency across agencies. How far individual assessments depart from the baseline ratings on site-specific evidence is not reported in the public sources.

The Nuclear Regulatory Commission uses the term in a related way. Its regulation lists design basis threats that “shall be used to design safeguards systems to protect against acts of radiological sabotage and to prevent the theft or diversion of special nuclear material”, describing for radiological sabotage an adversary force that includes “[w]ell-trained (including military training and skills) and dedicated individuals, willing to kill or be killed”, with knowledgeable insider assistance.38 There, the DBT is explicitly a design requirement. Reading the ISC’s DBT partly in the same light, as a stated basis for design as well as an estimate, helps when explaining to decision-makers what an assessment’s threat ratings rest on. The library’s article Who is the attacker? discusses how threat models built for one organization differ.

The weight of consequence in the FSL

On a reading of the standard’s own explanations, four of the five FSL factors are framed mainly as target attractiveness or consequence: symbolism (“attractiveness as a target and the consequences of an event”), population (“from a consequence perspective”), size (replacement cost “from a consequence perspective”) and mission criticality (disruption of important missions is “equally attractive to adversaries”).1 One factor addresses threat, largely through crime and hostile public contact. The FSL is therefore mostly a consequence-and-attractiveness score.

For a provisional level that may be reasonable, and the assessment then replaces the baseline LOP with the necessary LOP.13 But the FSL remains in force after the assessment and continues to set how often each site is reassessed, so, on this reading, the frequency of scrutiny is driven mainly by consequence proxies.113 GAO’s 2012 MIST finding shows the opposite problem: without consequence estimates, a tool gives an incomplete assessment and limits comparison of risk across facilities.21

For FPS recommendations made in fiscal years 2017 to 2023, FPS records as of October 2023 showed fewer than 1,800 implemented among those with a documented approval date, and GAO said the status of more than half would remain unknown without better oversight.22 The RMP’s answer is documentation: a protection level below the necessary LOP must be recorded as accepted risk. GAO’s 2023 finding was that the ISC did not verify those records, and the ISC’s 2024 pilot found the facilities it selected “largely not compliant” in documenting risk.12

Who accepts the risk

The responsible authority decides and the security organization advises.13 In a multi-tenant building that authority is a committee voting by floor area, so, where a valid quorum is present, a tenant whose assigned space gives it a majority of the weighted vote can carry or block a countermeasure that mainly protects a smaller, higher-risk co-tenant.17 The standard’s guidance on co-location recognizes the problem: “A tenant requiring a higher level of security should not move into a facility with a low security level”, because either the higher-risk tenant accepts less security or the others pay for more than they need.1 Reporting accepted risk to headquarters is required; headquarters approval of large accepted gaps is offered as an example policy.2

How it compares with quantitative approaches

The library’s article What is it worth protecting? covers annualized loss expectancy, FAIR and their limits. The ISC method sits between those approaches and Sandia-style performance analysis. It asks for cost-effectiveness judgments but mandates no cost method, and it expresses required protection in five ordinal levels, so a countermeasure’s cost and the risk reduction it buys are not stated in common units.2 Separately, step five requires countermeasure testing and performance measures, which can produce measured results such as test pass rates.19 What an LOP category does not state by itself is how much the probability of a successful attack has changed; the Sandia approach expresses that for a specified adversary as probabilities of interruption and neutralization on the weakest path.34

What the method does well

Several features of the RMP may help anyone reviewing a decision afterwards. It separates the analyst from the decision-maker. It requires every undesirable event in a defined catalogue to be considered, which makes omissions visible. It treats funding denials and any implemented level below the necessary LOP as risk acceptance that must be documented, with an absolute floor of Level I-Minimum. It ties reassessment frequency to the facility level. Documenting a decision is not the same as showing that two assessors would reach it, and GAO’s evidence, from selected agencies and from FPS data, shows that the requirements have not always been met.1321522

