Abstract

What does a buyer learn from “Grade 1”, “UL 437 listed” or an ANSI/BHMA A156.30 level? Each label answers a different question. ANSI/BHMA grades for locks and cylinders mostly measure durability, operation and strength: a Grade 1 bored lock must survive one million operating cycles and meet torque and impact requirements. UL 437 measures resistance to defined attacks under laboratory conditions; historical summaries from 2007 and 2009 give 10 minutes for picking and impressioning door locks and cylinders and 5 minutes for forcing methods under earlier editions. A156.30 rates high-security cylinders separately on key control, destructive attack and surreptitious attack, and each category’s result is set by its weakest feature. Certification programmes list products or product families on the strength of laboratory evaluation; the installed door, frame and strike need their own assessment. Bumping, the reported Medeco deadbolt bypass, keys decoded from photographs and 3D-printed blanks show why the scope of the applicable tests matters. Specifiers should treat a rating as a floor for one product, verify the exact model, applicable edition and scope with the certifier, and assess the rest of the opening themselves.

Three labels, three questions

A door hardware schedule might call for a “Grade 1 mortise lock with a UL 437 listed, A156.30 high-security cylinder”. The three clauses are three separate claims from three test regimes, and each one leaves out something the others cover.

The Builders Hardware Manufacturers Association (BHMA) writes the ANSI/BHMA A156 series. Its grades (1, 2 and 3, with 1 the highest) are “defined by progressive levels of performance benchmarks” in each standard.1 Most of those benchmarks concern how long the hardware lasts, how it operates and how much force it withstands. UL 437, the Standard for Key Locks, published by UL Standards & Engagement, asks a different question: how long does a lock resist defined attacks under defined test conditions? ANSI/BHMA A156.30 asks a third: how hard is it to get an unauthorised key, to open the cylinder covertly, or to defeat it by force?

The distinction matters because the threats that matter in practice can fall between them.

ANSI/BHMA grades: durability, operation and strength

What the standards cover

Three BHMA standards matter most for keyed door locks. ANSI/BHMA A156.2 covers bored and preassembled locks and latches (the cylindrical locksets common on commercial doors); BHMA’s summary of the 2022 edition says it “includes cycle tests, strength tests, operational tests, material evaluation tests, finish tests, and dimensional criteria.”2 ANSI/BHMA A156.13 covers mortise locks and latches; its 2022 edition “includes operational tests, strength tests, security tests, cycle tests, finish tests and dimensional criteria.”3 ANSI/BHMA A156.5, Cylinders and Input Devices for Locks, covers the cylinder itself and, in its 2020 edition, electrical input devices such as card readers, keypads and mechatronic cylinders.4

BHMA publishes a short “Hardware Highlights” summary of each standard. The full texts are sold, so the numbers below are the ones BHMA or manufacturers have published. Clause numbers and the complete test lists are in the paid documents.

Cycles

The cycle test separates the grades most visibly. Allegion’s 2013 specification guide calls it “the key differentiator” and quotes one of its specification managers saying that architects and builders “look to the cycle test to get the best picture of real-world application.”5 BHMA’s summary of A156.2 says that “Grade 1 locks, for example, must pass a rigorous test through one million cycles of opening and closing with a 10 pound axial load applied.”2 The A156.13 summary gives the same one million cycles for Grade 1 mortise locks.3

BHMA’s summaries do not give the Grade 2 and Grade 3 figures. Allegion’s guide, dated December 2013, gives these historical cycle counts:5

StandardGrade 1Grade 2Grade 3
Bored locks (A156.2)1,000,000400,000200,000
Mortise locks (A156.13)1,000,000800,000800,000

That table predates the 2022 editions of A156.2 and A156.13, and BHMA’s current summaries confirm only the Grade 1 figures. Anyone who needs the Grade 2 or 3 count for a contract should take it from the edition the contract cites.

Cylinders are graded separately under A156.5. BHMA’s summary says that “Grade 1 cylinders, for example, must pass a rigorous test through 40,000 cycles and still operate at reasonable forces,” and that inserting or removing the key must take no more than 3 pounds of force.4

Operation, strength and “security” tests

The grades also cover operation. The A156.2 and A156.13 summaries measure “the force to retract the latch and force to close the door”, and give a maximum of 28 in-lbf to operate a lever.23 Separately, each lock standard contains strength tests that BHMA’s summaries call security tests. BHMA describes seven such tests for A156.2, “including a 1,200 in-lbf locked lever torque and two directions of impact,” and fifteen for A156.13, including the same torque and impacts.23 Allegion’s guide lists the kinds of test involved: tension loading, impact, deadbolt torque, bolt strength, a warped-door test, vertical load and finish.5 The A156.5 summary describes “an array of strength tests” of the cylinder’s resistance to attempted entry, and adds ESD, over-voltage and water tests for electrical input devices.4

The strength tests are tests of force: a fixture applies a measured torque or impact, and the lock either holds or does not. They say little about a person with picks, a decoder or a copied key. The 2014 edition of A156.5 said as much in its scope. BHMA has posted that scope text, which describes the standard’s intent as “fair, uniform and repeatable testing”, and continues:6

We recognize that any cylinder can be compromised or destroyed by excessive force or extended time or by the use of custom designed tools or techniques.

The same scope adds that “No lock can provide complete security by itself. Locks may be defeated by forcible or technical means, or evaded by entry elsewhere on the property,” and directs readers who need “pick resistance and other higher security protections” to UL 437 or A156.30.6 A plain grade, in other words, is not a pick-resistance rating.

What a grade does and does not compare

A grade is relative to its own standard. Allegion’s guide makes the point directly: two product categories “may share Grade 1 status, but that doesn’t mean they were evaluated by the same criteria,” and “A mortise lock and a cylindrical lock are not judged by the same standards, nor should they be.”5 A Grade 1 bored lock and a Grade 1 mortise lock passed different test lists, and a Grade 1 cylinder passed a third.

The grades also attach to assemblies in a particular way. The 2014 edition of A156.30, in text BHMA has posted, says that “Assemblies take the grade of the lowest graded component,” and that “A lockset mated with a cylinder having no Grade listing, even though the cylinder has a high security level is considered ungraded.”7 Under the 2014 text, a Grade 1 lockset fitted with an ungraded cylinder is ungraded.

