Abstract
Can someone who holds one ordinary key to a master-keyed building, and can use the lock it opens, turn it into a key for the other doors in the same master system? In 2003 Matt Blaze showed that for conventional split-pin systems, where change and master keys share one shear line and pin positions are mastered independently, the answer is often yes. Such a lock accepts any key whose cut at each position matches either the change depth or the master depth, so its accept-or-reject decision exposes the higher-privilege bitting, position by position, to someone holding a matching key and lock. The work then grows with the sum of the choices at each position, not their product. With owners’ cooperation, Blaze recovered the top master key on all ten institutional systems he tested, which shows the result held there, not how common such systems are today. Locksmiths answered that the method was old trade knowledge and too dangerous to publish. Cylinders that give the master its own shear line avoid this exposure. Restricted keyways raise the cost only where blank control holds. Operators can keep master systems small and keep sensitive doors off them.
A lock that is also an access-control list
A master-keyed building encodes an access policy in brass. Each office door should open for its occupant’s key, a floor’s doors for the floor master, and every door for the top master key held by facilities staff. Matt Blaze, then at AT&T Labs, framed the security question in computing terms in a paper written in 2002 and published in IEEE Security & Privacy in March/April 2003. He asked whether a user holding a low-privilege credential can amplify it into a high-privilege one.12 He wrote that master key systems “should resist unauthorized rights amplification (also called privilege escalation)”, and that “most deployed master key systems are quite vulnerable in this regard.”3
The weakness lies in the keying scheme, so better manufacturing does not remove it. In his notes on lock picking, Blaze contrasted picking, which exploits “small manufacturing imperfections”, with weaknesses “in the keyspaces of master keyed systems, which are independent of the physical qualities of the locks themselves”.4 A perfectly made cylinder, pinned in the conventional split-pin way, still carries information about the master bitting.
The finding has a scope. Blaze’s attack targets locks “that have a single shear line used by both master and change keys”, keyed by the standard schemes he describes, and to someone with access to a change key and its matching lock.53 His fact sheet puts the condition as access to one of the locks in the system and possession or prior examination of its key.6 What a derived master opens is the set of doors in that master domain. Cylinders built differently, doors keyed outside the system, and systems that do not use master keying at all fall outside the finding.
Pin tumblers in brief
A pin tumbler cylinder has a rotating plug inside a fixed shell. Spring-loaded pin stacks sit in holes drilled through both. With no key inserted, the stacks cross the boundary between plug and shell, called the shear line, and stop the plug from turning. A key lifts each stack. The plug turns only when every stack has a break exactly at the shear line. If a stack is lifted too little or too far, the plug stays locked.1 How the manufacturing tolerances in such a cylinder are exploited by picking and bumping is a separate subject, treated in How pin tumbler locks are opened.
The key’s cut depth at each position is its bitting. Manufacturers use a small number of standard depths, so a key can be written as a short string of digits from shoulder to tip. Blaze gives typical ranges of four to seven pins and four to ten depths.1 Schlage’s service manual for its Everest cylinders documents one configuration: ten root depths numbered 0 to 9, six cut positions, a two-step progression and a Maximum Adjacent Cut Specification (MACS) of 7.7 MACS is “the maximum allowable difference between adjacent cut depths”, a limit that exists because a very deep cut beside a very shallow one removes metal the shallow cut needs.8
Three different numbers describe such a lock, and they are easily confused. The nominal bitting space is the number of depths raised to the number of positions: 10⁶, or one million, for six positions and ten depths, before MACS and other physical rules remove combinations.1 The theoretical issue capacity is how many distinct change keys a keying scheme can hand out; Schlage gives “4,096 theoretical changes per keyway using two step progression” for the Everest family.7 The acceptance set of one cylinder is the set of bittings that actually turn it. In the idealized single-keyed model, where each stack has one break, that set holds one bitting.1
How split-pin master keying works
Master pins and the single shear line
The usual way to master key a pin tumbler lock is to put a short extra segment, a master pin, into a stack. The trade glossary defines it as a pin “placed between the top and bottom pin to create an additional shear line.”8 Physically, the cylinder still has one plug shear line. What the master pin adds is a second break in the stack, so two different lift heights put a break at that one line: the change key’s depth and the master key’s depth. Blaze’s toy example uses a five-pin lock A whose every stack is split for depths 1 and 4. It opens with change key 11111 and with master 44444. A second lock B, split for 2 and 4, opens with 22222 and 44444.1
Split-pin mastering is widespread, though no source cited here measures its share of installed locks. William Lynk, an interchangeable-core specialist who wrote a book on the less common positional method, gave his own estimate to Locksmith Ledger in 2022: “90% of everything out there is using split-pin.”9 That is one practitioner’s opinion, not a survey.
Key bitting arrays and progression
Locksmiths do not choose change keys at random. They start from the top master key (TMK) and build a key bitting array (KBA), “a matrix (graphic) display of all possible bittings for change keys and master keys as related to the top master key.” Change keys are generated from its columns by progression, which the glossary describes as “a logical sequence of selecting possible key bittings, usually in numerical order”; the order is a convention of the particular system.8
Tom Gillespie described the two-step version in Locksmith Ledger in 2010. “If a MK cut is an even number in the first chamber, all cuts used in the first chamber will be even.” Five depths of that parity remain, one belongs to the master, and four are left for change keys at that position.10 Progressing all six positions gives 4⁶ = 4,096 theoretical change keys, matching Schlage’s figure.107 Gale Johnson, editor emeritus of the same magazine, wrote that Sargent, Yale and Schlage “used a 10 depth increment system and a two-step progression”, which suited the “hold & vary” layout.11 These are documented examples, not a ranking of what is most common.
Total position progression and rotating constant
Blaze identified two standard schemes, and his attack covers both.1
In total position progression (TPP), “bittings of change keys differ from those of the top master key in all bitting positions.”8 In Blaze’s description, every pin stack has “a single separate master cut, which is never used in that position on any change keys.”1
In the rotating constant method (RC), “at least one cut in each key is identical to the corresponding cut in the top master key,” and the constant position moves from key to key.8 Johnson gives theoretical figures for a five-pin RC system with four KBA choices per position: 256 differs for each of five rotation groups, or “1280 theoretical total differs”, against 1,024 for five-pin TPP.11 A table in a 2016 Locksmith Ledger article on Medeco master keying lists 2,148 change keys for RC with one constant against 2,048 for TPP in a five-pin Medeco system, with fewer master pins under RC. The table does not give enough parameters to compare it directly with Johnson’s example.12
The two schemes also differ in what a group of key holders can learn without touching a lock. Under TPP the master’s depth never appears on a change key at that position, so, as Blaze notes, “a conspiracy of key holders may discover a single depth not used at each pin position”, a trick correspondents reported among “enterprising university students”. The inference does not apply to RC, where change keys carry master cuts.1 Benjamin Laxton, Kai Wang and Stefan Savage showed in 2008 that a key’s bitting can be read from a photograph, so the information on a key is exposed whenever the key is visible. They also restated the omission observation for many master systems.13
What master keying gives up
The trade does not claim master keying is free. Gillespie wrote that “master keying is a controlled loss of security” and that “each additional shear line added further reduces the security level.”10 The losses take several forms.