For anyone who runs or commissions a facility assessment

  1. Record a decision on every recommendation, in writing and on time. (RMP requirement.) Federal responsible authorities must respond within 90 days of the final report. A disagreement that a measure is necessary is noted as such; an implemented level below the necessary LOP, or a funding denial, is documented as accepted risk with its reason; and no facility may fall below Level I-Minimum.1323
  1. Keep the risk register current. (RMP requirement.) Track identified countermeasures that were not implemented and why, and send accepted risk to each tenant’s headquarters. GAO found that the ISC did not verify this documentation, and its 2024 pilot found selected facilities largely not compliant.3212
  1. Make the methodology assess threat, vulnerability and consequence for every undesirable event, and show how they are combined. (RMP requirement.) GAO found agencies that assessed vulnerability alone, did not combine the three, or used a tool that did not estimate consequence.131521
  1. Test countermeasures and record the results. (RMP requirement.) Step five requires testing and performance measures; an untested countermeasure is an assumption carried forward.19
  1. Record the evidence behind every FSL factor and which single change would move the level. (Practice.) A federal child-care center, a new tenant or a change in incident history can shift the level and the reassessment cycle.1
  1. Report threat, vulnerability and consequence separately for each event, with their uncertainty. (Practice, drawn from the critiques cited.) Do not present multiplied or summed ordinal ratings as a risk quantity or allocate money from matrix categories alone.353736
  1. Check reproducibility where the stakes justify it. (Practice proposed here.) Have a second assessor assess the same undesirable events independently and compare the assessed risk, the recommended LOP for each event and the stated uncertainty. A repeat FSL score checks only the preliminary classification.13
  1. State the threat basis. (RMP requirement for departures; practice otherwise.) Write down which adversary the countermeasures are meant to defeat, and record and justify any departure from the baseline threat ratings.13
  1. For high-value targets, examine timing. (Practice, from the Sandia tradition.) Ask for the adversary’s task time along the worst path and the response force time. In the 2007 Sandia chapter’s simplified model, detection counts toward interruption only up to the critical detection point, the last point where response time is still less than the adversary’s remaining task time; effectiveness also depends on neutralization.34
  1. Escalate large accepted gaps. (RMP example policy.) Consider headquarters approval where a high or very high necessary LOP is unachievable or the achievable LOP is two or more levels short.2

Conclusion

For nonmilitary federal facilities, protection is decided by a documented sequence: five ordinal factor scores summed into a preliminary Facility Security Level, an optional one-level adjustment, a separate agency judgment for Level V, a provisional baseline package for planning, a risk assessment against a restricted design-basis threat that sets the necessary protection, and a written record of any implemented shortfall the responsible authority accepts. The 2024 edition of the ISC Risk Management Process confines the baseline to unassessed buildings and adds a 90-day written response, risk registers, recurring training and compliance verification tied to EO 14111. Its scores remain ordinal, its threat input starts from central baseline ratings that assessors may depart from with justification, and on this article’s reading most FSL factors are consequence and attractiveness proxies. ASIS standards, as publicly described, set out stages for establishing context and identifying, analyzing, evaluating and treating risk for organizations outside the federal rule. The implementation evidence covers FPS recommendations only, as of October 2023, and leaves more than half with unknown status, so it shows a gap without measuring its full size. Used well, either approach produces a reviewable argument that states its assumptions and records who accepted which risk. Controls examined elsewhere in this library, such as cloned access badges and master-keyed locks, are among the vulnerabilities such an argument has to cover.