A156.5 does offer an optional drill-and-pick designation tied to UL 437. In a committee review copy of the 2014 edition, section 6.6.6 reads: “Cylinders meeting all the drilling and picking requirements of UL 437-2013 shall be designated with the applicable type number including the suffix A. The cylinder shall also meet Grade 1 requirements of this standard. Cylinders which are listed to UL 437 do not need to be retested for drill and pick resistance.”8 The 2020 summary’s example “E09231AL” “refers to a Grade 1 cylinder used in bored locks only and is rated to be drill and pick resistant, per UL 437.”4 The suffix therefore records that a cylinder met UL 437’s drilling and picking requirements, which is not the same as holding a UL listing; a listing has to be checked with UL.

UL 437: timed attacks under defined conditions

Scope and edition

UL 437 is in its eighth edition, published 15 May 2013. Its scope covers “a) Cabinet locking cylinders, b) Door locks, c) Locking cylinders, d) Security container key locks, Type 1 and Type 2, and e) Two-key locks.” The publisher’s current record shows a last revision and ANSI approval on 31 January 2023, and explains that revision as a reaffirmation: “No technical changes have been made.”9

UL’s standards catalogue, as archived in 2019, shows the shape of the standard. Construction requirements include a section on “Key Changes” and one on security container locks. The performance section contains an endurance test, a salt-spray corrosion test, polymer tests, and Section 11, “Attack Resistance Tests,” with subsections for tools, test samples, test installation, “Test applicability and time”, and then the individual attacks: picking, “Lock bumping test” (marked “effective November 16, 2015”), impression, forcing, drilling, sawing, prying, pulling and driving.10 The title “Test applicability” matters: not every test applies to every class of lock.

The test times

The text of UL 437 is sold, and UL’s catalogue pages do not give the test times. The figures in circulation come from secondary summaries. One is a slide from Marc Weber Tobias, an attorney and lock researcher, presented at Hack in the Box in Kuala Lumpur in September 2007, which lists “UL-437 Attack Resistance (Door locks and Cylinders)” as:11

AttackTime (door locks and cylinders, as summarised in 2007)
Picking10 minutes
Impressioning10 minutes
Forcing5 minutes
Drilling5 minutes
Sawing5 minutes
Prying5 minutes
Pulling5 minutes
Driving5 minutes

LockWiki’s UL 437 page, last edited in 2009, gives the same door-lock times, though it names the last test “punching” where Tobias and UL’s table of contents say driving.12 Both sources predate the eighth edition of May 2013 and its bumping test, so the figures are historical secondary evidence, not a statement of current requirements. Other lock classes have their own times and their own lists of applicable tests, which the public summaries do not reliably distinguish; a specifier buying a container lock or two-key lock should read the standard. The mechanics of picking, and why manufacturing tolerances decide how long it takes, are covered in How pin tumbler locks are opened.

A time in a test standard is a laboratory measure. It says how long a cylinder resisted a tester working under the standard’s rules, on a sample, in a test installation. It does not tell an owner how long a door will hold.

What UL 437 says about keys

UL 437 requires a minimum number of key changes; its table of contents has a section with that title.10 LockWiki says door locks and cylinders need at least 1,000 differs.12 Key changes measure the size of the keyspace. Control over who can obtain blanks and have keys cut is a separate matter. Tobias’s slides, which predate the eighth edition, stated: “UL 437: No key control criteria.”11 The public table of contents of the eighth edition shows a key-changes section but no section on blank or duplication control.10

A UL 437 certification covers the requirements applicable to the certified product. The Edition 8 catalogue dates §11.7, the lock bumping test, to 16 November 2015.10 On the public evidence it is not a statement about whether a key can be copied.

ANSI/BHMA A156.30: three categories and the weakest feature

Editions

A156.30 is BHMA’s high-security cylinder standard. The text of the adopted 2014 edition that BHMA posted in 2019 identifies it as a “Revision of ANSI/BHMA A156.30-2007,” approved 15 August 2014.7 A committee review copy of the same edition, which BHMA also hosts, is headed “Revision of ANSI/BHMA A156.30-2010”, and the 2014 A156.5 scope also mentions an A156.30-2010;136 neither mention shows that a 2010 edition was published. A 2022 directory certificate cites a listing to the 2020 edition,14 and BHMA’s current summary covers A156.30-2025.15 The full 2025 tables are not public. The figures below come from BHMA’s summaries and from the 2014 committee copy, and should be checked against the edition a contract cites.

The 2025 standard “includes security performance based requirements for both mechanical and electrified high security cylinders,” and defines a high security cylinder to include “mechanical lock cylinders, electromechanical cylinders, and the electronic lock sub assemblies that are analogous to the cylinder assemblies.”15 The adopted 2014 text said that cylinders include “their keys or electronic credentials; their detainers (mechanical pins, levers, discs) or electronic control device; and their cylinder tailpiece or cam or electronic output port,” and that its tests “are performed under laboratory conditions. In actual usage, results vary because of installation, maintenance and environmental conditions.”7

Levels in A156.30 are separate from grades. The 2014 text says: “Levels indicate special security features and are separate from Grades.” To carry a grade, a high-security cylinder must also be tested to A156.5, and electrified products to A156.25.7

Key control

A156.30 has a category the other two regimes lack. BHMA’s 2025 summary says key control “is intended to provide security by limiting the availability of unauthorized keys or unauthorized electronic credentials that would operate the locks,” with attributes including key blank control, restrictions on cylinder marking, and, for electronic products, audit trail and time-zoning capability.15 The last two are management functions, not resistance tests.

The 2014 committee copy shows how the mechanical blank-control levels were written then. At Level C, “Blanks are not available from a second source, only from the manufacturer,” and manufacturers maintain internal procedures to protect keys; Level B is “Level C plus Blanks are protected by law”; Level A is “Level B plus Factory cut keys are only provided by the manufacturer only after authorization.”13 Legal protection of blanks generally means patents; Burgess and colleagues note that “Often the key blank designs themselves are patented, further discouraging distribution or manufacture by even skilled machinists.”16

Destructive and surreptitious attack

The destructive tests, according to the 2025 summary, include a static pull test on the cylinder plug, an impact pull test, applied torque and a drill resistance test with a total test time of 5 minutes for one level and ten minutes for the top level. For mechanical cylinders the summary’s pass criterion is that “the lock driving element of the cylinders shall not rotate without the correct key.”15 The 2014 committee copy uses two clocks: no drill test at Level C; at Level B a 3-minute net drilling time within a 5-minute total test time; at Level A a 5-minute net drilling time within a 10-minute total. For electronic devices it defines failure separately, as allowing access to the output ports or output devices.13 The 2025 summary reports the same total times but assigns five minutes to Level B and labels the ten-minute tier Level C, where the 2014 committee copy labels it Level A.15