Accepted combinations. In an idealized TPP cylinder with a master pin in all six chambers, each position has two allowed depths, so the cylinder accepts up to 2⁶ = 64 bittings, not two. Blaze’s five-pin lock A accepts 2⁵ = 32.3 The maximum assumes every modeled position has two distinct allowed values and ignores key geometry. The glossary calls an unplanned working combination an incidental master key: “a key cut to an unplanned shear line created when the cylinder is combinated to the top master key and a change key.”8 Planned group keys and unplanned acceptance are different things. Gillespie describes how a properly progressed system uses some of these combinations as deliberate sub-masters for groups of doors, and writes that “You can’t eliminate these mathematical shear lines that allow these sub-masters to operate.”10 The combinations that are not assigned to anyone remain residual, unintended acceptance.
Key interchange and cross keying. Key interchange is “an undesirable condition, usually in a master key system, whereby a key unintentionally operates a cylinder or lock.” The glossary’s note on cross keying warns that it “could severely limit the security of the cylinder.”8 Gillespie describes common doors loaded with stacks of master wafers so that every occupant’s key works, and writes that “A 6-pin lock with that setup can actually have thousands of shear lines! Almost any key inserted will open the lock.”10 His “shear lines” is trade shorthand. The cylinder still has one plug shear line; what multiplies is the number of break combinations that can sit at it.
Manipulation. Blaze notes that because mastered stacks align at several heights, “mastered locks tend to be more vulnerable to manipulation by picking and impressioning.”1
Blaze’s background section lists the master key itself as “a very valuable target” whose compromise “compromises the entire system.”1 His paper added that, in this family of locks, information about the master bitting is also present in every cylinder that a master opens.
What the lock tells a key holder
Threat model
The threat is defined by access, not by role: someone with a change key and access to the lock it opens. That person is usually an authorized insider, but need not be. Marc Weber Tobias, a lock consultant to law enforcement, told the New York Times in January 2003 that an insider was the most likely attacker; the paper reported that he also thought an outsider who borrowed a key to a shared room, such as a restroom, could use the method.14 Blaze’s fact sheet extends the condition to people who have previously examined a key, not only current holders.6
An oracle that answers one position at a time
Blaze describes the lock in the vocabulary of cryptanalysis.
From a cryptologic point of view, we might observe that a lock is really an online “oracle” that accepts or rejects keys presented to it.3
The oracle gives one bit per query: the plug turns or it does not. On its own that sounds harmless, since one bit per try is exactly what an ideal lock gives. What matters is which question the bit answers. “There is no ‘communication’ among pins,” Blaze writes, so a split-pin cylinder turns for any key that aligns each stack at either of its breaks, with some stacks at the change depth and others at the master depth.3 The acceptance rule is checked position by position, independently.
Independent per-position acceptance means that, in the studied design, the cylinder’s decision carries information about each position separately, and someone who holds a matching key and lock is in a position to receive it. Blaze’s paper calls the resulting analysis an “adaptive oracle” attack that recovers the TMK “pin by pin”.3 Nothing in this requires the lock to malfunction. The exposure is in the intended accept-or-reject decision. Geometry, non-standard depths and extra breaks can make particular answers ambiguous or unavailable, as the limits below describe.
Multiplicative versus additive, in counts
The size of the effect is easiest to see as arithmetic. In Blaze’s notation a lock has P pin positions and D standard depths, so the nominal bitting space has Dᴾ members.3 A blind search over that space has to deal with every position at once: the number of candidates is the product of the choices at each position.
Independent per-position answers change the product into a sum: at most D − 1 alternatives at each of P positions, which Blaze gives as a worst case of P(D − 1) queries.3 For an illustrative six-position, ten-depth model the two growth rates give:
| Search | How the count grows | Six positions, ten depths |
|---|---|---|
| Blind search of the nominal space | product, Dᴾ | 1,000,000 |
| Per-position oracle, worst case | sum, P(D − 1) | 54 |
Both rows are counts in Blaze’s idealized model, and the comparison is between growth rates, not a prediction of effort on a real system. The product row is the raw nominal space before keying conventions and physical rules shrink it. The sum row assumes standard depths, that every candidate can be tested, and that each answer is unambiguous. Blaze’s own summary was that testing one key bit independently of the others would make a cryptosystem “hopelessly insecure, since an attack would take time only linear in the number of key bits, instead of exponential”.15
Blaze reported in 2003 that the blanks used in his trials came from standard commercial sources, and he treated blank availability as the main practical question for restricted and high-security designs.1617
Limits on the published finding
Section 3.2.3 of Blaze’s paper lists conditions that complicate the clean model.17
- Physical constraints. Under a MACS rule, some keys that mix change and candidate master cuts are not legal bittings, so some combinations in the nominal space cannot be used or tested at all.
- Non-standard depths. Older or privately rekeyed systems may put master cuts between the manufacturer’s standard depths, which enlarges the set of possibilities at a position.
- Multiple breaks per stack. Where sub-masters are built by adding further breaks to some stacks, a single lock can leave the master cut at those positions ambiguous, so one lock may not determine the master at all.
- Sectional (multiplex) keyways. Large systems sometimes place groups of locks on different keyways and cut the TMK on a master blank that fits all of them. Blaze calls these “especially attractive targets”, because a master in such a system reaches across sections.
Some of these conditions only enlarge the problem. Others, such as extra breaks, limit what a single lock can reveal at all. None of them changes the independent per-position acceptance on which the finding rests.
What Blaze found in the field
Blaze tested the attack, with the owners’ cooperation, on institutional systems built from Arrow and Best small-format interchangeable cores (SFIC), Corbin Russwin, Schlage and Yale hardware.16 He reported that “In every case, the attack yielded the top master key bitting” and that in general it took only a few minutes, even when keys were cut by hand.16 By his account, all six SFIC systems used TPP with every stack mastered; the two Corbin Russwin System 70 installations mastered three of six stacks under TPP; the Schlage system was RC-based with every pin mastered and two master cuts on each change key; and the Yale system was RC-based with one.16 He reported that he did not encounter more than one master cut per pin stack, selective keying or non-standard master depths in these systems.16
Blaze cautioned that the experiments “hardly constitute an exhaustive survey”, though the sites “seem reasonably representative of a large segment of US institutional lock installations.”16 Ten systems tested for a 2002 preprint show that the attack worked where it was tried. They are not a measure of how many master systems in 2026 share the vulnerable design.