Footnotes

  1. Interagency Security Committee, The Risk Management Process, 2024 Edition, sections 8.0 and 8.1 (Step One), Tables 2 to 8, pp. 18 to 33. https://www.cisa.gov/sites/default/files/2025-11/The_Risk_Management_Process_2024_Edition.pdf (opens in a new tab) ↩1 ↩2 ↩3 ↩4 ↩5 ↩6 ↩7 ↩8 ↩9 ↩10 ↩11 ↩12 ↩13 ↩14 ↩15 ↩16 ↩17 ↩18 ↩19 ↩20 ↩21 ↩22 ↩23 ↩24 ↩25 ↩26 ↩27 ↩28 ↩29 ↩30 ↩31 ↩32 ↩33 ↩34 ↩35 ↩36 ↩37 ↩38
  2. Interagency Security Committee, The Risk Management Process, 2024 Edition, sections 8.3 and 8.4 (Steps Three and Four, including 8.4.1 to 8.4.3 on risk acceptance and liability), pp. 39 to 48. https://www.cisa.gov/sites/default/files/2025-11/The_Risk_Management_Process_2024_Edition.pdf (opens in a new tab) ↩1 ↩2 ↩3 ↩4 ↩5 ↩6 ↩7 ↩8 ↩9 ↩10 ↩11 ↩12 ↩13 ↩14
  3. Interagency Security Committee, The Risk Management Process: An Interagency Security Committee Standard, 2024 Edition (Rev. 4.0, July 2024), DHS/CISA: change history, chair’s message, Updates, sections 1.0 to 7.0 (introduction, background, applicability, roles, training) and appendix list. https://www.cisa.gov/sites/default/files/2025-11/The_Risk_Management_Process_2024_Edition.pdf (opens in a new tab) ↩1 ↩2 ↩3 ↩4 ↩5 ↩6 ↩7 ↩8 ↩9 ↩10 ↩11 ↩12 ↩13 ↩14 ↩15 ↩16 ↩17 ↩18 ↩19 ↩20 ↩21 ↩22 ↩23 ↩24
  4. Executive Order 12977, Interagency Security Committee, signed 19 October 1995, 60 FR 54411 (24 October 1995), GovInfo facsimile. https://www.govinfo.gov/content/pkg/FR-1995-10-24/pdf/95-26497.pdf (opens in a new tab) ↩
  5. Executive Order 13286, Amendment of Executive Orders, and Other Actions, in Connection With the Transfer of Certain Functions to the Secretary of Homeland Security, signed 28 February 2003, 68 FR 10619 (5 March 2003), section 23, GovInfo facsimile. https://www.govinfo.gov/content/pkg/FR-2003-03-05/pdf/03-5343.pdf (opens in a new tab) ↩
  6. Executive Order 14111, Interagency Security Committee, signed 27 November 2023, 88 FR 83809 (1 December 2023), sections 5 to 8, official GovInfo PDF. https://www.govinfo.gov/content/pkg/FR-2023-12-01/pdf/2023-26569.pdf (opens in a new tab) ↩1 ↩2 ↩3 ↩4 ↩5
  7. Cybersecurity and Infrastructure Security Agency, ISC Standard: Risk Management Process (publication page linking the 2024 edition). https://www.cisa.gov/publication/risk-management-process (opens in a new tab) ↩
  8. General Services Administration, Federal Management Regulation; Physical Security, final rule, 87 FR 51915 (24 August 2022), effective 23 September 2022. https://www.govinfo.gov/content/pkg/FR-2022-08-24/html/2022-17950.htm (opens in a new tab) ↩
  9. General Services Administration, Federal Management Regulation; Aligning the Federal Management Regulation (FMR) With the Administration’s Deregulatory Priorities, final rule, 90 FR 58408 (16 December 2025), effective 16 December 2025 (Part 102-81 removed and reserved). https://www.govinfo.gov/content/pkg/FR-2025-12-16/html/2025-22915.htm (opens in a new tab) ↩
  10. General Services Administration, ratification of the FMR Case 2025-05 final rule, 91 FR 2314 (20 January 2026), signed 14 January 2026. https://www.govinfo.gov/content/pkg/FR-2026-01-20/html/2026-00928.htm (opens in a new tab) ↩
  11. Interagency Security Committee, The Risk Management Process: An Interagency Security Committee Standard, 2021 Edition, DHS/CISA, copy hosted by the Whole Building Design Guide. https://www.wbdg.org/FFC/DHS/isc_risk_mgmt_process_2021.pdf (opens in a new tab) ↩1 ↩2 ↩3 ↩4 ↩5 ↩6 ↩7 ↩8