The surreptitious category, in the 2025 summary, covers a minimum number of key changes, limits on key bitting steps, mechanical pick resistance tested by decoding or picking, electrical attacks (over-voltage, electrostatic discharge, magnets and conductive liquids), and a mechanical tolerance test of up to 100,000 cycles for the top level.15 The summary does not mention bumping or impressioning by name. In the 2014 committee copy, the tolerance test required one cycle at Level C, 40,000 at Level B and 100,000 at Level A.13

The weakest-feature rule and the rating code

Each A156.30 category is rated by its weakest feature. BHMA’s summary states: “To declare level ‘A’, all features within the category must achieve level ‘A’. To declare level ‘B’, all features within the category must achieve at least a ‘B’; similar for Category ‘C’.”15 On that rule, a cylinder whose pick resistance meets the top level but whose number of key changes meets only the bottom one is rated at the bottom level for surreptitious attack.

The code itself is explained in the 2014 committee copy. The first character, M, signifies “BHMA Section M for High Security Cylinders”; the second is the grade under A156.5 or A156.25 (0 for none, or 1 to 3); the third, fourth and fifth are the key control, destructive and surreptitious levels; and a suffix E or M denotes an electrical or mechanical cylinder.13 BHMA’s example, “M1ACAE is a grade 1 electrical cylinder meeting levels A, C, and A respectively,” appears in both the 2014 copy and the 2025 summary.15 A dated entry shows how to read a record: a BHMA certificate printed on 7 March 2022 for a BEST high-security cylinder lists the code “M1AAAM”, with key control, destructive test and surreptitious entry resistance each at “Level A”, standard year 2020.14

Which letter is highest?

BHMA’s summaries contradict themselves on a point that matters. The 2020 and 2025 Hardware Highlights both call C the highest level, for key control (“level ‘C’ being the highest”), for drilling and for the tolerance test.1715 Yet both pages also say that “The minimum listing requires at least a ‘C’ in each category,” which is hard to reconcile with C being the top level. In the historical material the order is clear: the 2014 committee copy builds Level B as “Level C plus” and Level A as “Level B plus”, with thresholds rising from C to A,13 and Tobias’s account of the edition current in 2007 also puts A at the top.11 The 2022 BEST certificate shows that an AAA listing exists, but not how the levels rank.14

The summaries repeat an internal inconsistency, so they cannot settle the ranking in the adopted 2025 edition; that needs the 2025 normative tables or a written clarification from BHMA. A specifier who writes “A156.30 Level A” or “Level C” into a contract without naming the edition and quoting that edition’s definition risks asking for the opposite of what they intend.

The three regimes side by side

RegimeANSI/BHMA A156.2, A156.13, A156.5 gradesUL 437ANSI/BHMA A156.30 levels
Main questionDoes the hardware last, operate correctly and resist measured force?How long does it resist defined attacks under defined conditions?Are keys controlled, and how does it resist covert and forced attack?
What is testedCycles, operating forces, torque, impact, finish; A156.5 adds cylinder strength and electrical tests, and an optional suffix A for meeting UL 437 drill and pick requirementsAttack tests applicable to the lock class (picking, impressioning, bumping from 2015, forcing, drilling, sawing, prying, pulling, driving); key changes; enduranceKey control, destructive attack (pull, impact pull, torque, drilling), surreptitious attack (picking or decoding, electrical attacks, key changes, tolerance cycling)
Published quantitiesGrade 1: 1,000,000 cycles for bored and mortise locks; 40,000 for cylinders; 1,200 in-lbf locked lever torqueDoor locks and cylinders, historical summaries (2007, 2009): 10 minutes picking and impressioning, 5 minutes for forcing methods2025 summary: drilling 5 and 10 minutes total test time for two levels, tolerance test up to 100,000 cycles; letter ranking unresolved
Key controlNot a graded category in BHMA’s summariesMinimum key changes; no blank-control section in the public contentsA graded category
Who certifiesBHMA programme; testing by designated labs (Intertek, UL)UL certification with factory follow-upBHMA programme; same labs
What is certifiedListed products or families, from representative lab testingCertified products, from lab evaluationListed cylinders, rated at the weakest feature in each category
Where to checkBHMA Certified Products DirectoryUL Product iQBHMA Certified Products Directory

Testing, certification and the word “meets”

BHMA certification

BHMA runs a voluntary certification programme. Manufacturers “voluntarily submit a hardware product to independent laboratory testing to confirm that the product fully meets the criteria of its ANSI/BHMA standard,” and “In-factory audits are conducted periodically to assure product compliance with the standard. Products unable to pass the auditing process face loss of certification.” Membership of BHMA is not required.18

The programme’s Operational Manual (January 2024) sets out who tests. “The authority for the selection of test laboratories is vested in the BHMA,” and designated labs “shall be independent and nationally recognized.” For A156.2, A156.5, A156.13 and A156.30 alike, Schedule 1 names the test labs as Intertek and UL and requires that “Each product shall be tested once every four years,” where a product is defined as “A family (series) of similar hardware having the same essential design where random selection and testing of any one would fairly represent the group.” Re-certification samples are chosen by one of three methods: selected by the lab’s representative, selected by a participant employee authorised by the lab, or “Obtained randomly through a distributor.” New and re-certification testing must be to the latest edition, though a listing to the previous edition is allowed “up to one year following the published ANSI approval date.”19

The manual also allows anyone to challenge a certified product, under conditions. The complainant must first have “tested the product or finish type according to the Standard and submitted a copy of the results” to BHMA and the lab; only then, “if, in the sole judgment of the Laboratory, there appears to be reasonable grounds for the complaint,” does the lab sample and test the product.19

Two details matter for buyers. First, a manufacturer may use other labs: “Alternate labs may also be used by the Licensee for informational purposes,” and it is the designated lab’s decision whether to accept their reports.19 A manufacturer’s own or alternate-lab testing can support a claim that a product “meets” a grade without that product ever entering the certification programme. Second, testing is spread across product families over a four-year cycle, so a given model may not have been sampled recently. Between tests, the factory audit is what stands behind the listing.