Why this is an oracle attack
A product of small sets
The structure is clearer written out, in an idealized model that ignores key geometry and secondary mechanisms. Let a cylinder’s acceptance set be the set of bittings that turn it. In a split-pin cylinder where stack i has breaks at change depth cᵢ and master depth mᵢ, that set is a Cartesian product:
{c₁, m₁} × {c₂, m₂} × … × {cₚ, mₚ}
The owner wants the lock to accept two points, c and m. Because each position checks its own condition, the lock accepts every combination of them, up to 2ᵖ where every position has two distinct values, and its decision can be informative about one coordinate at a time.
Blaze drew the same conclusion. “One of the first questions asked about any proposed cryptosystem,” he wrote, “is whether it is possible to test the value of one key bit independently from the others.” In the lock, a pin stack takes the place of a key bit.15 The general lesson concerns decomposable secrets: when a verifier checks a secret part by part, its strength can fall to roughly the sum of the parts’ strengths, even if it reports only overall success.
Two cryptographic relatives
Blaze himself named the closest precedent, saying his scheme “bears a striking resemblance to a famous character-by-character attack against the Tenex password mechanism.”15 Butler Lampson described it in his 1983 paper “Hints for Computer System Design”. The Tenex CONNECT call compared a directory password one character at a time, and a combination of features meant that a page-fault report to the user program revealed whether a prefix of a guess was correct. Lampson wrote that the trick finds a password of length n in 64n tries on average, rather than 128ⁿ/2.18 The second figure is exponential in the password length; the first is linear.
The padding oracle is the second relative, and it is related more loosely. John Black and Hector Urtubia, at USENIX Security in 2002, summarised Serge Vaudenay’s attack on CBC-mode encryption. Given an oracle “which reveals whether or not the plaintext (corresponding to some altered ciphertext) is correctly padded,” an attacker can recover the plaintext, decrypting a block “in about 128b expected oracle queries” where b is the number of bytes per block.19 The oracle answers a predicate about padding, and those answers together reveal plaintext. The secret key is never checked in pieces. Black and Urtubia placed the attack beside Bleichenbacher’s earlier work on RSA PKCS #1 and argued for encryption schemes that also provide integrity of ciphertexts.19
What the three cases share is inference from partial information. Each system answers a narrow question whose answers, taken together, reveal something structured: a password, a plaintext, a master bitting.
Where the analogy is loose
The comparisons stop being exact in three places.
First, the master key attack needs no side channel. Tenex leaked through a page-fault report that the designers never meant as output.18 Vaudenay’s attack needs padding validity to be distinguishable by the attacker in some way; Black and Urtubia note that implementations differ, some returning an error and others only logging it.19 The lock’s only output is its intended one, whether the plug turns. The flaw is in the acceptance rule itself, so hiding information more carefully would not fix it. The lock has to accept a different set.
Second, the attacker starts with a credential. A padding-oracle attacker holds no key. The lock attacker holds a valid key and is trying to widen it. The nearest computing analogue is privilege escalation by an authenticated user, which is how Blaze framed it.3 Blaze also compared the TPP conspiracy of pooled change keys to related-key attacks and to traitor tracing.15
Third, the costs and defences differ. Tenex imposed a three-second delay after a wrong password.18 A conventional, unaudited mechanical cylinder of the kind Blaze studied has no rate limit, lockout or record of attempts, and Blaze notes that a compromise may go undiscovered.15 Trap cylinders, discussed below, are one mechanical exception. Electronic access control can add logging, expiry and revocation, which changes what an operator can detect, though it brings failure modes of its own.
The same shape in safe locks
Blaze’s 2004 draft survey “Safecracking for the computer scientist” found a similar decomposition in mechanical combination locks, this time through a true side channel. Manufacturing imperfections can let a manipulator learn about individual wheels from the feel of the dial. Where each wheel can be mapped separately, he counts at most 203 trial combinations for a three-wheel lock with 66 positions, against 287,496 under naive search.20 He describes UL Group 1 locks as “intended to resist expert manipulation for at least twenty hours; in practice this means the best attack against such locks should be exhaustive search.”20 That is a design objective for resisting manipulation. The contrast with master keying is the source of the leak. A safe lock leaks through physical imperfections that designers try to suppress. A split-pin master system leaks through its ordinary access decision.
Publication and the trade
January 2003
Blaze’s preprint is dated 15 September 2002, and the IACR Cryptology ePrint Archive records receiving it on 23 October 2002.121 His fact sheet, dated 16 January 2003, says that since the research was completed “we have been quietly circulating details of the vulnerability to the lock, law enforcement, and security communities.” It adds that “there is some evidence that the details are now circulating in the underground world” and that “more good than harm would now be done by warning the wider community”.6
John Schwartz’s story in the New York Times ran on 23 January 2003. It reported that AT&T had posted an alert to law enforcement agencies and, according to Schwartz, that the alert said a prepublication version distributed privately for review had leaked onto the Internet. The alert itself is not available for inspection here; the account of it is Schwartz’s.14
The story set out the positions that would define the argument. Lloyd Seliber, head instructor of master-key classes for Schlage, said the technique was not news to locksmiths and that he taught it, calling it “decoding”, and that it had “been true for 150 years”. The Times added that variations had appeared in trade journals, “usually as a way for locksmiths to replace a lost master key and not as a security risk.” Tobias replied: “He may teach it, but it’s new in the security industry. Security managers don’t know about it.” Tobias also said that he had given instructions and materials to a 15-year-old, who made a working master key.14 Ed Felten gave his own judgment the same day: “Schlage has even taught locksmiths how to carry out a version of Blaze’s attack. Yet somehow they never bothered to tell their customers.”22
Blaze never claimed to be first. His paper says the attack “surely is not new in this sense,” mentions a 1987 message by Doug Gwyn to a private mailing list describing a similar method, and notes that there “do not appear to be references to this particular attack in the published literature of either the locksmith or underground communities.”3 He told the Times: “I don’t think I’m the first person to discover this attack, but I do think I’m the first person to work out all the details and write it down.”14
“Keep it secret, stupid!”