  12. U.S. Government Accountability Office, Federal Facilities: Improved Oversight Needed for Security Recommendations, GAO-23-105649, 8 May 2023, with recommendation status notes. https://www.gao.gov/products/gao-23-105649 (opens in a new tab) ↩1 ↩2 ↩3 ↩4 ↩5
  13. Interagency Security Committee, The Risk Management Process, 2024 Edition, section 8.2 (Step Two: Identify and Assess Risk), pp. 33 to 39. https://www.cisa.gov/sites/default/files/2025-11/The_Risk_Management_Process_2024_Edition.pdf (opens in a new tab) ↩1 ↩2 ↩3 ↩4 ↩5 ↩6 ↩7 ↩8 ↩9 ↩10 ↩11 ↩12 ↩13 ↩14 ↩15 ↩16 ↩17 ↩18 ↩19 ↩20 ↩21 ↩22 ↩23 ↩24 ↩25
  14. Cybersecurity and Infrastructure Security Agency, Interagency Security Committee Policies, Standards, Best Practices, Guidance Documents, and White Papers (lists 2023 editions of FOUO Appendices A to C and access instructions). https://www.cisa.gov/standards (opens in a new tab) ↩
  15. U.S. Government Accountability Office, Federal Facility Security: Selected Agencies Should Improve Methods for Assessing and Monitoring Risk, GAO-18-72, 26 October 2017. https://www.gao.gov/products/GAO-18-72 (opens in a new tab) ↩1 ↩2 ↩3 ↩4
  16. Interagency Security Committee, The Risk Management Process, 2024 Edition, Appendix G.2 (Glossary of Terms: Level of Risk, Risk, Vulnerability). https://www.cisa.gov/sites/default/files/2025-11/The_Risk_Management_Process_2024_Edition.pdf (opens in a new tab) ↩1 ↩2
  17. Interagency Security Committee, The Risk Management Process, 2024 Edition, Appendix D (How to Conduct a Facility Security Committee, sections D.3.4 to D.4.2) and Appendix F (Example Risk Acceptance Justification Form). https://www.cisa.gov/sites/default/files/2025-11/The_Risk_Management_Process_2024_Edition.pdf (opens in a new tab) ↩1 ↩2 ↩3 ↩4 ↩5 ↩6
  18. 28 U.S.C. 2679(b), Exclusiveness of remedy (Federal Employees Liability Reform and Tort Compensation Act of 1988), Legal Information Institute. https://www.law.cornell.edu/uscode/text/28/2679 (opens in a new tab) ↩
  19. Interagency Security Committee, The Risk Management Process, 2024 Edition, section 8.5 (Step Five: Measure Performance) and section 9.0 (Compliance and Verification), pp. 49 to 51. https://www.cisa.gov/sites/default/files/2025-11/The_Risk_Management_Process_2024_Edition.pdf (opens in a new tab) ↩1 ↩2 ↩3 ↩4
  20. NIST, SP 800-55 Rev. 1, Performance Measurement Guide for Information Security (July 2008), publication page showing withdrawal on 4 December 2024 and supersession by SP 800-55 Vol. 1 and Vol. 2. https://csrc.nist.gov/pubs/sp/800/55/r1/final (opens in a new tab) ↩
  21. U.S. Government Accountability Office, Federal Protective Service: Actions Needed to Assess Risk and Better Manage Contract Guards at Federal Facilities, GAO-12-739, published 10 August 2012, publicly released 10 September 2012. https://www.gao.gov/products/gao-12-739 (opens in a new tab) ↩1 ↩2 ↩3
  22. U.S. Government Accountability Office, Federal Facilities: Continued Oversight of Security Recommendations Needed, GAO-24-107137 (testimony), 29 November 2023, pp. 6 to 9 and Figure 1. https://www.gao.gov/assets/d24107137.pdf (opens in a new tab) ↩1 ↩2 ↩3 ↩4
  23. FMLink, ASIS, RIMS release ANSI risk assessment standard, 21 October 2015. https://www.fmlink.com/asis-rims-release-ansi-risk-assessment-standard/ (opens in a new tab) ↩1 ↩2
  24. ANSI Webstore, ANSI/ASIS/RIMS RA.1-2015 Risk Assessment, product description, archived 10 November 2026. http://web.archive.org/web/20261110175840/https://webstore.ansi.org/standards/asis/ansiasisrimsra2015 (opens in a new tab) ↩