The directory and the soft claim

BHMA’s Certified Products Directory (CPD) provides “an up-to-date listing of all products that have been certified to ANSI/BHMA Standards,” can be searched by standard or by brand, and states that compliance “is based upon a series of tests verified by independent, third-party laboratories” and that listed products “undergo periodic recertification.”20 Under the Operational Manual, a licensee’s directory submissions must include the year of the standard’s edition, and an originating manufacturer whose products are resold under another name may ask that its own listings not be published.19 Certificates downloaded from it, such as the BEST example above, carry the model, series, function, standard year and level code, and state that “Only products listed in the BHMA Online Certified Product Directory are allowed to display the BHMA Certified Mark and assert compliance with this Program.”14

BHMA’s labelling page describes the failure mode buyers should expect. It says the most frequent reports of misuse are cases where certified branding “is being falsely displayed, or vague language and soft phrases are used to falsely imply that a product is BHMA Certified without saying it directly,” and advises that “products legitimately certified by BHMA will always be listed on BHMA’s Certified Products Directory.”21 A catalogue line such as “meets ANSI Grade 1” may be true, and the manufacturer may hold test reports to support it. Without a directory listing for the exact model, though, BHMA certification is unverified, and the next step is to ask BHMA.

UL certification and follow-up

UL certification works differently. The manufacturer’s product is evaluated against the standard, and after certification UL’s Follow-Up Services programme “begins at the locations you identify as authorized to manufacture your product,” with “factory inspections and audits at locations where UL Certified products are manufactured and the UL Mark applied,” designed “to confirm that a manufacturer’s UL Certified product continues to comply with the original certification requirements.”22 Follow-up is about production conformity: that the product being made is the one that was evaluated. UL’s Product iQ database is the tool UL describes for “verifying the UL certification of a product or component.”23 If a record does not show which edition or revision a product was evaluated to, that has to come from the certification documentation or from UL.

Where laboratory attacks and real threats part company

Every rating above defines its attacker: the tests, the tools and the times are set when the edition is drafted. That is what makes the tests repeatable and the results comparable. It is also why they cannot measure resistance to an attack that the drafters had not written down.

Bumping

Bump keys were old trade knowledge; Wired noted in 2007 that “locksmiths and covert-entry specialists have known about and practiced bumping for years.”24 Public presentations in the United States are documented in 2006: Tobias’s chronology lists a HOPE conference talk with Barry Wels in New York in July 2006 and a DEF CON 14 talk with Matt Fiddler in August 2006,11 and the DEF CON 14 programme listing, for a talk on 5 August 2006, promised to “explore the vulnerabilities and exposures of virtually all pin-tumbler locks.”25 Wired reported in August 2007 that “the general public became aware of it only in the last two years after researchers disclosed the industry secret.”24

Wired described bumping as a covert technique that “leaves no obvious telltale evidence behind (though forensic examiners who scrutinize the inside of the lock might find little marks on the internal pins).”24 It also reported that at DEF CON in August 2007 a 12-year-old bumped open a Medeco Biaxial lock three times.26 In the same month Wired reported Tobias’s view that the standards did not test for bumping and said he intended to speak to the UL 437 standards technical panel that September.26 UL’s catalogue shows a lock bumping test in UL 437 effective 16 November 2015.10 More than nine years separate the documented 2006 presentations from that requirement. The catalogue gives no specimen-specific evidence about how a certification was evaluated or updated.

Medeco, 2007 and 2008

The attacks on Medeco cylinders are a well-reported case. Wired described Medeco’s patented pin tumbler locks as requiring the key both to lift each pin and to rotate it to one of three orientations.24 A 2002 Medeco patent adds to such a rotating-pin, sidebar lock a slider that normally blocks the sidebar and is moved out of the way by a rib on a specially shaped key;27 Wired described the M3 slider in similar terms.26 Tobias’s 2007 slides describe Medeco as “UL-437 and ANSI 156.30 rated and VdS,” and, according to the slides, a Medeco press release of 4 August 2006 said “Our locks are bump proof.”11

At DEF CON 15 in August 2007, three researchers led by Tobias, among them Matt Fiddler, presented methods to bump and pick Medeco Biaxial and M3 cylinders, and to get past the M3 slider. According to Wired, they had analysed Medeco’s published key codes to produce fewer than a dozen keys that fit numerous Biaxial and M3 locks. They also showed Wired a rapid bypass of Medeco’s M3 single-cylinder deadbolt that did not attack the cylinder at all, and asked that its details not be published.2624

Medeco’s response, as Wired reported it, differed by finding. Clyde Roberson, its director of technical services, “acknowledged that the researchers might be right about the deadbolt problem,” and said the company had developed what he hoped was a hardware fix, which it hoped to put on the factory floor if tests showed it worked. On bumping he was firm: “We don’t believe you can use a bump key on Biaxial or M3 (locks) at all, whether it’s with a paper clip or not. We believe that this information is factually incorrect.”24 Wired’s report does not record a specific Medeco response to the picking results. The presenters’ DEF CON 16 abstract the following year said that, as a result of their DEF CON 15 disclosures, Medeco was “forced to urgently upgrade their deadbolt locks.”28 Wired’s conditional account and the presenters’ later claim are the only public evidence here; neither establishes when or how widely a fix shipped.

A year later, at DEF CON 16 on 8 August 2008, Tobias and Fiddler presented “Open in 30 Seconds: Cracking One of the Most Secure Locks in America,” describing an eighteen-month project that produced “the ability to pick, bump, and mechanically bypass Medeco cylinders, sometimes in seconds.”28 Agence France-Presse reported that the new attack involved copying keys from a picture or photocopy, and quoted Tobias: “If you can make a key it’s over.”29

These are the researchers’ claims as reported in the press and in their own talk materials. Medeco disputed the bumping results, and Tobias’s slides themselves say “Not all but many” cylinders could be bumped, depending on factors including knowledge or simulation of the sidebar code.11 No source here establishes which ratings the attacked specimens carried. What the case does show is a type of evidence the ratings cannot provide: a cylinder family sold as high security was reported open to techniques outside the published test lists, and the reported deadbolt attack went around the cylinder.

Key control: copying from a photograph

Key control rests on the cut pattern and the blank both being hard to obtain. Research since 2008 has weakened both assumptions in tested cases. Benjamin Laxton, Kai Wang and Stefan Savage of the University of California, San Diego presented “Sneakey” at ACM CCS in October 2008. Their system extracted “a key’s complete and precise bitting code at a distance via optical decoding” from photographs. In their experiments with common residential key types, “even at a distance of 100 feet, 7 out of 10 keys were precisely decoded within the first guess,” and from the roof of their building they decoded one of two keys tried at 195 feet.30 Recovering the cut pattern is half the attack; the attacker still needs a blank that fits the keyway.