On 26 January 2003 Blaze posted an essay to comp.risks and the Interesting-People list, now kept on his site, describing his inbox:
For a few days, my e-mail inbox was full of angry letters from locksmiths, the majority of which made both the point that I’m a moron, because everyone knew about this already, as well as the point that I’m irresponsible, because this method is much too dangerous to publish.23
He called the episode “a classic instance of the failure of the ‘keep vulnerabilities secret’ security model.” He wrote that he had been told the industry had known about the vulnerability “for over half a century” and kept it as folklore, “sometimes used as a shortcut for recovering lost master keys for paying customers.”23 His sharper complaint was about the market: “It’s a pity that stronger alternative designs have been allowed to die a quiet death in the marketplace while customers, ignorant of the risks, have spent over fifty years investing in inferior systems.”23
Bruce Schneier’s column in the same issue of IEEE Security & Privacy reported that “the locksmith community went ballistic.” He argued that secrecy keeps customers from assessing their own risk: “many customers might have decided not to use master keying if they knew how easy it was for an attacker to make his own master key.”24
The friction continued. Blaze put a first draft of his safe-lock survey online in December 2004.20 In an essay dated 19 January 2005 he described a similar response. He wrote that some locksmiths “do not approve of disclosing vulnerabilities in locks to the ‘general public,’ on the grounds that open discussion aids the bad guys more than it helps the good guys.” He also reported that some locksmiths had apparently tried to organize a letter-writing campaign to officials at the University of Pennsylvania, where he then worked, and that he had been told several officials received letters.25
Hobbs in 1853
Blaze published, alongside the fact sheet, a passage from the Rudimentary Treatise on the Construction of Locks, edited by Charles Tomlinson from material supplied by A. C. Hobbs and first published in 1853. Blaze calls Hobbs one of the nineteenth century’s “foremost inventors of mechanical locks.”26 The scanned page of the treatise reads:
Many well-meaning persons suppose that the discussion respecting the means for baffling the supposed safety of locks offers a premium for dishonesty, by shewing others how to be dishonest. This is a fallacy. Rogues are very keen in their profession, and know already much more than we can teach them respecting their several kinds of roguery.27
The passage continues on the next page that “the dishonest are tolerably certain to be the first to apply the knowledge practically”. Blaze’s transcription reads “tolerably certain to apply the knowledge practically”, without the words “to be the first”.2726 Blaze set beside it an excerpt, quoted on his page, from a 1953 safe manipulation text by Clyde Lentz and Bill Kenton, which advised readers to “destroy this book completely, so as to protect yourself and our craft.” He commented that the dearth of open literature “now makes it quite difficult for a potential user to be sure whether or not a given lock suffers from known attacks.”26
The objections that deserve weight
The objections rest on different kinds of evidence.
Prior knowledge. Practitioners did know versions of the method. Seliber said he taught it, the Times found variations in trade journals, Blaze cited Gwyn’s 1987 message, and Blaze’s correspondents reported student use.1431 On the cryptography mailing list, Donald Eastlake called the Times piece “a ridiculously overhyped teaser article about a very simple 150 year old weakness.”28 Bram Cohen asked whether Blaze had consulted a single locksmith before calling the attack new; Blaze answered, “Of course I did. What gave you the idea that I didn’t?”2930 What the evidence does not show is how widely the method was understood as a risk by the people who bought and ran master systems. Tobias’s view was that security managers did not know. Seliber’s classes and the trade-journal mentions framed it as a lost-key service.14
Cost of disclosure. For this vulnerability, the Times noted, “for the most part, locks must be changed mechanically, one by one.”14 Cohen also asked whether Blaze had compared the production costs of more secure designs and how often lock attacks happen in practice.29 Those costs and incident rates were not measured for any site, then or in the sources here. The security value of disclosure lies elsewhere: Blaze argued that “there’s no way of knowing whether the bad guys know about an attack,” and that publication “puts the good guys and the bad guys on equal footing.”14
Who learned what, when. The record is uneven. Blaze’s fact sheet speaks of “some evidence” of underground circulation; Schwartz reports the alert’s statement about a leaked preprint; Blaze’s essay reports folklore he was told about.61423 None of this establishes when particular groups learned the method. The press and mailing-list reporting is best read as evidence of the disclosure debate and the differing claims made in it.
An accepted trade-off. Gillespie’s “controlled loss of security” is an honest description from inside the trade.10 Seliber told the Times that Schlage recommended patented keyways to architects and builders, which he said added 1 to 2 percent to the cost of each door. According to the paper, he said builders were often told not to worry about such elaborate threats and to take a cheaper route.14 A trade-off is only accepted in a meaningful sense if the buyer knows what is being traded. Blaze’s result was that, in these systems, a change key together with access to its lock is a step toward the master, not only a key to one door.
What mitigates it, and what does not
Designs that avoid the per-position feedback
Blaze states that his “adaptive oracle attack is only effective against locks that have a single shear line used by both master and change keys.”5 Several older designs avoid that property in different ways.
Master ring cylinders. A ring between plug and shell creates a second, outer shear line. In Blaze’s description, the stacks must all be aligned “to the same one of two distinct master or change shear lines,” and therefore “do not provide feedback about the master bitting of a pin given the change bittings of the other pins.”5 In the idealized two-key example, the acceptance set becomes the two intended points instead of their product, so a key mixing change and master cuts is rejected. Richard Howard traced the design, in the ALOA magazine Keynotes in May 2021, to New York locksmith Edward O’Keefe, who assigned the patent to P. F. Corbin.31 That patent, US 414,720, was issued on 12 November 1889.32 Howard writes that the design addresses “the ability to provide a master-keyed cylinder without key interchange.” In its mortise form the cylinder is 1½ inches in diameter and is nicknamed the “jumbo cylinder.”31 Blaze warns that master ring locks “are actually more vulnerable to reverse engineering from lock disassembly by an attacker without access to the change key.”5
Bicentric cylinders. Howard compares the master ring to “the Yale Bicentric cylinder”, which he says was intended “to isolate master key bittings from change keys and prevent key interchange.”31 Blaze wrote that master rings and bicentric locks “resist completely the adaptive oracle attack described in my paper”, while granting that “these designs aren’t perfect”.23
Positional master keying. In these systems, each lock leaves some of a larger number of possible tumbler positions empty, higher-level keys need more cuts, and no master pins are used.9 Blaze writes that positional schemes “cannot be decoded in this manner (but, again, are still vulnerable to other attacks).”5 Lynk’s 2022 account covers both pin or dimple systems and magnetic ones. Of the positional keyways in his book, he said only Sargent Keso remained in production, Kaba Gemini had evolved into dormakaba Gemini Plus, sold mostly in Europe, and the magnetic Miwa EC and Schlage CorKey had not been sold for decades.9 Sargent’s website carries a product page for the Keso F1 system, which shows a listing, not stock or lead times.33
Practitioners disagree about picking. Len Sassaman argued on the cryptography list that master ring systems “often make the task of picking the lock (on a case by case basis) easier.”34 Blaze replied that they make it “considerably harder”, because a pin may set at either shear line and the lock opens only if all stacks catch at the same one, while agreeing that adding false cuts “does increase picking vulnerability”.35 Howard describes the master ring as “commonly understood, on average, as more time-consuming and resistant to picking and impressioning.”31 These are judgments about particular designs, not test results.