  25. ASIS International store, Security Risk Assessment Standard (ASIS SRA-2024), softcover listing, archived 8 April 2026. http://web.archive.org/web/20260408233447/https://store.asisonline.org/security-risk-assessment-standard-asis-sra-2024-softcover.html (opens in a new tab) ↩
  26. ASIS International, Introducing the ASIS Security Risk Assessment Standard: A Comprehensive Framework for Assessing Security Risks, press release, 16 April 2024, archived 28 October 2026. http://web.archive.org/web/20261028204418/https://www.asisonline.org/security-news/press-room/2024/security-risk-assessment-standard/ (opens in a new tab) ↩
  27. ASIS International, Security Risk Assessment Standard (standards and guidelines page), archived 8 May 2026. http://web.archive.org/web/20260508012214/https://www.asisonline.org/security-news/standards-guidelines/security-risk-assessment-standard/ (opens in a new tab) ↩
  28. ANSI Webstore, ASIS PAP-2021 Physical Asset Protection Standard, product description, archived 10 November 2026. http://web.archive.org/web/20261110175840/https://webstore.ansi.org/standards/asis/asispap2021 (opens in a new tab) ↩
  29. 32 CFR 2001.43, Storage (classified national security information), in the official eCFR XML for Title 32, Part 2001, as of 24 November 2026. https://www.ecfr.gov/api/versioner/v1/full/2026-11-24/title-32.xml?part=2001 (opens in a new tab) ↩1 ↩2
  30. 32 CFR 2001.92(s), Definitions: security-in-depth, in the official eCFR XML for Title 32, Part 2001, as of 24 November 2026. https://www.ecfr.gov/api/versioner/v1/full/2026-11-24/title-32.xml?part=2001 (opens in a new tab) ↩
  31. Mary Lynn Garcia, Risk Management, SAND2004-6286P, Sandia National Laboratories (author note: Principal Staff Member at Sandia). https://www.osti.gov/servlets/purl/1728532 (opens in a new tab) ↩
  32. Mary Lynn Garcia, Design and Evaluation of Physical Protection Systems, 2nd edition, Elsevier (Butterworth-Heinemann), 26 September 2007, publisher’s page. https://shop.elsevier.com/books/design-and-evaluation-of-physical-protection-systems/garcia/978-0-08-055428-0 (opens in a new tab) ↩
  33. Harold A. Bennett and Dallas W. Sasser, EASI Program Improvements for HP-67 and TI-59 Calculators, NUREG/CR-0350, SAND78-0506, Sandia Laboratories for the U.S. Nuclear Regulatory Commission, August 1978, Sections I and II and Appendix A. https://literature.hpcalc.org/community/hp67ti59-easi.pdf (opens in a new tab) ↩1 ↩2 ↩3 ↩4
  34. Sandia National Laboratories, 16. Evaluation of Physical Protection Systems, SAND2007-5502P, chapter from The Twentieth International Training Course, 2007, sections 16.2 to 16.4. https://www.osti.gov/servlets/purl/1721450 (opens in a new tab) ↩1 ↩2 ↩3 ↩4 ↩5
  35. Louis Anthony Cox Jr., What’s wrong with risk matrices?, Risk Analysis 28(2):497-512, April 2008, doi:10.1111/j.1539-6924.2008.01030.x, abstract on PubMed. https://pubmed.ncbi.nlm.nih.gov/18419665/ (opens in a new tab) ↩1 ↩2
  36. National Research Council, Review of the Department of Homeland Security’s Approach to Risk Analysis, National Academies Press, 2010, Summary. https://www.nationalacademies.org/read/12972/chapter/2 (opens in a new tab) ↩1 ↩2
  37. Louis Anthony Cox Jr., Some limitations of “Risk = Threat x Vulnerability x Consequence” for risk analysis of terrorist attacks, Risk Analysis 28(6):1749-1761, December 2008, doi:10.1111/j.1539-6924.2008.01142.x, abstract on PubMed. https://pubmed.ncbi.nlm.nih.gov/19000071/ (opens in a new tab) ↩1 ↩2
  38. 10 CFR 73.1, Purpose and scope (design basis threats), in the official eCFR XML for Title 10, Part 73, as of 24 November 2026. https://www.ecfr.gov/api/versioner/v1/full/2026-11-24/title-10.xml?part=73 (opens in a new tab) ↩