Restricted keyways answer that second half. Ben Burgess, Eric Wustrow and J. Alex Halderman of the University of Michigan tested that answer at the USENIX Workshop on Offensive Technologies in 2015. They found that “commodity 3D printers are able to produce key blanks and pre-cut keys with enough resolution to work in several commonly used pin-tumbler locks,” built a tool that generates a printable blank model “using only a single picture of a lock’s keyway,” and estimated that a printed key could be made in plastic or metal “for a reasonable cost ($10–30).” Their conclusion: “3D printing antiquates the notion that we can have physical tokens such as keys that are hard or expensive to reproduce. Current high-security locks rely on this notion.”16 Their results cover the lock systems they tested, not every restricted keyway.

The same year supplied a large-scale example. In September 2015, CAD files for the Transportation Security Administration’s master keys for “TSA-approved” luggage locks were posted online, and The Register reported that people printed keys from them and posted photos of the keys opening Travel Sentry locks, that reports pointed to “a high-resolution picture from a Washington Post story about the US Transportation Security Administration (TSA) that was published last year” as the source, and, as its own figure for potential exposure, that “more than 300 million travel locks” were affected.31

The two studies demonstrate different steps on the systems they tested: one recovers the cut pattern, the other produces a blank. Together they bear on what A156.30’s key-control category can deliver. Blank control, as BHMA describes it, restricts distribution of blanks through the manufacturer and the law; for the tested systems, the research shows ways around that restriction. ASSA ABLOY, a manufacturer, argues that patents help “both by outlawing key copying and by increasing the technical difficulty of producing key blanks”;32 how far that protection reaches depends on the patent’s claims, its term, the jurisdiction and enforcement. For the demonstrated systems, then, key control also depends on how keys are issued, carried and photographed, not only on the cylinder. In conventionally master-keyed systems, someone holding a change key and its matching lock may also be able to work out the master; that problem is covered in The master key hidden in a change key.

The opening around the cylinder

A156.2 and A156.13 test complete locks and latches, and UL 437 covers door locks as well as cylinders. Certification under these standards applies to the listed product and configuration. The installed opening, meaning the particular strike, frame and door and how well they fit, is not certified by any of them. Ray Bernard, a security consultant, wrote in 2011 about a weakness he said he had found “in every assessment for the past 15 years”: a latch bolt can be pushed back “using a screwdriver, metal ruler, plastic card, and so on” unless a deadlocking plunger holds it, and “security assessments commonly find that the strike plate is the wrong type of strike plate or the wrong size, allowing both the latch bolt and the deadlocking plunger to be fully extended.” He estimated that about 10 percent of the plungers of one type he illustrated failed in his assessments.33 A certified lock fitted with the wrong strike is still certified.

Standards for whole openings do exist. ASTM F476 covers “door assemblies of various materials and types of construction,” including “individual components such as the hinge, lock, door, strike, and jamb,” and is “designed to measure the capability of a swinging door assembly to restrain or delay and frustrate the commission of ‘break-in’ crimes.”34 A cylinder’s UL 437 listing says nothing about how the opening would fare under such a test.

Some government guidance takes a similar systems view for its own applications. The DoD Lock Program’s page on high-security padlocks, which it says are intended for general military use with high-security hasps under DoD Manual 5100.76, names MIL-DTL-43607J for the padlock and a separate specification, MIL-DTL-29181D, for the hasp, and states that keys for the specified padlock are limited to “one control key and two operating keys.”35 In that application the padlock is specified together with the hardware it hangs on, and the key count is part of the requirement.

The electronic side

Electromechanical cylinders and electronic locks add attack surfaces that mechanical tests do not reach. A156.30 includes electrical resistance tests (over-voltage, electrostatic discharge, magnets, conductive liquids); they already appear in the 2014 committee copy,13 and the 2025 summary lists them under surreptitious tests, with audit trails and time zoning under key control.15 The public summary establishes those tests and management attributes, not any wider review of a lock’s protocol or design. In 2012, Cody Brocious presented a talk at Black Hat USA on Onity hotel locks, which his abstract said were installed in “Nearly ten million” doors and were “insecure by design,” with “critical, unpatchable vulnerabilities.”36 The abstract says nothing about the locks’ certifications. The case, as the speaker presented it, illustrates a class of failure in a lock’s electronics that a timed mechanical test is not designed to find. Credential cloning is treated separately in Cloning the badge.

How other regimes write the attacker down

European cylinder grading

The European standard EN 1303 encodes its results in a string of grades rather than a single one. BSI’s page for the 2015 edition described it as establishing “one category of use, three grades of durability, three grades for fire and four grades corrosion resistance all based on performance tests as well as six grades of key-related security based on design requirements and five grades on performance tests that simulate an attack,” classified “in accordance with the eight-digit coding system” (the positions hold letters as well as numbers).37 The current edition, BS EN 1303:2026, published on 31 August 2026, extends the title to “Cylinders and Master-Key-Systems (MKS)” and adds “two grades for mechanical coding (single cylinders and MKS).”38 ASSA ABLOY’s guide warns that “Compliance with EN 1303 doesn’t automatically indicate a high security standard: Precise gradings are decisive.”32 The design is close in spirit to A156.30: key-related security and attack resistance are graded separately, so a buyer can see that a cylinder is strong against attack but weak on key security. Mechatronic cylinders have their own standard, EN 15684, covering “Mechatronic Cylinders and their keys and/or electronic keys”; its current edition was published in 2020.39

A government specification that states its attacker

FF-P-110J, the federal specification for changeable-combination padlocks dated 11 February 1997, is unusually explicit about its scope. DLA’s ASSIST record lists it with a 2004 amendment and validation notices up to December 2022.40 “The padlocks are not tested for forced opening,” the specification says, although its test schedule still includes tension, jar, shackle-strength and drop tests; its notes describe the intended use as “low level resistance to forced entry and high level tell-tale manipulation or surreptitious action.” The requirement: “Class 1 and 2 padlocks shall resist opening for not less than 30 man-minutes by manipulation and 10 man-minutes by surreptitious attack.”41 The 1997 text also defined Class 1 by “Thirty minutes resistance to opening by radiographic techniques”; Amendment 1 of 20 January 2004 deleted the radiographic requirement and its test, without changing that class wording.4142