The market history is dated. In January 2003 Blaze found master rings still “listed as an option in the Corbin-Russwin catalog for a few commercial cylinders.”35 His paper said a few master ring locks “are still commercially manufactured, but the design has largely fallen out of favor for most applications.”5 Howard’s 2021 article describes a Corbin Russwin master ring mortise cylinder and the service kits for it.31
False cuts
Blaze proposed a countermeasure for conventional cylinders: add a further “false” break to some stacks, one that matches neither the master nor most other locks. The lock still answers turn or no turn, but at a stack with a false cut more than one non-change depth works, so a single lock yields several candidate masters, only one of which is real.5 The trade-off is unintended acceptance. Each false cut widens the cylinder’s acceptance set, creating new groups of keys that open it, and Blaze writes that “each such cut reduces the number of unique differs available in the system.” He also agreed that false cuts increase picking vulnerability, and concluded that the approach “may not be a useful or safe countermeasure on conventional locks with a small number of pins.”535
Restricted and patented keyways
Restricted keyways do not change the acceptance rule; they aim to keep blanks out of reach. Blaze’s 2003 view was that this “may offer only the appearance of protection,” because many restricted blanks were available from aftermarket sources and others could be fabricated.65 Ben Burgess, Eric Wustrow and J. Alex Halderman showed in 2015 that 3D-printed keys could operate several commonly used pin-tumbler locks they tested, with durability that varied by material and keyway, and they listed privilege escalation in master-keyed systems among the attacks this lowers the bar for.36 At DEF CON 21 in 2013, David Lawrence, Robert Johnson and Eric Van Albert reported 3D-printing working keys for the Schlage Primus.3738 These results concern the products and conditions studied.
Where blank control actually holds for a product, restricted keyways raise the effort needed; how well it holds varies by product and over time. Blaze notes that many manufacturers and locksmiths believe patented keys with no legal blanks deter most casual attackers, and that judging that belief means considering “future industry behavior and the likelihood of the continued validity and enforcement of the patents.”5 Patents expire. Locksmith Ledger reported in 2008 that “The original Schlage Primus patent expired in 2007.”39
Sidebars and secondary locking
High-security cylinders often add a second locking mechanism. In the Medeco design patented in 1970, US 3,499,302 by Roy Spain and others, the key must both lift and rotate each tumbler so that a fence can be cammed out of engagement.40 The Schlage Primus adds five spring-loaded finger pins, set by side millings on the key, that operate a sidebar.39 Against rights amplification, Blaze wrote that “even ‘high security’ pin tumbler lock designs, including those that use sidebar cuts and rotating pins, are usually in principle vulnerable to this attack; the only question is whether the attacker can obtain or fabricate the required blanks.”17
Blaze’s assessment applies most directly where the secondary mechanism accepts the change key’s own coding throughout, so that it never distinguishes change from master. Then the sidebar authorizes the change credential and the blank is the obstacle. Other configurations add conditions. The Medeco trade article describes master keying applied to a secondary element: “master-keying on the slider”, where “the slider must be unlocked at the same time as the pin stacks in order to unlock the cylinder fully.”12 The sources cited here do not establish whether such a combined system exposes its elements independently, so its resistance to this attack is an open question for any particular product.
Trap cylinders
Burgess and colleagues describe a less common option: cylinders configured to “trap” particular keys. Telescoping pins expand into small trap holes when a forbidden bitting is used, so the lock neither turns nor releases the key. They propose that such locks “could also be used to prevent rights elevation and bumping attacks.”36 Unlike a false cut, which leaves the answer as turn or no turn, a trap can keep the key in the lock. The paper presents this as a proposed application and reports no field evidence of it preventing an attack.
Interchangeable cores
Small-format interchangeable cores (SFIC) did not resist the attack in Blaze’s tests; all six SFIC systems yielded their TMK.16 What they offer is a recovery capability. An interchangeable core is one for which “No tools (other than the control key) are required for removal of the core,” so a site can swap a core without removing the lock hardware. The glossary establishes removal with the control key; it gives no comparison of recovery times.8 Cores add a third credential, the control key, which operates a separate control shear line in cores combinated to it.8 None of the sources cited here analyses whether a control key leaks through the same per-position feedback.
Standards ratings
Ratings test different threats, and each standard’s public material should be read on its own terms. UL’s catalogue describes UL 437 as covering key locks, including door locks and locking cylinders.41 A 2009 Lockwiki summary describes its attack-resistance tests and a requirement that door locks and cylinders provide at least 1,000 key differs; that summary is a third-party description and may not reflect the current edition.42 BHMA’s public summary of ANSI/BHMA A156.30-2025 for high-security cylinders lists key control attributes including “key blank control”, and surreptitious tests covering “minimum key changes” and “mechanical pick resistance through either decoding or picking.”43 The companion recommended practice, A156.28, covers keying-system design and key management for building owners.44
None of these public summaries describes a test in which a key holder derives a master key from their own lock. The full standards were not available for this article, so the narrower point is that the public material does not establish resistance to this attack. A rating is evidence of the properties tested. It does not change the cylinder or the attacker’s cost, and it does not describe how a master system built from such cylinders behaves against its own key holders.
Electronic and electromechanical systems
In electronic access control, the authorization decision is made by the electronic layer, a reader, controller or cylinder logic, not by a product of pin heights, so that layer does not have this particular structure. It has failure modes of its own, covered in our article Cloning the badge: how electronic access credentials fail, and what to deploy instead.
Electromechanical systems sit in between. In the “Cylinder function” section of its technical guide for PROTEC² CLIQ, ABLOY describes a nine-disc PROTEC² mechanism with an electronically controlled blocking element. When an authorised key is inserted, the key’s battery powers the release, and “Both cylinder audit trail and key audit trail are stored simultaneously.”45 The two records are collected by different routes: cylinder audit trails with a programming key, key audit trails during remote updates of the key.45 Revalidation, described in the software section, is a key-side validity setting: a key must be refreshed at a remote programming device within a set interval, and if it is not, it “becomes inactive until it is revalidated again.”45 Withdrawing a lost key’s electronic rights therefore takes effect when its validity lapses, or at once for keys using the guide’s online opening feature, where access rights are checked in real time.45 The guide also says the CLIQ key can operate mechanical PROTEC cylinders with eleven discs.45 Those cylinders have no electronics to check validity, so a lost key’s mechanical coding keeps working on compatible mechanical doors until they are changed. An audit entry records a credential event at a cylinder. It is not by itself proof that a door was opened, or of which person held the key.
Scope reduction
The first defence on Blaze’s fact sheet is to “Eliminate the use of master keying entirely,” with “locked key control cabinets” as a workable alternative in smaller environments. Failing that, he recommends separating “different functions into different master systems” so that a successful attack opens less.6 The Medeco trade article gives related advice from inside the trade: single-keyed cylinders where possible, constants to reduce the number of master pins and shear lines, and a dedicated key instead of cross keying.12 Fewer master pins and more constants reduce incidental keys, but they leave the system within the family that Blaze’s attack covers, since his method also works against RC systems.3
Rekeying
Rekeying retires a compromised credential across the domain it is applied to: once the affected master domain is rekeyed, the old master no longer works there. It does not help against a compromise nobody has noticed, and Blaze notes that a compromise may not be discovered. Remedying one means rekeying every mastered lock in the domain, which takes time “during which all the old locks remain exposed.”15 If the same cylinder design is kept, the structural exposure remains for the new keys. The scope of a compromise is the domain that the derived master opens: a sub-master’s doors, a building, or every section of a multiplex system.
Institutional key policies tend to price loss. The University of Connecticut’s key policy, in the revision posted in September 2023, is one example. It leaves Locksmith Services to “determine if and when locks need to be changed as a result of a lost key(s).” Its schedule lists a key-replacement charge and, where a lock change is performed, $100 per cylinder; for a lost building master key, the “actual cost re-keying building”.46 The policy says nothing about the design of UConn’s cylinders or whether they are susceptible to this attack. What the attack adds is a route to the master that involves no lost key at all.
How the measures compare
A measure that raises the attacker’s cost is easily mistaken for one that removes the weakness.
| Effect | Measures | Limits |
|---|---|---|
| Remove the exposure for those doors | No master keying; single-keyed doors with keys in a cabinet | Loses master-key convenience |
| Remove the per-position feedback | Master ring and bicentric cylinders; positional systems; electronic access decisions | Each has other weaknesses; the sources date the availability of specific designs (Blaze 2003, Lynk 2022, Howard 2021) |
| Reduce what a derived master opens | Separate master systems; sensitive doors taken off the master; avoiding sectional masters | Cylinders kept within a retained split-pin system stay exposed |
| Raise the attacker’s cost or ambiguity | Restricted or patented keyways where blank control holds; sidebars that accept the change coding throughout; false cuts; trap pinning | Blanks have proved obtainable for some products; false cuts and traps are proposals with trade-offs |
| Report tested properties | Ratings such as UL 437 and A156.30 | Evidence of what was tested; no public test for this attack |
| Help detection and recovery | Interchangeable cores (faster core replacement); rekeying the affected domain; audit trails on electronic cylinders | Do not prevent derivation; conventional mechanical locks record nothing |
What a building operator should do differently
Decide whether the master key is worth its reach. Blaze’s advice was that owners “should consider carefully whether the security risks of mastering outweigh its convenience benefits.”15 The effective access scope of a master in a conventional split-pin system includes anyone with a key and its lock in that domain.
Ask the questions that set the risk. Which doors share a master with which, and how far does the top master reach? Do change keys and master keys share the same shear line, or does the master have its own mechanism? Is the system TPP or RC, how many stacks carry master pins, and are there sectional keyways whose master blank fits several sections? Where are the incidental masters, and which common doors are cross keyed or loaded with master wafers?1108 Whether complete keying records exist, and who holds them, is itself one of the questions; A156.28 treats record-keeping as part of key management.44
Change the planning assumption. For a conventional split-pin master system of the kind Blaze studied, assume that anyone who has held or examined a key to it and had access to the matching lock may hold that system’s master. Blaze’s fact sheet makes the same point: “any individual who has ever been given access to any key has the potential to carry out the attack.”6 That covers former employees, contractors and tenants who returned their keys.
Take high-value doors off the master system. Server rooms, pharmacies, evidence rooms, cash rooms and records stores should not be reachable from a key that every office holds. Key them individually, keep their keys in a controlled cabinet or an electromechanical system with an audit trail, and accept the inconvenience.612
Shrink each master system. Separate master systems by building, function or tenant, so that one derived master opens a floor, not a campus.6 Avoid sectional schemes whose master blank fits every keyway in the estate.17
Treat configuration changes as trade-offs. Fewer master pins, more constants and dedicated keys in place of cross keying reduce incidental keys and interchange.12 They do not take the system out of the vulnerable family. For new hardware on sensitive doors, ask whether a cylinder that gives the master a separate shear line, or an electronic alternative, is available for the door type.3531
Read ratings for what they test. A high-security listing is evidence of the properties tested, including key blank control under A156.30.43 It is not evidence that a master system resists its own key holders. Value a restricted or patented keyway for the blank control it actually delivers, and check when its patent expires.395
Decide on rekeying as a risk question. Interchangeable cores make it possible to swap cores without changing hardware.8 In our judgment, whether to rekey a master system periodically, for example after staff turnover or a contract change, depends on what the system protects and what rekeying costs at that site; the sources here give no general schedule. In our judgment, a full rekey of the affected master domain belongs in the response to any incident in which an insider with a key is suspected.
Use electronics where records matter. A conventional mechanical lock keeps no record of who used it or how often. Where detecting misuse matters as much as resisting it, use credentials that can expire or be revoked and cylinders that store events, remember that revocation takes effect only as the system’s validity rules allow, and that mechanical cylinders in a mixed system keep their mechanical keying.45
Conclusion
Blaze’s 2003 paper showed that conventional split-pin master systems, in which change and master keys share one shear line and pin positions are mastered independently, expose the master bitting to someone with a change key and access to its lock. Because each position is accepted on its own, the lock’s intended decision is informative about one position at a time, and the work grows with a sum of per-position choices instead of their product. What a derived master opens is the master domain itself, not doors keyed outside it. Some locksmiths knew versions of the method and taught it as a lost-key service; Tobias’s view in 2003 was that security managers did not know. Cylinders that give the master its own shear line, and positional systems, avoid this particular exposure. Restricted keyways help only as far as blank control holds, and ratings report what was tested. The operator’s decision is whether a master key’s convenience justifies its effective reach: if it does, keep the domain small and sensitive doors out of it; if it does not, drop master keying for those doors.