The specification defines its attacks in detail, and differently for each. In the manipulation test, “each technique may be applied for the full net working time, using the human senses amplified as necessary to unlimited types of mechanical, electric, electronic, and magnetic equipment,” within stated limits on the size and weight of the equipment carried. In the surreptitious test, tools are “limited to those powered by hand,” heat above 300 °F is excluded, “There shall be no limitations on the time required for exploration and preparation for the test,” and the net working time includes “time expended for any masking or repair of damage to the lock that may become necessary to obliterate evidence of penetration.” Surreptitious attack is defined as opening and closing the padlock “in such a manner or by such a means as to leave no evidence of the act which would be readily discernible in normal use.” Time is counted in man-minutes: “Time expended times the number of men engaged in the test.”41

The specification thus names the threat it addresses (undetected opening), and its strength tests are not a forced-entry rating. Its evidence and time criteria apply to the tests it defines. A specifier choosing commercial hardware has to make the same kind of decision about which threat matters, and the place to make it is a design-basis threat of the kind described in How a facility’s security is decided.

What a specifier can and cannot infer

A BHMA grade with a directory listing says that a product family including that model passed the grade’s cycle, operating, strength and finish tests in a designated lab, and that the family is retested within a four-year cycle and subject to factory audit.19 A grade alone does not establish pick resistance or key control; an A156.5 suffix A indicates that a cylinder met UL 437’s drilling and picking requirements, without itself being a UL listing.86

A UL 437 certification says that the product passed the attack tests that apply to its class, and that UL inspects production for continued conformity.922 On the public evidence it does not establish key control, and it says nothing about the installed opening; a bumping requirement exists only from 16 November 2015.10

An A156.30 level code gives the weakest level reached in each of three categories, including key control.15 It does not tell you which letter is best without the edition’s own definition, and for the systems tested in the research it does not show that key control will survive photographs and 3D printing.1316

A phrase like “meets Grade 1” without a listing leaves BHMA certification unverified, whatever test reports may exist; ask BHMA.2119

None of them says how long the door will hold. The tests measure laboratory resistance of one product, while an attacker at a real door chooses the weakest of cylinder, latch, strike, frame, hinges, glazing and the people who hold keys.

What to do differently

  1. Verify the exact model, edition and scope in one pass. Find the model and configuration in the BHMA directory or UL Product iQ; get the edition or revision and the tests that applied from the listing, the certification documents or the certifier; and verify certification through an exact listing or directly with the certifier.20232119 For a UL 437 product, ask whether the bumping test in force from 16 November 2015 applied.10
  2. Write the definitions into the specification. Name the edition of A156.30, state in words what each required level means, and specify each of the three categories separately, because each is set by its weakest feature and BHMA’s own summaries conflict on whether A or C is highest.1513
  3. Ask for the right designation. A grade measures durability, operation and strength; if pick and drill resistance matter, specify the A156.5 drill-and-pick designation or verify that the applicable UL 437 certification or A156.30 levels cover both tests.841015
  4. Treat key control as a process. Restrict who photographs keys and keyways, keep master keys out of sight and out of publications, and do not rely on restricted blanks alone where an attacker could photograph the keyway and print a blank.301631 Where it suits the application, write key counts into the requirement, as the DoD Lock Program’s padlock guidance does.35
  5. Specify the opening. Require correct strikes and working deadlocking latches, and consider whole-assembly testing such as ASTM F476 for doors that matter.3334
  6. Match hardware and testing to the facility. Choose hardware against the standard that applies to the facility and its design-basis threat, and for high-value doors commission an attack assessment against the threats in your design basis, including bolt-mechanism bypass and electronic failure where relevant to the opening; the Medeco deadbolt and Onity cases are examples.2636

Conclusion

Each of these ratings is an honest answer to a narrow question, asked of one product in a laboratory installation under rules fixed when the edition was written. That makes results comparable within a standard and edition, and it means the tests can lag behind new attacks and say nothing about the opening a buyer actually installs. Bumping was presented publicly in 2006, and UL 437’s bumping test took effect in 2015. One study decoded cuts from key photographs, and another reproduced restricted blanks on the systems it tested. BHMA’s own summaries give inconsistent signals about the A156.30 hierarchy. The practical consequence is procedural. A specifier should verify the exact model and applicable edition through the listing, certification documentation or certifier, write the meaning of each required level into the contract, and treat everything the rating does not cover (the strike, the frame, the electronics, and who holds and photographs the keys) as their own responsibility, judged against the threat the building actually faces.