Footnotes
- Matt Blaze, “Cryptology and Physical Security: Rights Amplification in Master-Keyed Mechanical Locks,” AT&T Labs – Research, preprint dated 15 September 2002, revised 2 March 2003, §§1–3.1 (pin tumbler and master-keying background, TPP and RC, prior decoding methods). https://www.mattblaze.org/papers/mk.pdf (opens in a new tab) ↩1 ↩2 ↩3 ↩4 ↩5 ↩6 ↩7 ↩8 ↩9 ↩10 ↩11 ↩12 ↩13 ↩14
- Matt Blaze, “Rights Amplification in Master-Keyed Mechanical Locks,” IEEE Security & Privacy 1(2), pp. 24–32, 2003. DOI: https://doi.org/10.1109/MSECP.2003.1193208 (opens in a new tab); bibliographic record, Georgetown SecLab: https://seclab.cs.georgetown.edu/bibliography/DBLP_journals/ieeesp/Blaze03.html (opens in a new tab) ↩
- Blaze, “Cryptology and Physical Security,” §3 introduction and §3.2 (the adaptive oracle attack, notation and worst-case counts, footnote 2 on prior discovery). https://www.mattblaze.org/papers/mk.pdf (opens in a new tab) ↩1 ↩2 ↩3 ↩4 ↩5 ↩6 ↩7 ↩8 ↩9 ↩10 ↩11 ↩12
- Matt Blaze, “Notes on Picking Pin Tumbler Locks,” University of Pennsylvania, 7 November 2003, revised 21 November 2016. https://www.mattblaze.org/papers/notes/picking/ (opens in a new tab) ↩
- Blaze, “Cryptology and Physical Security,” §4 “Countermeasures” and footnotes 3–4 (master rings, positional schemes, restricted blanks, false cuts, patent-based key control). https://www.mattblaze.org/papers/mk.pdf (opens in a new tab) ↩1 ↩2 ↩3 ↩4 ↩5 ↩6 ↩7 ↩8 ↩9 ↩10 ↩11
- Matt Blaze, “Master-Keyed Lock Vulnerability” (fact sheet), AT&T Labs – Research, 16 January 2003, revised 27 January 2003. https://mattblaze.org/masterkey.html (opens in a new tab) ↩1 ↩2 ↩3 ↩4 ↩5 ↩6 ↩7 ↩8 ↩9
- Allegion, Schlage Everest Full Size Cylinder Service Manual, document 008484, Rev. 03/14 (printed imprint; the file name reads 108484), “Master keying” and key specifications pages (MACS 7, ten root depths, two-step progression, 4,096 theoretical changes per keyway). https://commercial.schlage.com/content/dam/allegion-us-2/web-files/schlage/technical-documents/Schlage_Everest_Full_Size_Cylinder_Service_Manual_108484.pdf (opens in a new tab) ↩1 ↩2 ↩3
- Lock Industry Standards and Training (LIST) Council terminology, reproduced in Master Lock, Technical Manual 7000-0031, pp. 30–38; entries cited: control key, control shear line, cross keying, incidental master key, interchangeable core, key bitting array, key interchange, master pin, maximum adjacent cut specification, progression, rotating constant method, total position progression. https://cdn.masterlock.com/masterlock/resources/documents/pdf/7000-0031_Technical_Manual_pg_30_38.pdf (opens in a new tab) ↩1 ↩2 ↩3 ↩4 ↩5 ↩6 ↩7 ↩8 ↩9 ↩10 ↩11
- Will Christensen, “Positional Master Keying Explained,” Locksmith Ledger, 19 December 2022 (interview with William M. Lynk). https://locksmithledger.com/21285217 (opens in a new tab) ↩1 ↩2 ↩3
- Tom Gillespie, “Thoughts On Master Keying,” Locksmith Ledger, 1 October 2010. https://www.locksmithledger.com/keys-tools/article/10227919/thoughts-on-master-keying (opens in a new tab) ↩1 ↩2 ↩3 ↩4 ↩5 ↩6 ↩7
- Gale Johnson, “Mastering The Art Of Masterkeying,” Locksmith Ledger, 2 January 2017. https://locksmithledger.com/locks/article/12284967/mastering-the-art-of-masterkeying (opens in a new tab) ↩1 ↩2
- “Master Keying with Medeco,” Locksmith Ledger, 4 January 2016. https://locksmithledger.com/locks/article/12144614/master-keying-with-medeco (opens in a new tab) ↩1 ↩2 ↩3 ↩4 ↩5
- Benjamin Laxton, Kai Wang and Stefan Savage, “Reconsidering Physical Key Secrecy: Teleduplication via Optical Decoding,” ACM CCS 2008, Alexandria, Virginia, 27–31 October 2008, §2. https://vision.ucsd.edu/sites/default/files/publications/pdfs/Reconsidering%20Physical%20Key%20Secrecy%20Teleduplication%20via%20Optical%20Decoding.pdf (opens in a new tab) ↩
- John Schwartz, “Master Key Copying Revealed,” The New York Times, 23 January 2003, as reposted in full to the InfoSec News mailing list the same day. https://seclists.org/isn/2003/Jan/109 (opens in a new tab) ↩1 ↩2 ↩3 ↩4 ↩5 ↩6 ↩7 ↩8 ↩9 ↩10
- Blaze, “Cryptology and Physical Security,” §5 “Conclusions and Lessons Learned” (undiscovered compromise, rekeying, convenience trade-off, the key-bit analogy, Tenex, related-key attacks and traitor tracing). https://www.mattblaze.org/papers/mk.pdf (opens in a new tab) ↩1 ↩2 ↩3 ↩4 ↩5 ↩6 ↩7
- Blaze, “Cryptology and Physical Security,” §3.3 “Experimental Results” (systems tested, materials, outcomes and caveats). https://www.mattblaze.org/papers/mk.pdf (opens in a new tab) ↩1 ↩2 ↩3 ↩4 ↩5 ↩6 ↩7
- Blaze, “Cryptology and Physical Security,” §3.2.3 “Practical Considerations” (MACS, non-standard depths, multi-level systems, sectional mastering, high-security designs). https://www.mattblaze.org/papers/mk.pdf (opens in a new tab) ↩1 ↩2 ↩3 ↩4
- Butler W. Lampson, “Hints for Computer System Design,” 1983 (ACM Operating Systems Review 15(5), October 1983), §2.1, Tenex
CONNECTexample; course copy, Princeton COS 518. https://www.cs.princeton.edu/courses/archive/fall15/cos518/papers/hints-design.pdf (opens in a new tab) ↩1 ↩2 ↩3 - John Black and Hector Urtubia, “Side-Channel Attacks on Symmetric Encryption Schemes: The Case for Authenticated Encryption,” 11th USENIX Security Symposium, 2002, §§1 and 3. https://www.usenix.org/legacy/event/sec02/full_papers/black/black_html/index.html (opens in a new tab) ↩1 ↩2 ↩3
- Matt Blaze, “Safecracking for the computer scientist,” University of Pennsylvania, draft of 7 December 2004, revised 21 December 2004. https://www.mattblaze.org/papers/safelocks.pdf (opens in a new tab) ↩1 ↩2 ↩3
- Matt Blaze, “Cryptology and Physical Security: Rights Amplification in Master-Keyed Mechanical Locks,” Cryptology ePrint Archive, Paper 2002/160, history entry “2002-10-23: received”. https://eprint.iacr.org/2002/160 (opens in a new tab) ↩
- Ed Felten, “Most Door Locks Insecure,” CITP Blog, Princeton University, 23 January 2003. https://blog.citp.princeton.edu/?p=267 (opens in a new tab) ↩