Footnotes

  1. Builders Hardware Manufacturers Association, “Product Grade Levels,” accessed 27 November 2026. https://buildershardware.com/ANSI-BHMA-Standards/Product-Grade-Levels (opens in a new tab) ↩
  2. Builders Hardware Manufacturers Association, “A156.2 - 2022 Locks and Latches” (Hardware Highlights for ANSI/BHMA A156.2-2022, Bored and Preassembled Locks and Latches), accessed 27 November 2026. https://buildershardware.com/ANSI-BHMA-Standards/Hardware-Highlights/A1562-2022-Locks-and-Latches (opens in a new tab) ↩1 ↩2 ↩3 ↩4
  3. Builders Hardware Manufacturers Association, “A156.13 - 2022 Mortise Locks” (Hardware Highlights for ANSI/BHMA A156.13-2022), accessed 27 November 2026. https://buildershardware.com/ANSI-BHMA-Standards/Hardware-Highlights/A15613-2022-Mortise-Locks (opens in a new tab) ↩1 ↩2 ↩3 ↩4
  4. Builders Hardware Manufacturers Association, “A156.5 - 2020 Cylinders and Input Devices for Locks” (Hardware Highlights), accessed 27 November 2026. https://buildershardware.com/ANSI-BHMA-Standards/Hardware-Highlights/A1565-2020-Cylinders-and-Input-Devices-for-Locks (opens in a new tab) ↩1 ↩2 ↩3 ↩4 ↩5
  5. Allegion, “Understanding BHMA grading & testing,” Industry Insights, document 009968, Rev. 12/06/2013. https://dev-cs-schlage-commercial.allegion.com/content/dam/allegion-us-2/web-files/allegion/information-documents/Understanding_BHMA_Grading_and_Testing_009968.pdf (opens in a new tab) ↩1 ↩2 ↩3 ↩4
  6. Builders Hardware Manufacturers Association, “ANSI/BHMA A156.5 Cylinders and Input Devices for Locks” (posted text of ANSI/BHMA A156.5-2014, Sections 1.1 to 1.7, approved 24 January 2014), Home Sweet Secure Home. https://buildershardware.com/Home-Sweet-Secure-Home/ansibhma-a1565-cylinders-and-input-devices-for-locks (opens in a new tab) ↩1 ↩2 ↩3 ↩4
  7. Builders Hardware Manufacturers Association, “ANSI/BHMA A156.30 High Security Cylinders Product” (posted text of ANSI/BHMA A156.30-2014, Sections 1.1 to 1.3.2, approved 15 August 2014), Home Sweet Secure Home, 1 April 2019. https://buildershardware.com/Home-Sweet-Secure-Home/ansibhma-a15630-high-security-cylinders-product (opens in a new tab) ↩1 ↩2 ↩3 ↩4
  8. Builders Hardware Manufacturers Association, ANSI/BHMA A156.5-2014, American National Standard for Cylinders and Input Devices for Locks, committee review copy, Section 4.5 (suffix A) and Section 6.6.6. https://buildershardware.com/LinkClick.aspx?fileticket=tx6m6DzbtCo%3D&portalid=0 (opens in a new tab) ↩1 ↩2 ↩3
  9. UL Standards & Engagement, “UL 437 Key Locks,” product record (edition 8; last revision and ANSI approval 31 January 2023; summary of topics), accessed 27 November 2026. https://www.shopulstandards.com/ProductDetail.aspx?UniqueKey=25916 (opens in a new tab) ↩1 ↩2
  10. UL, “UL 437 Standard for Key Locks,” Standards Catalog (edition 8, edition date 15 May 2013; scope and table of contents), Internet Archive capture of 14 November 2019. https://web.archive.org/web/20191114063244/https://standardscatalog.ul.com/standards/en/standard_437_8 (opens in a new tab) ↩1 ↩2 ↩3 ↩4 ↩5 ↩6 ↩7 ↩8
  11. Marc Weber Tobias, “High Insecurity Locks: What you Need to Know about Locks, Lies, and Liability,” slides, HITBSecConf2007, Kuala Lumpur, September 2007 (UL-437 attack-resistance table, A156.30 levels, Medeco chronology). https://archive.conference.hitb.org/hitbsecconf2007kl/materials/D1T1%20-%20Marc%20Weber%20Tobias%20-%20%20High%20Security%20Locks%20-%20Illusion%20or%20Reality.pdf (opens in a new tab) ↩1 ↩2 ↩3 ↩4 ↩5 ↩6
  12. “UL 437,” Lockwiki, last edited 20 August 2009 (secondary summary of door-lock attack times and differs). https://lockwiki.com/index.php/UL_437 (opens in a new tab) ↩1 ↩2
  13. Builders Hardware Manufacturers Association, ANSI/BHMA A156.30-2014, American National Standard for High Security Cylinders, committee review copy, Sections 5 to 8 (key control, destructive tests including 6.4 drill resistance, surreptitious and electrical tests including 7.4, Section 8 identifying numbers). https://buildershardware.com/LinkClick.aspx?fileticket=N3PWlIyINnU%3D&portalid=0 (opens in a new tab) ↩1 ↩2 ↩3 ↩4 ↩5 ↩6 ↩7 ↩8 ↩9
  14. BHMA Certificate of Compliance for BEST, A156.30 High Security Cylinders, downloaded from the BHMA Certified Product Directory and printed 7 March 2022 (hosted by dormakaba support). https://dhwsupport.dormakaba.com/hc/article_attachments/4561107345563/BHMA_CPD_BEST_A15630HighSecurityCylinders_3-7-2022.pdf (opens in a new tab) ↩1 ↩2 ↩3 ↩4
  15. Builders Hardware Manufacturers Association, “A156.30 - 2025 High Security Cylinders” (Hardware Highlights), accessed 27 November 2026. https://buildershardware.com/ANSI-BHMA-Standards/Hardware-Highlights/A15630-2025-High-Security-Cylinders (opens in a new tab) ↩1 ↩2 ↩3 ↩4 ↩5 ↩6 ↩7 ↩8 ↩9 ↩10 ↩11 ↩12 ↩13
  16. Ben Burgess, Eric Wustrow and J. Alex Halderman, “Replication Prohibited: Attacking Restricted Keyways with 3D-Printing,” 9th USENIX Workshop on Offensive Technologies (WOOT 15), 2015 (abstract, Section 6 and conclusion). https://files.usenix.org/s3fs-public/cdn/woot15-paper-burgess.pdf (opens in a new tab) ↩1 ↩2 ↩3 ↩4
  17. Builders Hardware Manufacturers Association, “A156.30 High Security Cylinders” (Hardware Highlights PDF, 2020). https://buildershardware.com/Portals/0/156_30%20HH%202020.pdf?ver=2020-06-17-203731-760 (opens in a new tab) ↩
  18. Builders Hardware Manufacturers Association, “How to Certify Your Product,” accessed 27 November 2026. https://buildershardware.com/Certification-Program/How-to-Certify-Your-Product (opens in a new tab) ↩
  19. Builders Hardware Manufacturers Association, BHMA Certification Operational Manual, January 2024, Sections 20.1 to 20.16 and Schedule 1. https://buildershardware.com/Portals/0/BHMA%20Certification%20Operational%20Manual%20-%20Jan%202024%20Final.pdf?ver=2024-02-26-102350-590 (opens in a new tab) ↩1 ↩2 ↩3 ↩4 ↩5 ↩6 ↩7
  20. Builders Hardware Manufacturers Association, “Certified Products Directory,” accessed 27 November 2026. https://buildershardware.com/Certification-Program/Certified-Products-Directory (opens in a new tab) ↩1 ↩2