- Matt Blaze, “Keep it secret, stupid!”, originally posted to comp.risks and Interesting-People, 26 January 2003. https://www.mattblaze.org/papers/kiss.html (opens in a new tab) ↩1 ↩2 ↩3 ↩4 ↩5
- Bruce Schneier, “Locks and Full Disclosure,” IEEE Security & Privacy, March/April 2003. https://www.schneier.com/essays/archives/2003/03/locks_and_full_discl.html (opens in a new tab) ↩
- Matt Blaze, “The second sincerest form of flattery,” originally posted to Interesting-People, 19 January 2005. https://www.mattblaze.org/papers/flattery.html (opens in a new tab) ↩
- Matt Blaze, “On the discussion of security vulnerabilities,” January 2003, revised January 2005; quotes Hobbs and the Lentz and Kenton excerpt. https://www.mattblaze.org/hobbs.html (opens in a new tab) ↩1 ↩2 ↩3
- Charles Tomlinson (ed.), Rudimentary Treatise on the Construction of Locks, London: John Weale, first published 1853, pp. 2–3 (“On Locks and Lock-Literature”). Internet Archive page images of the Getty Research Institute copy, which also carries an advertisement by Robert Mallet dated April 1868. https://archive.org/details/rudimentarytreat00hobb/page/n15/mode/2up (opens in a new tab) ↩1 ↩2
- Donald Eastlake 3rd, “Re: [IP] Master Key Copying Revealed (Matt Blaze of ATT Labs),” forwarded to the Cryptography mailing list, 23 January 2003. https://www.metzdowd.com/pipermail/cryptography/2003-January/003808.html (opens in a new tab) ↩
- Bram Cohen, “Keep it secret, stupid!” (reply), Cryptography mailing list, 26 January 2003. https://www.metzdowd.com/pipermail/cryptography/2003-January/003846.html (opens in a new tab) ↩1 ↩2
- Matt Blaze, “Keep it secret, stupid!” (reply to Bram Cohen), Cryptography mailing list, 26 January 2003. https://www.metzdowd.com/pipermail/cryptography/2003-January/003844.html (opens in a new tab) ↩
- Richard Howard, “Master Ring Cylinders,” Keynotes (Associated Locksmiths of America), May 2021, pp. 34–45 (history and dimensions p. 34; picking p. 38; Bicentric comparison p. 39). https://absupply.net/pdf/Certificates/Richard-Howard-ALO-Key-05-21-Feature-MasterRingCylinders.pdf (opens in a new tab) ↩1 ↩2 ↩3 ↩4 ↩5 ↩6
- Edward J. O’Keefe, “Lock,” US Patent 414,720, issued 12 November 1889 (assignment to P. F. Corbin per Howard). https://patents.google.com/patent/US414720A/en (opens in a new tab) ↩
- SARGENT, “Keso F1” product page, accessed 25 November 2026. https://www.sargentlock.com/en/commercial-locks-products/key-systems/product-details-keso-f1.aehpdp-keso-f1-aeh_sargent_219713 (opens in a new tab) ↩
- Len Sassaman, “Keep it secret, stupid!” (reply), Cryptography mailing list, 26 January 2003. https://www.metzdowd.com/pipermail/cryptography/2003-January/003850.html (opens in a new tab) ↩
- Matt Blaze, “Keep it secret, stupid!” (reply to Len Sassaman), Cryptography mailing list, 27 January 2003. https://www.metzdowd.com/pipermail/cryptography/2003-January/003854.html (opens in a new tab) ↩1 ↩2 ↩3 ↩4
- Ben Burgess, Eric Wustrow and J. Alex Halderman, “Replication Prohibited: Attacking Restricted Keyways with 3D-Printing,” 9th USENIX Workshop on Offensive Technologies (WOOT 15), 2015, §§2.3, 3, 6.1 and 6.2. https://files.usenix.org/s3fs-public/cdn/woot15-paper-burgess.pdf (opens in a new tab) ↩1 ↩2
- David Lawrence, Robert Johnson and Eric Van Albert, “Key Decoding and Duplication Attacks for the Schlage Primus High-Security Lock,” DEF CON 21, 2013 (InfoCon listing with speakers’ abstract). https://infocondb.org/con/def-con/def-con-21/key-decoding-and-duplication-attacks-for-the-schlage-primus-high-security-lock (opens in a new tab) ↩
- DEF CON, “DEF CON 21 Speakers,” speaker listing for “Key Decoding and Duplication Attacks for the Schlage Primus High-Security Lock.” https://defcon.org/html/defcon-21/dc-21-speakers.html#Lawrence (opens in a new tab) ↩
- “Schlage High Security: Upgrading Primus to Primus XP,” Locksmith Ledger, 1 February 2008. https://www.locksmithledger.com/locks/article/10229534/schlage-high-security-upgrading-primus-to-primus-xp (opens in a new tab) ↩1 ↩2 ↩3
- Roy C. Spain, Roy N. Oliver, Elvis C. Flora and Paul A. Powell, “Cylinder lock,” US Patent 3,499,302, filed 1 March 1967, issued 10 March 1970. https://patents.google.com/patent/US3499302A/en (opens in a new tab) ↩
- UL Standards & Engagement, “UL 437: Key Locks,” catalogue entry with scope, Edition 8, last revised 31 January 2023. https://www.shopulstandards.com/ProductDetail.aspx?productId=UL437 (opens in a new tab) ↩
- “UL 437,” Lockwiki (third-party summary of the Underwriters Laboratories standard for key locks), last edited 20 August 2009. https://lockwiki.com/index.php/UL_437 (opens in a new tab) ↩
- Builders Hardware Manufacturers Association, “A156.30 – 2025 High Security Cylinders,” Hardware Highlights summary. https://buildershardware.com/ANSI-BHMA-Standards/Hardware-Highlights/A15630-2025-High-Security-Cylinders (opens in a new tab) ↩1 ↩2
- Builders Hardware Manufacturers Association, “A156.28 – 2023 Recommended Practices For Mechanical Keying Systems,” Hardware Highlights summary. https://buildershardware.com/ANSI-BHMA-Standards/Hardware-Highlights/A15628-2023-Recommended-Practices-For-Mechanical-Keying-Systems (opens in a new tab) ↩1 ↩2
- ABLOY, PROTEC2 CLIQ Technical Guide (technical brochure 8807193, 08/2022), sections “Cylinder function”, “How system works?”, remote programming, online opening, key revalidation and audit trails. https://www.abloy.com/gb/en/documents/2026/protec2-cliq/PROTEC2%20CLIQ%20Technical%20Guide.pdf (opens in a new tab) ↩1 ↩2 ↩3 ↩4 ↩5 ↩6
- University of Connecticut Facilities Operations, “Key Policies,” revision posted September 2023 (date from the file’s path and name), sections E and G. https://fo.media.uconn.edu/wp-content/uploads/sites/2782/2023/09/Key-Policies-Univ-of-CT-Final-REVISION-9.2023.pdf (opens in a new tab) ↩