  21. Builders Hardware Manufacturers Association, “Labeling Compliance,” accessed 27 November 2026. https://buildershardware.com/Certification-Program/Labeling-Compliance (opens in a new tab) ↩1 ↩2 ↩3
  22. UL Solutions, “Follow-Up Services: Ongoing Onsite Certification Inspections,” accessed 27 November 2026. https://www.ul.com/services/follow-services (opens in a new tab) ↩1 ↩2
  23. UL Solutions, “Product iQ: Product Sourcing and Certifications Database,” accessed 27 November 2026. https://www.ul.com/software/product-sourcing-and-certifications-database (opens in a new tab) ↩1 ↩2
  24. Kim Zetter, “Medeco Readies Assembly-Line Fix for DefCon Lock Hack,” Wired, 9 August 2007, as reposted to the InfoSec News mailing list, 10 August 2007. https://seclists.org/isn/2007/Aug/19 (opens in a new tab) ↩1 ↩2 ↩3 ↩4 ↩5 ↩6
  25. Matt Fiddler and Marc Weber Tobias, “Things That Go ‘Bump’ in the night: An Analysis of Current and Emerging Threats to Physical Security,” DEF CON 14, 5 August 2006 (InfoconDB listing with abstract). https://infocondb.org/con/def-con/def-con-14/things-that-go-bump-in-the-night-an-analysis-of-current-and-emerging-threats-to-physical-security (opens in a new tab) ↩
  26. Kim Zetter, “White House High-Security Locks Broken: Bumped and Picked at DefCon,” Wired, 5 August 2007, as reposted to the InfoSec News mailing list, 9 August 2007. https://seclists.org/isn/2007/Aug/6 (opens in a new tab) ↩1 ↩2 ↩3 ↩4 ↩5
  27. Peter H. Field and Andy E. Perkins (Medeco Security Locks, Inc.), “Rotating pin tumbler side bar lock with side bar control,” US Patent 6,477,875 B2, filed 19 October 2001, issued 12 November 2002 (abstract). https://patents.google.com/patent/US6477875B2/en (opens in a new tab) ↩
  28. Matt Fiddler and Marc Weber Tobias, “Open in 30 Seconds: Cracking One of the Most Secure Locks in America,” DEF CON 16, 8 August 2008 (InfoconDB listing with abstract). https://infocondb.org/con/def-con/def-con-16/open-in-30-seconds-cracking-one-of-the-most-secure-locks-in-america (opens in a new tab) ↩1 ↩2
  29. Agence France-Presse, “Cracking top-rated locks is child’s play: experts,” Taipei Times, 12 August 2008, p. 7. https://www.taipeitimes.com/News/world/archives/2008/08/12/2003420068 (opens in a new tab) ↩
  30. Benjamin Laxton, Kai Wang and Stefan Savage, “Reconsidering Physical Key Secrecy: Teleduplication via Optical Decoding,” ACM CCS 2008, Alexandria, Virginia, 27–31 October 2008 (abstract and Section 4). https://vision.ucsd.edu/sites/default/files/publications/pdfs/Reconsidering%20Physical%20Key%20Secrecy%20Teleduplication%20via%20Optical%20Decoding.pdf (opens in a new tab) ↩1 ↩2
  31. Kieren McCarthy, “3D printer blueprints for TSA luggage-unlocking master keys leak online,” The Register, 10 September 2015. https://www.theregister.com/2015/09/10/tsa_master_key_blueprints_leaked/ (opens in a new tab) ↩1 ↩2
  32. ASSA ABLOY, “Standards and patent protection for mechanical cylinders,” Access Stories, 6 February 2024. https://www.assaabloy.com/si/si/stories/access-stories/standards-and-patent-protection-for-mechanical-cylinders (opens in a new tab) ↩1 ↩2
  33. Ray Bernard, “The Deadlocking Plunger Weakness,” SecurityInfoWatch, 28 September 2011. https://www.securityinfowatch.com/home/article/10374064/the-deadlocking-plunger-weakness (opens in a new tab) ↩1 ↩2
  34. ASTM International, “ASTM F476-23, Standard Test Methods for Security of Swinging Door Assemblies,” scope, ASTM store page. https://store.astm.org/f0476-23.html (opens in a new tab) ↩1 ↩2
  35. DoD Lock Program, Naval Facilities Engineering and Expeditionary Warfare Center, “High Security Padlocks,” Internet Archive capture of 5 January 2026. https://web.archive.org/web/20260105142312/https://exwc.navfac.navy.mil/DoD-Lock-Program/Security-Hardware/High-Security-Padlocks/ (opens in a new tab) ↩1 ↩2
  36. Cody Brocious, “My Arduino Can Beat Up Your Hotel Room Lock,” Black Hat USA 2012 (InfoconDB listing with abstract). https://infocondb.org/con/black-hat/black-hat-usa-2012/my-arduino-can-beat-up-your-hotel-room-lock (opens in a new tab) ↩1 ↩2
  37. BSI Knowledge, “BS EN 1303:2015 Building hardware. Cylinders for locks. Requirements and test methods” (published 30 June 2015, withdrawn 17 August 2026). https://knowledge.bsigroup.com/products/building-hardware-cylinders-for-locks-requirements-and-test-methods (opens in a new tab) ↩
  38. BSI Knowledge, “BS EN 1303:2026 Building hardware. Cylinders and Master-Key-Systems (MKS) for locks. Requirements and test methods” (published 31 August 2026), accessed 27 November 2026. https://knowledge.bsigroup.com/products/building-hardware-cylinders-and-master-key-systems-mks-for-locks-requirements-and-test-methods (opens in a new tab) ↩
  39. BSI Knowledge, “BS EN 15684:2020 Building hardware. Mechatronic cylinders. Requirements and test methods” (published 30 November 2020), accessed 27 November 2026. https://knowledge.bsigroup.com/products/building-hardware-mechatronic-cylinders-requirements-and-test-methods-1 (opens in a new tab) ↩
  40. Defense Logistics Agency, ASSIST QuickSearch, “FF-P-110” document details (revision history: Revision J, 11 February 1997; Amendment 1, 20 January 2004; validation notices to 12 December 2022), data updated 25 November 2026. https://quicksearch.dla.mil/qsDocDetails.aspx?ident_number=49886 (opens in a new tab) ↩
  41. General Services Administration, Federal Specification FF-P-110J, “Padlock, Changeable Combination (Resistant to Opening by Manipulation and Surreptitious Attack),” 11 February 1997, Sections 1.1 and 1.2 (classes), 3.8, 4.6.2 (Table II), 4.6.3 and 6 (copy hosted by MBA USA). https://mbausa.com/content/downloadfiles/Federal_Specifications/FF-P-110J.pdf (opens in a new tab) ↩1 ↩2 ↩3
  42. General Services Administration, FF-P-110J Amendment 1, 20 January 2004 (deletes 3.9, 3.9.1, 4.6.3.3 and 6.4.4), DoD Lock Program copy, Internet Archive capture of 15 February 2026. https://web.archive.org/web/20260215052716/https://exwc.navfac.navy.mil/Portals/88/Documents/EXWC/DoD_Locks/PDFs/FF-P-110_A1.pdf (opens in a new tab) ↩